Description

The Siemens 6AV7612-0AE32-0AF0 is a SIMATIC Panel PC 670, designed for industrial human-machine interface (HMI) applications. This unit features a 12-inch TFT touch display, providing an interactive interface for operators. It comes with a standard configuration including a 40 GB hard drive, 256 MB of RAM, and is powered by a Pentium III 500 MHz CPU. The Panel PC operates on a 24 V DC power supply and is pre-installed with Windows 98 English, making it suitable for integration into existing industrial control systems requiring this specific operating environment.

Features

  • 12-inch TFT Touch Display
  • Pentium III 500 MHz CPU
  • 256 MB RAM
  • 40 GB Hard Drive
  • 24 V DC Power Supply
  • Pre-installed with Windows 98 English

Applications

The Siemens SIMATIC Panel PC 670 is typically deployed in industrial environments for:

  • Machine operation and control
  • Process visualization and monitoring
  • Data acquisition and display
  • HMI for automation systems
  • Integration into existing control cabinets and panels

Technical Specifications

Parameter Value
Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Product Type PC Panel
Display Type 12" TFT Touch Display
CPU Pentium III 500 MHz
RAM 256 MB
Hard Drive 40 GB
Power Supply 24 V DC
Operating System Windows 98 English
Product Phase Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. De-energize System: Ensure all power to the control cabinet or panel is disconnected before beginning installation.
  2. Mounting: Securely mount the Panel PC into the designated panel cutout. Ensure proper sealing to maintain the enclosure's IP rating.
  3. Power Connection: Connect the 24 V DC power supply to the appropriate terminals, observing correct polarity. Verify the power source meets the specified voltage and current requirements.
  4. Grounding: Establish a robust protective earth (PE) connection to the chassis of the Panel PC to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any required peripherals such as keyboards, mice, or network cables to the available ports.
  6. Cable Management: Route all cables to prevent strain, interference, and damage. Use cable ties and conduits where appropriate.
  7. Environmental Considerations: Ensure the installation location provides adequate ventilation and operates within the specified temperature and humidity ranges for the device.
  8. Power Up: After all connections are verified, re-energize the system and observe the Panel PC's startup sequence.

FAQ

What is the primary function of the Siemens 6AV7612-0AE32-0AF0?

It functions as an industrial Human-Machine Interface (HMI) for process visualization, monitoring, and control within automation systems.

What operating system is pre-installed on this Panel PC?

The Panel PC comes with Windows 98 English pre-installed.

What are the power supply requirements for the SIMATIC Panel PC 670?

It requires a 24 V DC power supply.

What display technology does this unit utilize?

It features a 12-inch TFT touch display.

Is this product considered current or obsolete?

According to the product phase information, this model is classified as obsolete.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...