Triconex 3703E Tricon Isolated Analog Input Module
SKU 3703E
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
Triconex
Product No.:
3703E
Country of origin:United States
Product Type:
Isolated Analog Input Modules
Payment:
T/T, Western Union
Weight:
2700g
Dimensions:
305 mm x 280 mm x 30 mm
Shipping port:
Xiamen
Warranty:
12 months
Description
The Triconex 3703E is a highly reliable Isolated Analog Input Module designed specifically for Tricon systems. As a core component of Safety Instrumented Systems (SIS), this module features three independent input channels to perform high-accuracy signal acquisition from field sensors using Triple Modular Redundancy (TMR) architecture. The Triconex 3703E supports 0-5 VDC or 0-10 VDC differential isolated signal inputs, which are software-configurable via TriStation 1131. Each channel provides independent signal conditioning and opto-isolation between the field and the system, effectively preventing a single-channel failure from affecting other channels. The module utilizes a built-in Mid-Value Selection algorithm to vote on the three sets of acquired data, ensuring the highest data integrity, functional safety, and continuous system availability in critical industrial protection applications.
Features
Utilizes Triple Modular Redundancy (TMR) architecture with three completely independent input channels.
Supports 16-point differential isolated analog inputs, providing up to 200V peak channel-to-channel isolation.
Input voltage ranges are configurable via TriStation 1131 software for 0-5 VDC or 0-10 VDC (including a +6% overrange capability).
Features comprehensive, continuous online self-diagnostics to monitor channel operational status in real time.
Supports Hot-Spare functionality, allowing replacement of faulty modules while the system is online without interrupting the process.
Mechanically keyed design prevents incorrect insertion into the chassis slots.
Applications
Emergency Shutdown Systems (ESD)
Fire and Gas Detection Systems (F&G)
Boiler and Burner Management Systems (BMS)
High-reliability control for steam turbines and large rotating machinery
Safety parameter monitoring in critical process industries
Technical Specifications
Parameter
Value
Manufacturer
Triconex (Invensys)
Model Number
3703E
Module Type
TMR, Analog Input (AI)
Number of Input Points
16, differential, isolated
Isolated Points
Yes
Input Range
0-5 VDC or 0-10 VDC (selected via TriStation 1131)
Input Update Rate
50 ms
Resolution
12 bits
Accuracy
< 0.15% of FSR, from 0 to 60 °C
Input Resistance (Load)
30 MΩ (DC) minimum
Power-Off Resistance
30 MΩ (DC) minimum
Common Mode Rejection
-90 dB @ 60Hz minimum, -100 dB @ DC minimum
Common Mode Range
+200V peak
Leg-to-Leg Isolation
20 kΩ typical
Normal Mode Rejection
-3 dB @ 8Hz, -17 dB @ 60Hz, -23 dB @ 120Hz
Input Overrange Protection
150 VDC / 115 VAC continuous
Weight
4.7 to 6.0 lbs. (2.1 kg to 2.7 kg)
Dimensions
Standard Tricon I/O slot format
Operating Temperature
0 to 60 °C ambient (measured at chassis bottom)
Storage Temperature
-40 to 75 °C
Relative Humidity
5% to 95% non-condensing
Installation Guidelines
Chassis Slot Positioning: The module features a mechanically keyed design to ensure proper insertion into the designated Tricon chassis slot. Push the module smoothly into place and securely tighten the retention screws.
External Wiring Network: Connection must be made via a dedicated External Termination Panel (ETP), which interfaces with the Tricon chassis backplane using standard interface cables.
Hot-Spare Configuration: To enable Hot-Spare functionality, an identical backup module can be installed in the adjacent empty slot. The system will automatically execute a bumpless online switchover if a primary module fault is detected.
Environmental Protection: Since Tricon systems do not offer special protection against dust or corrosive atmospheres, the module must be installed within an industrial control enclosure that meets NEMA protection rating standards.
Compliance and Certifications
TÜV Rheinland: Certified for SIL 1-3 applications (in compliance with IEC 61508 safety requirements), EN 54 (fire and gas detection standard), and NFPA 72/8501/8502.
CSA: Complies with North American electrical safety standards and is approved for use in designated jurisdictions.
Factory Mutual (FM): Suitable for Class I, Division 2, Temperature T4, Groups A, B, C, D hazardous indoor locations (or outdoor enclosures meeting NEMA 4 requirements).
CE Mark: Complies with the EU EMC Directive (89/336/EEC) and Low Voltage Directive (72/23/EEC).
U.S. NRC: Certified by the U.S. Nuclear Regulatory Commission (NRC) for use in nuclear Class 1E safety control applications.
FAQ
What is the primary function of the isolation on the Triconex 3703E module?
The module features optocoupled isolation between individual channels and system logic, protecting internal processors from high common-mode field voltages up to 200V peak and eliminating potential ground loops.
How are current signals (0-20 mA) accommodated by the 3703E?
Current loops are supported using external shunt resistors: a 250 ohm shunt is utilized for 5V conversion, and a 500 ohm shunt is utilized for 10V conversion.
What is the input update rate of the 3703E analog input?
The input update rate is a rapid 50 milliseconds, allowing safety-critical architectures to capture process variables quickly and reliably.
A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.
A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.
A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.
A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.
Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...