Description

The UR 7BH (also identified as UR-7BH) is a dedicated fiber-optic communication interface module manufactured by General Electric for the Multilin Universal Relay series protection and control platform. This module serves as a localized data transmission interface, enabling high-speed optical communications across industrial networks and substation environments. Equipped with a single-channel Edge-Emitting LED (ELED) transmitter operating at a nominal wavelength of 1300 nm, the UR 7BH is designed specifically for multi-mode fiber infrastructure. The horizontal chassis form factor, denoted by the "H" configuration suffix, allows seamless integration into horizontal UR relay slots to maintain deterministic data flow and system synchronization.

Features

  • Features a single-channel 1300 nm ELED optical transmitter configuration.
  • Designed specifically for multi-mode fiber-optic network communication architecture.
  • Integrated into the horizontal ("H") form factor for standard Universal Relay enclosures.
  • Provides high-speed data transmission path directly linked over the internal chassis backplane.
  • Delivers robust optical isolation against high-voltage electrical surges and EMI/RFI noise.

Applications

  • High-speed peer-to-peer communication between Universal Relay protection nodes.
  • Fiber-optic SCADA and substation automation network connectivity.
  • Long-distance, noise-immune communication linkages within power generation plants and industrial facilities.

Technical Specifications

Parameter Specification
Model Number UR 7BH (UR-7BH)
Product Type Communication Module (COMMS 7B)
Manufacturer GE Multilin
Wavelength 1300 nm
Fiber Type Multi-mode
Optical Source ELED, 1 Channel
Chassis Orientation Horizontal

Installation Guidelines

  • Chassis Power Down: Turn off all control voltage sources feeding the Universal Relay frame prior to handling the module to protect internal backplane chipsets.
  • Fiber Optic Care: Maintain the minimum bending radius of the multi-mode fiber patch cables to minimize attenuation. Clean the fiber ferrule tips and optical transceiver ports with lint-free wipes before connection.
  • Module Seating: Align the horizontal module carefully inside the chassis tracks, sliding it smoothly into place until the rear contact pin block locks tightly into the active backplane.
  • Network Mapping: Utilize the EnerVista UR utility program to verify device detection and map communication variables to the specific slot where the module is housed.

FAQ

What type of optical fiber infrastructure is required for this module?

This module requires multi-mode fiber-optic cabling and operates at a nominal wavelength of 1300 nm.

What kind of light source does the transmitter use?

The module utilizes a 1-channel Edge-Emitting Light Emitting Diode (ELED) as its primary optical transmitter source.

Does this module require manual dip-switch network configurations upon installation?

No, hardware routing and network logic parameters are completely assigned via software using the EnerVista UR interface suite once the unit is seated in the chassis slot.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...