General Electric

UR7BH GE Multilin UR-7BH Universal Relay Communication Module

SKU UR-7BH

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: UR-7BH

  • Country of origin:United States

  • Product Type: Communication Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 660g

  • Dimensions: 16.3cm x 4.2cm x 21cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The UR 7BH (also identified as UR-7BH) is a dedicated fiber-optic communication interface module manufactured by General Electric for the Multilin Universal Relay series protection and control platform. This module serves as a localized data transmission interface, enabling high-speed optical communications across industrial networks and substation environments. Equipped with a single-channel Edge-Emitting LED (ELED) transmitter operating at a nominal wavelength of 1300 nm, the UR 7BH is designed specifically for multi-mode fiber infrastructure. The horizontal chassis form factor, denoted by the "H" configuration suffix, allows seamless integration into horizontal UR relay slots to maintain deterministic data flow and system synchronization.

Features

  • Features a single-channel 1300 nm ELED optical transmitter configuration.
  • Designed specifically for multi-mode fiber-optic network communication architecture.
  • Integrated into the horizontal ("H") form factor for standard Universal Relay enclosures.
  • Provides high-speed data transmission path directly linked over the internal chassis backplane.
  • Delivers robust optical isolation against high-voltage electrical surges and EMI/RFI noise.

Applications

  • High-speed peer-to-peer communication between Universal Relay protection nodes.
  • Fiber-optic SCADA and substation automation network connectivity.
  • Long-distance, noise-immune communication linkages within power generation plants and industrial facilities.

Technical Specifications

Parameter Specification
Model Number UR 7BH (UR-7BH)
Product Type Communication Module (COMMS 7B)
Manufacturer GE Multilin
Wavelength 1300 nm
Fiber Type Multi-mode
Optical Source ELED, 1 Channel
Chassis Orientation Horizontal

Installation Guidelines

  • Chassis Power Down: Turn off all control voltage sources feeding the Universal Relay frame prior to handling the module to protect internal backplane chipsets.
  • Fiber Optic Care: Maintain the minimum bending radius of the multi-mode fiber patch cables to minimize attenuation. Clean the fiber ferrule tips and optical transceiver ports with lint-free wipes before connection.
  • Module Seating: Align the horizontal module carefully inside the chassis tracks, sliding it smoothly into place until the rear contact pin block locks tightly into the active backplane.
  • Network Mapping: Utilize the EnerVista UR utility program to verify device detection and map communication variables to the specific slot where the module is housed.

FAQ

What type of optical fiber infrastructure is required for this module?

This module requires multi-mode fiber-optic cabling and operates at a nominal wavelength of 1300 nm.

What kind of light source does the transmitter use?

The module utilizes a 1-channel Edge-Emitting Light Emitting Diode (ELED) as its primary optical transmitter source.

Does this module require manual dip-switch network configurations upon installation?

No, hardware routing and network logic parameters are completely assigned via software using the EnerVista UR interface suite once the unit is seated in the chassis slot.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.