Managing deterministic data distribution across harsh manufacturing environments is the primary function of the Weidmuller 1504370000 IE-SW-VL05M-3TX-2ST managed industrial Ethernet switch. This high-performance network node integrates copper and fiber interfaces to bridge long-distance field segments while maintaining robust electromagnetic immunity. Encased in a rugged metal housing, it provides reliable Store and Forward data switching for time-critical automation architectures.

Key Features

  • Managed Network Control: Comprehensive configuration options for traffic prioritization, VLAN segmentation, and ring redundancy.
  • Hybrid Port Configuration: Features 3 RJ45 Fast Ethernet ports and 2 Multimode fiber ports with ST-Duplex connectors.
  • Extended Optical Range: Supports reliable fiber optic transmission distances up to 5 km.
  • Power Redundancy: Dual redundant 12/24/48 V DC power inputs ensure continuous operation during primary supply failures.
  • Industrial-Grade Build: IP30-rated metal chassis designed to withstand high mechanical vibration and thermal stress.

Heavy Industrial Applications

  • Wind Power Generation: Linking nacelle control systems to ground-level SCADA networks over optical fiber.
  • Water and Wastewater Treatment: Connecting distributed PLC nodes across large physical footprints without electromagnetic interference.
  • Oil and Gas Processing: Safe deployment in control cabinets requiring robust thermal management and redundant power feeds.
  • Factory Automation: High-speed machine-to-machine (M2M) communication on standard DIN rail assemblies.

Technical Specifications

Parameter Specification Value
Manufacturer Weidmuller
Model Number IE-SW-VL05M-3TX-2ST
Article Number / SKU 1504370000
Switch Type Managed
Transmission Speed 100 Mbps (Fast Ethernet)
RJ45 Ports 3x 10/100BaseT(X)
Fiber Ports 2x Multimode (ST-Duplex)
Typical Fiber Distance 5 km
MAC Table Size 2 K
Packet Buffer Size 1 Mbit
Supply Voltage 12 / 24 / 48 V DC (Redundant Inputs)
Connection Interface 1x Removable 6-pin terminal block
Housing Material Metal (IP30 Protection)
Mounting Options DIN rail, Panel (with optional mounting kit)
Operating Temperature -10 degC to 60 degC
Storage Temperature -40 degC to 85 degC
Ambient Humidity 5% to 95% (non-condensing)
Dimensions (W x H x D) 53.6 mm x 135 mm x 105 mm
Net Weight 650 g
Shipping Weight 1.5 kg

Terminal Block Pin Assignment

Pin Number Signal Designation Functional Description
1 V1+ Primary DC Power Input (+)
2 V1- Primary DC Power Input (-)
3 Fault Relay Contact (Normally Closed on failure)
4 Fault Relay Contact (Normally Closed on failure)
5 V2+ Secondary Redundant DC Power Input (+)
6 V2- Secondary Redundant DC Power Input (-)

Empirical Engineering Insights

Alternative Models & Compatibility

The IE-SW-VL05M-3TX-2ST managed switch is a direct functional upgrade over unmanaged variants such as the IE-SW-VL05-3TX-2ST. When replacing an unmanaged switch with this managed unit, network administrators must configure the IP address and disable unused protocols to prevent broadcast storms. Ensure that the remote fiber transceiver matches the 1300 nm wavelength specification of this device's multimode ST ports.

Application Pitfalls & Engineering Notes

In high-temperature environments exceeding 50 degC, natural convection cooling is critical. Avoid mounting this switch directly adjacent to high-heat-dissipating components like power supplies or motor drives; maintain a minimum clearance of 25 mm on both sides. When calculating the fiber optic power budget, factor in a typical 5 km limit and account for connector attenuation (typically 0.75 dB per ST junction) to prevent signal degradation.

Commissioning & Wiring Tips

Always ground the IP30 metal chassis using the dedicated grounding screw located on the top panel to establish a low-impedance path for electrostatic discharge. When wiring redundant power supplies, connect V1 and V2 to separate physical power sources. This configuration allows the internal fault relay to trip and signal an external PLC alarm immediately if one of the power loops loses voltage.

Installation Guidelines

CRITICAL WARNING

De-energize all electrical power sources before attempting to wire or mount the switch. Do not plug or unplug the 6-pin terminal block while circuits are live, as this can cause electrical arcing and damage internal components.

1

Snap the switch onto a standard TS 35 DIN rail, ensuring the DIN rail clip locks firmly into place.

2

Connect a dedicated grounding wire (minimum 14 AWG) from the chassis ground screw to the main cabinet earth ground.

3

Wire the 12/24/48 V DC power lines to the removable 6-pin terminal block, then insert the block firmly into the switch socket.

4

Insert the RJ45 copper communication cables and the ST-Duplex multimode fiber optic connectors into their respective ports.

Loading product navigation…

What is the maximum fiber transmission distance for this switch?

The IE-SW-VL05M-3TX-2ST supports a typical transmission distance of up to 5 km over multimode fiber optic cables using the ST-Duplex connectors.

Does this switch support redundant power inputs?

Yes, it features dual redundant power inputs accepting 12, 24, or 48 V DC via a removable 6-pin terminal block.

What is the function of the fault relay contact on the terminal block?

The fault relay contact is a normally closed circuit that opens when one of the redundant power inputs fails, allowing an external PLC or alarm system to detect power loss.

Can this switch be mounted on a panel instead of a DIN rail?

Yes, while it comes standard with a DIN rail mounting clip, it can be panel-mounted using an optional mounting kit.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...