Product Overview

The Weidmuller 8965400000 (ACT20X-SDI-HDO-L-S) is a specialized solenoid driver module designed to control intrinsically safe (IS) valves and indicators located in hazardous areas. As a critical component of the ACT20X signal conditioner family, it serves as an isolator between safe-area control signals and Ex-zone field devices. Engineered for high-reliability process environments like chemical dosing and fuel storage, the 8965400000 converts digital control signals from a PLC or DCS into the energy-limited power required to actuate solenoid valves in ATEX/IECEx Zones 0, 1, or 2. Its integrated alarm relay and software-programmable parameters ensure that valve failures or supply losses are instantly reported, minimizing process risk and protecting expensive field assets.

Technical Configuration

The ACT20X-SDI-HDO-L-S features a single-channel, high-current output (HDO) architecture optimized for "L" (Low) power solenoid coils. It provides galvanic 3-way isolation between the input, output, and power supply, ensuring that electrical faults in the hazardous area cannot reach the control cabinet backplane.

Configuration is handled through the standardized FDT/DTM software interface, allowing engineers to set precise current limits and define the behavior of the alarm relay. The unit monitors for "No Supply Voltage" and internal "Device Error" conditions, triggering a change-over in the nominal switching relay (up to 125 VAC) to notify the supervisory system. Its 10 ms step response time ensures rapid valve actuation for time-critical safety sequences, while the 22.5 mm slim housing facilitates high-density DIN-rail mounting.

Technical Specifications

Feature Specification
Model ACT20X-SDI-HDO-L-S (8965400000)
Brand Weidmuller
Module Type Valve Control / Solenoid Driver
Output Type High Current (HDO), Low Power (L)
Step Response Time 10 ms
Voltage Supply 19.2 to 31.2 VDC
Power Consumption <= 1.9 W
Alarm Functions No supply voltage, Device error
Nominal Switching Voltage <= 125 VAC / 110 VDC
Accuracy Digital (Switching)
Protection Degree IP20
Dimensions 117.2 x 22.5 x 113.6 mm
Weight 0.170 kg

Technical FAQs

Q1: What does the "L" signify in the HDO-L-S suffix?

A1: The "L" indicates a Low-power output characteristic. This module is specifically tuned to drive intrinsically safe solenoids that require lower holding currents while maintaining sufficient voltage to ensure reliable actuation in hazardous zones.

Q2: Can I configure this module without specialized hardware?

A2: You need the Weidmuller USB interface cable and a PC with FDT/DTM software (WI-Manager). This software-based configuration allows you to verify internal diagnostics and set custom alarm conditions that are not possible with hardware DIP switches.

Q3: Is the alarm relay output "Fail-Safe"?

A3: Yes. The alarm relay is typically configured to de-energize (open contact) upon a loss of supply voltage or a device error, ensuring that the control system detects a fault even if the module loses power entirely.


Engineering & Installation Guide

  • Intrinsic Safety Compliance: Ensure that the "Entity Parameters" ($U_o, I_o, P_o$) of the 8965400000 match or exceed the requirements of your solenoid valve. The total inductance and capacitance of the field wiring must be calculated to remain within the ATEX/IECEx limits for the specific zone of installation.

  • Wiring Torque: For the screw connections, use a calibrated screwdriver to apply the manufacturer's recommended torque. Loose connections in valve control circuits are a leading cause of "Device Error" alarms due to increased contact resistance.

  • Cabinet Ventilation: When mounting several ACT20X modules side-by-side, allow for sufficient natural convection. While the module is rated for 0-95% humidity, a dry, dust-free environment will significantly extend the lifespan of the internal isolation transformers and switching relays.

Engineering Advantages

The 8965400000 is distinguished by its 3-way isolation and 10 ms response time, making it an ideal choice for Emergency Shutdown (ESD) applications. Its software-centric configuration allows for "digital fingerprinting" of the device setup, making it easy for maintenance teams to replicate settings across multiple units during plant expansions. Furthermore, the inclusion of a high-voltage switching relay (125 VAC) allows this module to directly interface with legacy 110V alarm systems, eliminating the need for interposing relays and simplifying the overall control cabinet bill of materials.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Germany
Power source
DC Power

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...