Weidmuller

Weidmuller 8965340000 ACT20X-HDI-SDO-RNO-S Isolating Switch Amplifier

SKU 8965340000

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Weidmuller

  • Product No.: 8965340000

  • Country of origin:Germany

  • Product Type: Isolating Switch Amplifiers

  • Payment: T/T, Western Union

  • Weight: 177g

  • Dimensions: 119.2 mm x 22.5 mm x 113.6 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Processing digital signals from hazardous zones requires robust galvanic isolation and signal conditioning. The Weidmuller 8965340000 functions as an intrinsically safe isolating switch amplifier designed to interface NAMUR sensors or mechanical contacts located in Ex zones 0, 1, and 2 with safe-area controllers. This dual-channel module provides reliable signal transmission while ensuring complete electrical isolation between the input, output, and power supply circuits. Configurable via FDT/DTM software, the device allows for precise parameterization of line monitoring (wire break and short-circuit detection) and output behavior.

Features

  • Dual-channel signal transmission for space-saving DIN rail installation.
  • Intrinsically safe input circuits compatible with NAMUR sensors (EN 60947-5-6) and dry contacts.
  • Relay outputs (normally open) for switching AC/DC loads.
  • Comprehensive line fault detection (LFD) for identifying short circuits or cable breaks.
  • Galvanic 3-way isolation between input, output, and power supply.
  • FDT/DTM software configuration for flexible parameter adjustments.

Applications

  • Chemical and petrochemical processing plants
  • Oil and gas extraction and refining facilities
  • Wastewater treatment and hazardous material storage
  • Power generation and distribution systems

Technical Specifications

Manufacturer Weidmuller
Part Number/Model 8965340000 (ACT20X-HDI-SDO-RNO-S)
Product Type Isolating Switch Amplifier
Number of Channels 2
Supply Voltage 19.2 to 31.2 V DC
Power Consumption <= 1.3 W
Input Type NAMUR sensor (EN 60947-5-6) or switch contact
Input Supply 8 V DC / 8 mA
Output Type Relay (1 NO contact per channel)
Nominal Switching Voltage 250 V AC / 30 V DC
Configuration FDT/DTM software
Connection Type Screw connection
Protection Degree IP20
Operating Temperature -20 to +60 degC
Storage Temperature -20 to +85 degC
Relative Humidity 0 to 95% (non-condensing)
Weight 0.177 kg
Dimensions (H x W x D) 119.2 mm x 22.5 mm x 113.6 mm

Connections and Interfaces

Terminal Pin Function
11, 12 Channel 1 Input (NAMUR / Switch)
21, 22 Channel 2 Input (NAMUR / Switch)
51, 52 Channel 1 Relay Output (NO)
61, 62 Channel 2 Relay Output (NO)
91, 92 Power Supply (19.2 - 31.2 V DC)

Installation Guidelines

  • Mounting: Snap-on mounting onto standard TS 35 DIN rails.
  • Wiring: Use screw terminals with appropriate wire cross-sections. Ensure intrinsic safety separation rules are followed (minimum 50 mm distance between Ex-i and non-Ex-i wiring).
  • Grounding: Ensure the DIN rail is properly grounded to maintain signal integrity and safety compliance.
  • Ventilation: Maintain adequate clearance around the module to prevent heat buildup.

Compliance and Certifications

  • ATEX
  • IECEx
  • CE
  • cULus

FAQ

What is the primary function of the Weidmuller 8965340000?

The Weidmuller 8965340000 (ACT20X-HDI-SDO-RNO-S) is a 2-channel isolating switch amplifier designed to safely transmit digital signals from NAMUR sensors or mechanical switches in hazardous Ex zones to safe-area control systems.

How is the ACT20X-HDI-SDO-RNO-S configured?

This isolating switch amplifier is configured using standard FDT/DTM software, allowing users to customize line fault detection, output behavior, and signal direction.

What type of outputs does this module provide?

The module features relay outputs with one normally open (NO) contact per channel, rated for up to 250 V AC or 30 V DC.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.