1 of 1

Weidmuller 8965450000 ACT20X-SAI-HAO-S Current Output Isolator

Weidmuller 8965450000 ACT20X-SAI-HAO-S Current Output Isolator

Only 10 item(s) left in stock
  • Manufacturer: Weidmuller

  • Product No.: 8965450000

  • Country of origin:Germany

  • Product Type: Current Output Isolators

  • Payment: T/T, Western Union

  • Weight: 189g

  • Dimensions: 117.2 mm x 22.5 mm x 113.6 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Weidmuller 8965450000 ACT20X-SAI-HAO-S Current Output Isolator

Description

Designed for hazardous area applications, the Weidmuller 8965450000 (ACT20X-SAI-HAO-S) provides reliable galvanic isolation and signal conditioning for analog current outputs. This high-performance current output isolator safely transmits control signals from safe-area controllers to intrinsically safe (Ex i) actuators, control valves, or I/P converters located in hazardous environments. Featuring an integrated alarm relay, the module monitors critical faults such as line interruptions, signal limit violations, and power supply failures, ensuring maximum process safety and system availability.

The device is fully configurable via standard FDT/DTM software, allowing engineers to customize alarm thresholds and operational parameters to match specific process requirements. Its compact 22.5 mm housing design optimizes cabinet space, making it an ideal choice for high-density control panels in demanding industrial environments.

Features

  • Galvanic isolation between input, output, and power supply circuits.
  • Intrinsically safe (Ex i) output design for hazardous area field devices.
  • Integrated alarm relay for real-time fault signaling and diagnostics.
  • FDT/DTM software-based configuration for precise parameterization.
  • Fast step response time of 5 ms or less for dynamic control loops.
  • Compact DIN-rail mountable housing with screw connection technology.

Applications

  • Chemical and petrochemical processing plants.
  • Oil and gas extraction, refining, and distribution.
  • Water and wastewater treatment facilities.
  • Power generation and utility control systems.
  • Intrinsic safety isolation for control valves, positioners, and I/P converters.

Technical Specifications

Manufacturer Weidmuller
Part Number / Model 8965450000 (ACT20X-SAI-HAO-S)
Product Type Current Output Isolator
Voltage Supply 19.2...31.2 V DC
Power Consumption <= 1.0 W
Accuracy < 0.1% of span
Temperature Coefficient < 0.01% of span / degC (TU)
Step Response Time <= 5 ms
Nominal Switching Voltage (Alarm) <= 125 V AC / 110 V DC
Continuous Current (Alarm) <= 0.5 A AC / 0.3 A DC
Alarm Functions Signal limit exceeded, Line interruption at the input, No supply voltage, Device error
Configuration FDT/DTM software
Type of Connection Screw connection
Protection Degree IP20
Operating Humidity 0...95% (no condensation)
Weight 0.189 kg
Dimensions (H x W x D) 117.2 mm x 22.5 mm x 113.6 mm

Installation Guidelines

  • Mounting: Install the device vertically on a standard TS 35 DIN rail.
  • Ventilation: Ensure adequate clearance around the module to facilitate natural convection cooling, especially when mounting multiple units side-by-side.
  • Wiring: Use appropriate wire cross-sections for the screw terminals. Keep intrinsically safe (Ex i) field wiring physically separated from non-intrinsically safe power and signal wiring in compliance with local electrical codes.
  • Grounding: Ensure the DIN rail is properly grounded to a low-impedance earth ground to maintain signal integrity and safety shielding.

What is the primary function of the Weidmuller 8965450000?

The Weidmuller 8965450000 (ACT20X-SAI-HAO-S) is a current output isolator designed to safely isolate and transmit analog current signals from safe control areas to intrinsically safe (Ex i) actuators or devices in hazardous environments.

How is the ACT20X-SAI-HAO-S configured?

This module is configured using standard FDT/DTM software, allowing precise parameterization of signal limits, alarm thresholds, and device diagnostics.

What alarm functions are integrated into this isolator?

The device features integrated alarm relays that trigger when a signal limit is exceeded, an input line interruption occurs, supply voltage is lost, or an internal device error is detected.

What is the step response time of this module?

The ACT20X-SAI-HAO-S features a fast step response time of 5 milliseconds or less, making it suitable for dynamic industrial control loops.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...