The Yokogawa PW441-11 is a high-reliability Power Supply Module designed for integration within CENTUM VP distributed control systems (DCS). This unit functions as a primary power regulation module, converting incoming alternating current into stable, filtered direct current required to drive critical field control components, processing modules, and communication interfaces. Built to support high-availability process automation, the PW441-11 can be deployed in a dual-redundant configuration within compatible station chassis, ensuring continuous system operation and zero-downtime protection against primary power line faults or individual module failures.
Features
Dual-redundant configuration compatibility to prevent system downtime during electrical faults.
Direct integration into CENTUM VP distributed control station hardware.
Advanced filtering functionality to suppress high-frequency line noise and protect sensitive logic circuits.
Built-in safeguards including overvoltage and short-circuit protection.
Compact form factor optimized for seamless installation in space-constrained node units.
Applications
Distributed Control Systems (DCS) power networks in oil and gas production.
Power supply regulation for chemical, refining, and petrochemical control loops.
Mission-critical thermal power plant instrumentation and utility systems.
Technical Specifications
Attribute
Specification
Manufacturer
Yokogawa Electric Corporation
Model
PW441-11
Module Type
Power Supply Module
System Compatibility
CENTUM VP DCS
Input Voltage Range
100-120 V AC (85-264 V AC continuous tolerance)
Input Frequency
50/60 Hz
Redundancy Support
Yes (Dual Module Configuration)
Protection Features
Overvoltage, undervoltage, and short-circuit protection
Noise Filtering
High-frequency suppression
Country of Origin
Japan
Dimensions (Approx.)
4.8 x 14.6 x 13 cm
Weight (Approx.)
0.6 kg
Installation Guidelines
Redundant Configuration Setup: To achieve full system redundancy, mount two separate modules side-by-side inside the designated power terminal slots of the control unit backplane.
Wiring Configurations: Connect the main utility line securely using verified M4 screw terminals to guarantee robust vibration resistance.
Cooling and Ventilation: Maintain clean, unobstructed air passage around the chassis rack to allow proper heat dissipation from the active power circuitry.
Polarity and Phase Verification: Verify incoming AC power lines conform to nameplate phase requirements before energizing the module.
FAQ
Does the power supply support a redundant operation layout?
Yes, the module supports a dual-redundant configuration where two modules run together to ensure continuous system power delivery if one unit fails.
What is the specific nominal input voltage rating for this device?
The module operates on a nominal input rating of 100-120 V AC at a frequency of 50/60 Hz.
What internal safety safeguards are engineered into the power supply?
The module features built-in protective circuitry for overvoltage, undervoltage, and short-circuit fault conditions.
A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...
Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...
Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...
Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.
Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.
A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...
Choosing a selection results in a full page refresh.