1 de 3

05701-A-0302 | Honeywell | Single Channel Control Card Catalytic

05701-A-0302 | Honeywell | Single Channel Control Card Catalytic

Only 3 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 05701-A-0302

  • Country of origin:Reino Unido

  • Product Type: Gas Detection Control Cards

  • Payment: T/T, Western Union

  • Weight: 165g

  • Dimensions: 17cm x 2,5cm x 11,2cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantidade
Ver informações completas

Description

The Honeywell 05701-A-0302 is a microprocessor-based gas monitoring interface card engineered specifically to control and process signals from catalytic bridge sensors within the System 57 framework. This single-channel control card interfaces directly with field-mounted combustible gas sensors, providing the essential excitation voltage and bridge conditioning circuitry needed to evaluate hazardous gas concentrations. Operable as an autonomous safety element inside industrial racks, the device continuously performs comprehensive self-testing loops to monitor internal operation, configuration integrity, and active sensor loop continuity.

The module incorporates a specialized four-part liquid crystal display on its front face to provide a local indication of flammable gas levels via an analogue bar segment representation alongside explicit numeric and diagnostic text strings. The processed sensor signals are evaluated against adjustable threshold points to trigger alarm states across the common sub-rack backplane, interfacing seamlessly with centralized alarm loops, industrial automation systems, and discrete safety shutdown mechanisms.

Features

  • Features an integrated four-part liquid crystal display comprising a 25-segment analogue bar indicator, a 4-character digital concentration window, a 4-character message block, and operational status icons.
  • Equipped with dedicated front-panel indicators including LEDs for A1, A2, A3 gas alarms, alongside system Fault and channel Inhibit indicators.
  • Provides a front-facing Alarm Reset/Card Select push-button allowing operations personnel to reset latched alarm flags or toggle local programming configurations.
  • Supports high-precision safety threshold engineering with Alarm Setting Point Resolution fully adjustable in discrete 1% fsd steps.
  • Features low-drift signal conversion circuitry providing an Electronic Drift stability threshold restricted to less than plus or minus 2% over a 6-month continuous runtime.

Applications

  • Fixed combustible gas monitoring networks in onshore petrochemical refineries and offshore production platforms.
  • Specialized gas detection panels in heavy machinery spaces, marine engine rooms, and industrial boiler utilities.
  • Marshaling cabinets requiring individual loop separation for catalytic bead sensors protecting critical manufacturing plant perimeters.

Technical Specifications

Parameter Specifications
Manufacturer Honeywell
Model Number 05701-A-0302
Product Type Single Channel Control Card Catalytic
Product Series System 57 / 5701 Series Control System
DC Supply Range 18V to 32V dc
Power Consumption (Catalytic) 3.75W (typical, including Catalytic Sensor load)
Power Consumption (4 - 20mA compatibility) 3.25W (typical)
Electronic Drift Rate Less than ±2% / 6 months
Alarm Configuration Resolution In 1% fsd steps
Country of Origin United Kingdom
Dimensions (L x W x H) 17cm x 2.5cm x 11.2cm
Weight 0.165 Kg

Connections/Interfaces

Connector / Interface Function
SK1 15-way D-type female socket for physical coupling to field terminal cards or relay expansion assemblies
SK2 32-way backplane socket routing power lines, common relay contacts, and serial communications
J1 / J2 14-way internal headers carrying the plug-in sensor drive module tailored for catalytic bridges
J3 / J4 8-way onboard expansion headers accommodating an optional isolated analogue output expansion block
FS1 Internal low-voltage overcurrent protection fuse

Installation Guidelines

  • Sub-Rack Installation: Slide the module into its designated slot inside the System 57 19-inch sub-rack frame, verifying that both the upper and lower mechanical guide rails are fully engaged before pressing the card home.
  • Shielding and Interface Paths: Route all field sensor connections through the matching interface block or relay termination card using multi-conductor shielded cables up to 2.5mm2 cross-sectional area.
  • Grounding for Catalytic Bridges: Terminate the external cable shielding sheath directly to the system earth grounding stud on the termination block assembly to isolate precision bridge signals from localized EMI/RFI noise.
  • Single-Point Earth Termination: If the field-mounted sensor enclosure is connected to structural metalwork, ensure the shielding path is tied only at the controller rack frame to avoid creating hazardous ground loop pathways.
  • Thermal Management: Maintain an unobstructed airflow path across the top and bottom ventilation openings of the sub-rack housing to preserve structural component life under full catalytic drive loads.

FAQ

  • What is the difference between the 05701-A-0301 and this 05701-A-0302 model?

    The 05701-A-0302 comes factory-configured with an internal sensor drive module optimized to run and excite passive 3-wire catalytic bead sensors directly, whereas the 05701-A-0301 is tailored for active 4-20mA current loop transmitters.

  • How are the local alarm thresholds calibrated or altered on this device?

    The trip values and full-scale calibration parameters are managed through an onboard microprocessor and written into an internal non-volatile memory block, which requires an external Engineering Card or compatible diagnostic software configuration kit to adjust.

  • Is it necessary to power down the entire control rack to replace a single card?

    No, individual channels function as completely isolated control loops, permitting maintenance personnel to insert or remove a single module while neighboring slots remain fully operational.

  • How should unused channels inside a multi-slot rack assembly be configured?

    Unused slots do not require empty cards; however, if a card is installed but not tied to a live sensor loop, the specific channel must be set to the permanently inhibited state via software or hardware bridges to avoid generating constant field fault states.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

05701-A-0302 | Honeywell | Single Channel Control Card Catalytic

正在加载 PDF,请稍候…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Preto Verde
Country of origin
Reino Unido
Power source
Energia CC

Recently Viewed Products

Technical knowledge

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...

Configuração de Controle de Movimento de Eixo Único com Drives Servo CMZ

Este tutorial explora a comissionamento de um sistema de movimento servo de eixo único usando um drive CMZ SBD, abrangendo a configuração de hardware, escala do eixo, configuração de homing e...