1 de 6

ABB DI810 3BSE008508R1 S800 I/O 16-Channel Digital Input Module

ABB DI810 3BSE008508R1 S800 I/O 16-Channel Digital Input Module

Only 10 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: 3BSE008508R1

  • Country of origin:Suécia

  • Product Type: 16-Channel Digital Input Module

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 45 mm x 119 mm x 102 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantidade
Ver informações completas

Product Overview

The DI810 (3BSE008508R1) is a high-density digital input module designed for the ABB S800 I/O family. This versatile module features 16 channels specifically rated for 24 VDC signals, making it a cornerstone for industrial automation within the 800xA, Advant OCS, and Compact Product Suite environments. The DI810 is engineered for maximum reliability, featuring galvanic isolation between two groups of 8 channels to prevent ground loops and protect the system bus from field-side electrical interference. Its compact design and "hot-swap" capability ensure that process interruptions are minimized, providing a scalable and robust interface for discrete sensors, switches, and auxiliary contacts in demanding applications such as power generation, chemical processing, and marine engineering.

Technical Configuration

The DI810 architecture is optimized for seamless integration and field-side flexibility:

  • Channel Density: Provides 16 digital input channels, categorized into two isolated groups of 8 channels each, allowing for different power source references within a single module.

  • MTU Compatibility: Designed to be used with a wide range of Module Termination Units (MTU), including the TU810, TU812, TU814, TU818, TU830, TU833, TU838, and TU850, providing various wiring options (crimp, screw, or spring).

  • System Versatility: Fully compatible with ABB’s flagship control systems, including System 800xA (versions 4.0 through 6.0), Advant Fieldbus 100, and the Compact Product Suite.

  • Input Logic: Standard 24 VDC positive logic, optimized for industrial standard sensors and mechanical contacts.

  • Modular Design: Features a plug-and-play interface that connects directly to the S800 I/O backplane/MTU, allowing for rapid deployment and easy maintenance.

Technical Specifications

Feature Details
Model DI810
Product ID 3BSE008508R1
Brand ABB
System S800 I/O
Number of Channels 16 (Isolated in 2 groups of 8)
Rated Voltage 24 V DC
Product Net Weight 0.2 kg
Dimensions (WxHxD) 45 mm x 119 mm x 102 mm
Power Dissipation Low-power design for high-density packing
Isolation Group-to-group and group-to-bus isolation
Operating Temp 0 to 55 deg C (standard industrial range)

Technical FAQs

Which Module Termination Unit (MTU) should I select for the DI810?

The selection depends on your wiring preference. For standard screw terminals, the TU810 or TU830 are common choices. If your application requires high-density spring terminals to resist vibration, the TU812 or TU814 is recommended.

Can the two groups of 8 channels be powered by different 24V sources?

Yes. Because the two groups are isolated from each other, you can use independent power supplies for each group of 8 channels, which is ideal for systems requiring physical separation of safety or interlocking circuits.

Does the DI810 support "Hot-Swap" functionality?

Yes. When used within an S800 I/O station, the DI810 module can be removed and replaced while the system is powered (under certain configuration conditions), significantly reducing downtime during maintenance.


Engineering & Installation Guide

  • MTU Installation: Ensure the Module Termination Unit (MTU) is securely fastened to the DIN rail before plugging in the DI810 module. The module should snap into place with a firm click to ensure the internal bus connectors are fully engaged.

  • Field Wiring: For 24 VDC inputs, ensure that the cable runs are appropriately shielded if they pass near high-voltage motor cables. The isolation in the DI810 provides protection, but good EMC practices prevent nuisance signal flickering.

  • Group Isolation: Remember that channels 1-8 share a common return and channels 9-16 share a separate common return. Do not bridge these returns if you wish to maintain the galvanic isolation between the two groups.

  • Environmental Sealing: In environments with high humidity or corrosive gases, ensure the I/O cabinet is appropriately rated. The DI810 is a compact IP20-rated module and relies on the enclosure for primary environmental protection.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB DI810 3BSE008508R1 S800 I/O 16-Channel Digital Input Module

正在加载 PDF,请稍候…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Branco
Country of origin
Suécia
Power source
Energia CC

Recently Viewed Products

Technical knowledge

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...

Configuração de Controle de Movimento de Eixo Único com Drives Servo CMZ

Este tutorial explora a comissionamento de um sistema de movimento servo de eixo único usando um drive CMZ SBD, abrangendo a configuração de hardware, escala do eixo, configuração de homing e...