1 de 6

ABB FPBA-01 ACS Series PROFIBUS DP Adapter Module

ABB FPBA-01 ACS Series PROFIBUS DP Adapter Module

Apenas 4 item(ns) restante(s) em estoque
  • Fabricante: ABB

  • Nº do Produto: FPBA-01

  • País de origem:Suécia

  • Tipo de Produto: PROFIBUS Adapter Modules

  • Código de barras: 85044095

  • Pagamento: T/T, Western Union

  • Peso: 100g

  • Dimensões: 7.60 cm x 7.60 cm x 2.50 cm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver informações completas

Description

Establishing high-performance cyclic and acyclic data exchange between industrial control networks and variable speed drives, the ABB FPBA-01 PROFIBUS DP communication adapter module provides seamless integration into distributed control architectures. This interface module slides directly into the drive slot, enabling standard PROFIdrive or ABB Drives communication profiles to command, monitor, and configure parameters on compatible frequency converters. Operating with 16-bit word lengths, it ensures reliable signal transmission under demanding electromagnetic conditions typical of industrial plant floors.

Key Technical Features

  • Multi-Protocol Support: Full compliance with both PROFIBUS DP-V0 and DP-V1 standards, allowing cyclic process data exchange and acyclic parameter configuration.
  • Adaptive Baud Rate Detection: Automatically locks onto network speeds ranging from 9.6 kbit/s up to 12 Mbit/s, eliminating manual transmission rate configurations.
  • Versatile Control Profiles: Native support for the standard PROFIdrive profile as well as the proprietary ABB Drives profile for system flexibility.
  • Direct Slot Integration: Compact physical form factor designed to mount inside the drive housing, receiving internal control power directly from the host drive.

Industrial Applications

  • Continuous Process Environments: Connecting variable speed pump and fan drives in water/wastewater facilities to centralized PLCs.
  • Automated Material Handling: Synchronization of conveyor speed controllers in packaging and logistics distribution lines.
  • Machinery Manufacturing: High-density multi-axis machinery configurations using ACS355 drive blocks controlled via a centralized Siemens master controller.

Technical Specifications Table

Parameter Specification Value / Limit
Manufacturer ABB
Model Identifier FPBA-01
Internal Part Code 68469325
Host Drive Compatibility ACS355, ACS350, ACS850, ACQ810, ACS880, ACS580 Series
Communication Protocol PROFIBUS DP-V0 and DP-V1
Baud Rate Range 9.6 kbit/s to 12 Mbit/s (Auto-detecting)
Connection Interface 9-pin D-sub (female) connector
Current Consumption Max 80 mA at 24 VDC (supplied from host drive)
Commodity Code 85044095
Dimensions 7.60 cm x 7.60 cm x 2.50 cm
Net Weight 0.10 kg

Connections and Pin Assignments

The fieldbus physical layer utilizes a 9-pin Sub-D female block configured as follows:

Pin Number Signal Name Description
1 SHLD Chassis and Cable Shield Connection
3 RxD/TxD-P (B-Line) Positive Data Transmission (Red Wire)
5 DGND Data Ground (Reference potential)
6 VP +5 VDC Power supply for termination resistors
8 RxD/TxD-N (A-Line) Negative Data Transmission (Green Wire)

Empirical Engineering Insights

Alternative Models & Compatibility

The FPBA-01 acts as a universal communication adapter for multiple series of ABB drives. However, some legacy ACS350 drives require a dedicated firmware revision level to map DP-V1 acyclic blocks correctly. Check parameter group 51 (Fieldbus Parameter Group) after hardware discovery to confirm that the driver version is recognized by the VFD main board.

Application Pitfalls & Engineering Notes

A common cause of bus faults during system startups is the lack of proper network termination on physical line ends. If the FPBA-01 sits at the physical end of the PROFIBUS segment, a SUB-D connector containing integrated termination switches must be used, and the switch must be toggled to 'ON'. Ensure that this termination connector receives power from Pin 6 (+5V) and Pin 5 (DGND) on the FPBA-01 module.

Commissioning & Wiring Tips

When compiling the master PLC database, ensure the correct GSD configuration file is loaded (typically ABB_090F.GSD). After altering parameter values in Group 51, a parameter refresh is mandatory. Trigger Parameter 51.27 (FBA PAR REFRESH) or perform a complete drive power cycle to commit the node address changes to active memory.

Installation Guidelines

CRITICAL SAFETY WARNING

Ensure the host drive is fully de-energized. Wait a minimum of 5 minutes after switching off the main incoming power supply to allow the DC bus capacitors to discharge completely. Use a calibrated multimeter to confirm zero voltage at the drive terminals before inserting or removing the communication card.

1
Align the male multi-pin header on the rear of the FPBA-01 adapter with the corresponding interface option slot on the host drive control panel area.
2
Carefully press the module in place until the retaining plastic tabs engage with the drive frame to secure physical placement.
3
Tighten the integrated mounting/grounding screw to establish reliable chassis grounding and prevent vibration-induced disconnections.
4
Insert the standard 9-pin Sub-D PROFIBUS connector and secure it using the thumb screws. Route the fieldbus cable far from high-power phase wiring.
Loading product navigation…

Can the FPBA-01 module be hot-swapped while the host drive is powered?

No. Removing or inserting the module while control power is applied to the drive can permanently damage the internal interfaces of both the drive and the adapter module.

How is the PROFIBUS node address assigned for this module?

The node address is set using Group 51 parameters (specifically parameter 51.02) via the drive's control panel or drive commissioning software. Address configurations from 1 to 125 are supported.

Does the FPBA-01 require an external 24V power supply to work?

No. The module is directly powered through the drive’s internal slot connection, drawing a maximum of 80 mA of internal power.

What is the differences between DP-V0 and DP-V1 operation on the FPBA-01?

DP-V0 supports cyclic data exchange, such as control words, status words, and speed references. DP-V1 compatibility adds acyclic read/write commands, enabling advanced parameter modification directly from the PLC.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Suécia

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...