1 de 6

ABB GHR4140000VO Procontic Multi-input OR Gate Module

ABB GHR4140000VO Procontic Multi-input OR Gate Module

Apenas 2 item(ns) restante(s) em estoque
  • Fabricante: ABB

  • Nº do Produto: GHR4140000VO

  • País de origem:Suécia

  • Tipo de Produto: PLC Logic Modules

  • Código de barras: 85389091

  • Pagamento: T/T, Western Union

  • Peso: 100g

  • Dimensões: 13.5 x 8.0 x 2.2 cm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver informações completas

Description

Executing hardware-level logic operations within the legacy Procontic control architecture, the ABB GHR4140000VO provides robust signal gating without software processing overhead. This passive industrial logic module is engineered with three independent OR gate circuits designed to consolidate control signals, interlocks, and permissive loops in high-reliability systems. Because the signal paths are non-amplified, the module functions with zero current draw from the system power supply, making it an exceptionally stable and fail-safe component for discrete industrial logic control panels.

Features

  • Independent Gating Circuits: Features three isolated OR functions, providing two 2-input gates and one 3-input gate on a single physical module.
  • Passive Signal Path: Operates entirely on input signal power with zero internal power supply burden.
  • Zero Propagation Delay: Real-time hardware switching logic with no digital processing or software scanning latency.
  • High-Density Integration: Housed in a compact single-width format for efficient mounting within standard ABB Procontic racks.
  • Standardized Visual Coding: Distinct black visual identifier for rapid card-type classification during maintenance cycles.

Applications

  • Legacy ABB Procontic PLC system retrofits and hardware logic interlocking.
  • Multi-station emergency shutdown (ESD) systems and permissive start-up loops.
  • Hardwired signal concentration and voting logic arrays.

Ordering Information

Order Item Description Order Code / Part Number
GHR4140000VO Module GH R414 0000 V0
Circuit Symbol Transparency GH R700 1901 R3
Application Reference Documentation D GEF 31014 D

Technical Specifications

Parameter / Specification Value / Rating
Manufacturer ABB
Model Number GHR4140000VO
Series Procontic
Gate Configuration 2 x 2-Input OR Gates, 1 x 3-Input OR Gate
Logic Formula Q = A OR B OR C
Nominal Circuit Voltage 24 VDC
Max. Series Cascade 4 Modules (at 24 VDC nominal)
Signal Amplification None (Passive module)
Module Power Consumption 0 mA (Zero burden on control supply voltage)
Propagation Delay Undelayed (instantaneous hardware response)
Identifying Module Color Black
Mechanical Form Factor Single width
Shipping Weight (Calculated) 0.11 kg
Package Dimensions (Calculated) 13.5 x 8.0 x 2.2 cm

Alternative Models & Compatibility

The GHR4140000VO logic module is fully backwards-compatible with standard ABB Procontic mounting frames and connector backplanes. If sourcing drop-in replacements, ensure that the mechanical coding pins on the chassis match the single-width configuration of this black-coded component. When replacing legacy active logic units with this passive module, confirm that upstream transmitters have appropriate output driving specifications.

Application Pitfalls & Engineering Notes

Because this logic module is completely passive and contains no internal signal amplification, cascading more than 4 gates in a single serial chain with 24 VDC can lead to excessive signal attenuation. Ensure downstream receivers can accurately detect the logic-high threshold despite cumulative series voltage drops. Additionally, note that input loading calculations must account for the sum total of downstream destination loads linked to the output channel.

Commissioning & Wiring Tips

Always verify signal source impedances during initial setup. High-impedance sensors or low-power solid-state outputs may struggle to drive multiple parallel inputs on passive OR gates. We recommend using shielded twisted-pair cabling for remote logic routing to avoid high-frequency noise injection on passive lines, which could lead to false logic-high triggers at high-speed receiving terminals.

Installation Guidelines

CRITICAL WARNING

De-energize all connected input and output control loops before inserting or extracting the logic module from the Procontic backplane. Hot-plugging passive modules can cause transient voltage spikes, leading to false-triggering of adjacent hardware interlocking circuitry.

1 Verify that the backplane slot is clean, free of debris, and matches the single-width spacing profile of the module.
2 Align the edge-card connectors carefully with the backplane receptacle and slide the unit steadily until the card is fully seated.
3 Secure any retention screws or mechanical latches to protect against severe cabinet vibration.
4 Power on individual input logic feeds one by one to verify output logic switching behavior locally at the terminals.
Loading product navigation…

What is the maximum signal cascade depth for the GHR4140000VO?

Up to four OR gate modules may be connected directly in series when operating on a standard 24 VDC circuit. Cascading beyond this limit is not recommended because the passive, non-amplifying circuitry causes cumulative voltage drops.

Does this module require an external connection to a system power supply?

No. The module is passive and operates strictly using the power supplied by the input signals. It does not place any burden on the system's central power supply rail.

What logic configuration is available on the module?

The module contains three separate, independent OR gate circuits. Two are configured as 2-input gates, and one is configured as a 3-input gate.

What is the switching delay of the logic gates?

The gates are undelayed. Because the module utilizes passive hardware circuits rather than digital microprocessor logic, signal propagation is instantaneous.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Suécia

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...