1 de 3

ABB S201-B6 2CDS251001R0065 S200 Miniature Circuit Breaker

ABB S201-B6 2CDS251001R0065 S200 Miniature Circuit Breaker

Apenas 55 item(ns) restante(s) em estoque
  • Fabricante: ABB

  • Nº do Produto: S201-B6 2CDS251001R0065

  • País de origem:Suécia

  • Tipo de Produto: Miniature Circuit Breakers

  • Pagamento: T/T, Western Union

  • Peso: 112g

  • Dimensões: 88 mm x 17.5 mm x 69 mm (H x W x D)

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

The S201-B6 miniature circuit breaker with Product ID 2CDS251001R0065 is a single-pole, current-limiting safety device engineered to provide comprehensive overcurrent mitigation and short-circuit fault protection. As a core component of the System pro M compact S200 product range, this device features two distinct internal tripping mechanisms: a delayed thermal tripping configuration optimized for overload security and an electromechanical magnetic tripping assembly designed for instantaneous short-circuit protection. This circuit breaker is rated for a 6 A operational current and complies fully with major international standards including IEC/EN 60898-1, IEC/EN 60947-2, and UL1077, enabling seamless system compatibility across diverse residential, commercial, and heavy industrial automation environments.

Features

  • Incorporates a 1P single-pole configuration designed for space-saving terminal tracking and efficient distribution layout.
  • Utilizes a B-characteristic tripping curve calibrated for specific line and low-surge inductive application parameters.
  • Features an integrated contact position indicator with a clear visual window displaying Red for ON and Green for OFF states.
  • Outfitted with a failsafe bidirectional cylinder-lift screw terminal setup to optimize wiring stability and prevent installation errors.
  • Engineered for high modular versatility with full compatibility for bottom-fitting auxiliary contact installations and accessories.

Applications

  • Low-voltage electrical distribution boards and branch circuit panel assemblies.
  • Industrial control panels, manufacturing automation loops, and specialized machinery control networks.
  • Commercial building facility management grids and standard residential infrastructure protection loops.

Ordering Information

Parameter Value
Extended Product Type S201-B6 
Product ID 2CDS251001R0065 
EAN 4016779464901 

Technical Specifications

Parameter Specification
Manufacturer ABB 
Extended Product Type S201-B6 
Product ID 2CDS251001R0065 
Number of Poles 1P 
Number of Protected Poles
Tripping Characteristic
Rated Current (In) 6 A 
Input Voltage Type AC/DC 

 

Rated Operational Voltage

acc. to IEC 60898-1 230 V AC 

 

Rated Insulation Voltage (Ui)

acc. to IEC/EN 60664-1 440 V 
Rated Impulse Withstand Voltage (Uimp) 4 kV (5 kV at 2000 m / 6.2 kV at Sea Level) 
Dielectric Test Voltage 50/60 Hz - 1 min: 2 kV 
Rated Short-Circuit Capacity (Icn) (AC) 6 kA / (DC) 6 kA / (230/400 V AC) 6 kA 
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (133 V AC) 20 kA / (230 V AC) 10 kA / (24 V DC) 20 kA / (60 V DC) 10 kA / (230 V) 10 kA / (400 V) 10 kA 
Rated Service Short-Circuit Breaking Capacity (Ics) (133 V AC) 15 kA / (230 V AC) 7.5 kA 
Rated Conditional Short-Circuit Current (Inc) (230 V) 10 kA / (400 V) 10 kA 
Rated Frequency (f) 50/60 Hz 
Power Loss 2 W (2 W per Pole at Rated Operating Conditions) 
Housing Material Insulation Group II, RAL 7035 
Actuator Material Insulation Group II, Black, Sealable 
Actuator Type Toggle 
Contact Position Indication Red ON / Green OFF 
Energy Limiting Class
Electrical Endurance 20000 AC cycle 
Mechanical Endurance 20000 cycle 
Terminal Type Screw Terminals 
Screw Terminal Type Failsafe Bidirectional Cylinder-lift Terminal 
Connecting Capacity Busbar 10/10 mm² / Flexible with Ferrule 0.75 ... 25 mm² / Flexible 0.75 ... 25 mm² / Rigid 0.75 ... 35 mm² / Stranded 0.75 ... 35 mm² 
Tightening Torque 2.8 N-m 
Recommended Screw Driver Pozidriv 2 
Wire Stripping Length 12.5 mm 
Ambient Air Temperature Operation -25 ... +55 Celsius / Storage -40 ... +70 Celsius 
Degree of Protection IP20 (Enclosure with Cover IP40) 
Pollution Degree
Maximum Operating Voltage UL/CSA 60 V DC / 480Y/277 V AC 
Interrupting Rating acc. to UL1077 (277 V AC) 6 kA / (60 V DC) 10 kA / (120 V) 10 kA 
Connecting Capacity UL/CSA Busbar 18-8 AWG / Conductor 18-4 AWG 
Tightening Torque UL/CSA 18 in-lb 
Product Net Width 17.5 mm 
Product Net Height 88 mm 
Product Net Depth / Length 69 mm 
Product Net Weight 0.112 kg 

Installation Guidelines

  • DIN Rail Installation: Secure the unit firmly onto standard symmetrical tracking choices, including TH35-15 (35 x 15 mm mounting rail) or TH35-7.5 (35 x 7.5 mm mounting rail) according to the IEC 60715 standard.
  • Mounting Position: The underlying physical design permits installation and execution at any functional mechanical angle orientation.
  • Power Supply Connection: The architecture allows for arbitrary power supply connection placements based on structural needs.
  • Terminal Anchoring: Securely clamp the conductors inside the failsafe bi-directional cylinder-lift terminals with a Pozidriv 2 screwdriver to a certified torque of 2.8 N-m (18 in-lb for UL/CSA configurations).

Compliance and Certifications

  • Declaration of Conformity - CE: 2CDK403001D0607 
  • Declaration of Conformity - UKCA: 9AKK108467A5053 
  • Certification Agencies: EN, IEC, UL 
  • Standards: IEC/EN 60898-1, IEC/EN 60947-2, UL 1077
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB S201-B6 2CDS251001R0065 S200 Miniature Circuit Breaker

What standard visual cues does the device provide for terminal position updates?

The device features a mechanical contact position indication window that clearly shows Red for an ON status and Green for an OFF status.

What is the calibrated physical tightening torque for terminal connections?

The integrated screw terminals require an engineering tightening torque value of 2.8 N-m for standard industrial tasks or 18 in-lb for UL/CSA arrangements.

What internal mechanical protections are integrated into the device?

The device contains dual safety solutions: a delayed thermal tripping mechanism for overload mitigation and an electromechanical magnetic tripping system for short circuits.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendemos mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Aceitamos devoluções de produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso site oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Suécia

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação, dentro da automação industrial. Ele mostra...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas em FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem às...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel fundamental na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...