1 de 3

ABB SPDSI22 Symphony Plus Digital Input Module

ABB SPDSI22 Symphony Plus Digital Input Module

Apenas 6 item(ns) restante(s) em estoque
  • Fabricante: ABB

  • Nº do Produto: SPDSI22

  • País de origem:Suécia

  • Tipo de Produto: Digital Input Module

  • Código de barras: 85389081

  • Pagamento: T/T, Western Union

  • Peso: 850g

  • Dimensões: 410 mm x 320 mm x 110 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver informações completas

The ABB SPDSI22 is a high-density, high-performance Digital Input Module engineered for the Symphony Plus distributed control system architecture. Functioning as an integral component of the S+ HR I/O (Harmony Rack) range, the ABB SPDSI22 provides 16 universal digital input channels designed to monitor field contact states across varied voltage levels including 24 VDC, 48 VDC, 125 VDC, and 120 VAC. Equipped with 32 onboard hardware configuration jumpers, this module delivers elite field flexibility by allowing automation engineers to perform precise hardware selection for independent group-common routing, wetting voltage matching, and isolated circuit configurations directly on the printed circuit assembly.

Features

  • 16 Universal Input Channels: High-density architecture supports multiple field contact inputs within a single slot chassis profile.
  • Comprehensive Voltage Adaptability: Handles distinct threshold inputs across 24 VDC, 48 VDC, 125 VDC, and 120 VAC systems seamlessly.
  • 32 Hardware Configuration Jumpers: Onboard physical jumpers permit direct hardware modifications for loop routing and channel isolation.
  • Symphony Plus Backplane Interface: Direct coupling to the Harmony Rack communication bus guarantees real-time signal transmission and continuous module diagnostics.

Applications

  • Power generation plant substation status tracking, main breaker position reporting, and disconnect switch monitoring.
  • High-voltage 120 VAC or 125 VDC motor control center (MCC) safety feedback loop integration.
  • Sequence of Events (SOE) precision contact logging and safety interlocking networks in process industries.
  • Critical dry or wet field contact tracking under extreme electrical noise or ambient temperature constraints.

Technical Specifications

Manufacturer ABB
Product ID SPDS122
ABB Type Designation SPDS122 (SPDSI22 Software Profile)
Channel Type DI (Digital Input)
Number of Input Channels 16 Channels
Supported Input Voltages 24 VDC, 48 VDC, 125 VDC, 120 VAC
Hardware Adjustments 32 Selection Jumpers
Product Net Depth / Length 73.66 mm
Product Net Height 358.14 mm
Product Net Width 269.24 mm
Product Net Weight 0.85 kg (Calculated)
Package Dimensions 410 mm x 320 mm x 110 mm (Calculated)
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)
Customs Tariff Number / HS Code 85389081

Connections and Interfaces

Module Jumper Identification Functional Circuit Assignment & Jumper Mapping
Jumpers J1 through J16 Dedicated channel-level hardware routing blocks corresponding directly to digital input loops 1 to 16. Used to define configuration parameters for specific field return potentials.
Jumpers J17 through J32 Input threshold selection and secondary logic grouping paths. Determines isolation boundary limits and sets voltage classification settings across the field bus link.
Rear PCB Card-Edge Pins Connects directly to the Harmony Rack subrack communication bus. Signals are routed from the backplane assembly down to the physical terminal blocks on the paired external Termination Unit (TU).

Empirical Engineering Insights

Alternative Models & Compatibility

While catalog systems and logical design files list this asset under the model reference SPDSI22, the factory product tracking stamp explicitly identifies the hardware module code as SPDS122. These designations represent identical mechanical and electrical assemblies. When installing into existing systems, confirm your Composer software version supports the expanded multi-voltage attributes assigned to the module layout.

Application Pitfalls & Engineering Notes

When deploying this module for high-voltage monitoring, specifically 125 VDC or 120 VAC loops, internal power dissipation via the circuit's current-limiting resistors increases significantly. If multiple adjacent channels remain continuously energized under maximum voltage parameters within unventilated control enclosures, thermal build-up can accelerate component degradation. Maintain proper vertical cooling clearance around the Harmony Rack frame.

Commissioning & Wiring Tips

The 32 onboard configuration jumpers must be physically set and audited utilizing long-nose pliers prior to sliding the card into the live chassis slot. Running a high-voltage loop into a channel jumpered for a 24 VDC circuit path can lead to immediate optocoupler failure or trace damage. Field wiring terminal mapping is dictated entirely by the type of external Symphony Plus Termination Unit (TU) mated to the slot location.

Installation Guidelines

CRITICAL WARNING: Isolate all field wetting supplies and lock out external high-voltage signals (especially 120 VAC or 125 VDC connections) before handling the module. Inserting or extracting an incorrectly jumpered card under live loop conditions can cause cross-conduction, dangerous arc flashes, or localized logical bus damage.
1
Cross-reference loop schematic drawings and set all 32 configuration jumpers to match the intended channel input voltages before insertion.
2
Align the top and bottom edges of the printed circuit board assembly evenly with the guide rails inside the assigned subrack slot.
3
Push the module backward smoothly until the card-edge interface registers and fully couples with the rear backplane data bus.
4
Tighten the module front-plate captive screws completely to verify frame grounding continuity and prevent loose connections under field vibration.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB SPDSI22 Symphony Plus Digital Input Module

Loading PDF, please wait…

Why does my module display the product identifier SPDS122 instead of SPDSI22?

The physical hardware label reads SPDS122, which corresponds directly to the functional module definition software profile referred to as SPDSI22 within your control system engineering environment.

How do the 32 selection jumpers split across the 16 input channels?

Jumpers J1 through J16 manipulate dedicated configuration paths for individual digital input channels 1 to 16, while jumpers J17 through J32 define internal threshold routing and circuit loop references.

Can I process a mix of both AC and DC voltages on a single card?

Yes. Because every channel can be adapted independently via its corresponding onboard jumper pins, you can manage varied input profiles provided they follow proper isolation constraints outlined in your termination unit drawings.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Color pattern
Verde
Country of origin
Suécia
Power source
Energia CC Alimentado por energia AC

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...