AH64AN02P-5C DELTA AH500 Series 64-Point Digital Output Module

AH64AN02P-5C DELTA AH500 Series 64-Point Digital Output Module

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: AH64AN02P-5C

  • Country of origin:Estados Unidos

  • Product Type: 64-point Digital I/O Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantidade
Ver informações completas

Product Overview

The AH64AN02P-5C (AH64AN02P5C) is a high-density digital output module designed for Delta’s AH500 modular PLC system. This module provides 64 integrated output points, utilizing PNP (Source) logic to drive industrial field devices such as solenoid valves, pilot lights, and interposing relays. Engineered for large-scale automation projects where cabinet space is at a premium, the AH64AN02P-5C utilizes latched connectors for efficient wiring and supports hot-swapping, allowing the module to be replaced without shutting down the entire system. With built-in diagnostic features like the "keep-last-value" function, this module ensures process stability even during CPU transitions or maintenance events.

Technical Configuration

The AH64AN02P-5C hardware is optimized for high-reliability signal distribution. Each of the 64 points is rated for 12 to 24 VDC at 0.1 A, making it ideal for driving high-impedance loads and electronic inputs. The unit features 32 individual LED status indicators that can be toggled to monitor all 64 points in banks, providing instant local diagnostics. A critical safety feature is the Keep-Last-Value function, which allows the user to configure whether outputs should turn off or maintain their current state if the CPU enters a STOP mode or loses communication. For wiring efficiency, the module is designed to interface with external terminal blocks via specialized ribbon cables (DVPACAB series), significantly reducing manual point-to-point wiring time.

Technical Specifications

Attribute Specification Details
Model AH64AN02P-5C
Brand DELTA
Series AH500 Series
Points 64
Signal Type Digital Output (PNP / Source)
Operating Voltage 12 to 24 VDC
Output Current 0.1 A per point
Power Consumption 0.6 W (Internal) / 1.5 W (External)
Terminal Block Type Latched Connector (Mil-Spec)
Special Functions Hot-swapping, Keep-last-value
Status Indicators 32 LEDs (switchable for 64 points)
Shipping Weight 2.0 kg

Technical FAQs

What is the benefit of the "Keep-Last-Value" function?

In specific industrial processes, a sudden loss of control signal can be hazardous (e.g., stopping a cooling fan or closing a critical valve). The AH64AN02P-5C allows the hardware to "latch" the last known state from the CPU, ensuring the field device stays in its safe orientation until manual intervention or a system reboot occurs.

Does the module support hot-swapping?

Yes. As part of the AH500 architecture, the AH64AN02P-5C can be removed and replaced while the backplane is powered and the rest of the PLC is running. This is a vital feature for high-availability manufacturing environments where stopping the entire line for a single module replacement is not feasible.

How do I manage the wiring for 64 points with a latched connector?

Delta provides pre-assembled cable and terminal block sets (sold separately). For this module, you can use two DVPACAB7B10 cables connected to four DVPAETB-OR16B relay boards, or two DVPACAB7A10 cables connected to two DVPAETB-OT32A terminal blocks. This modular approach ensures a "plug-and-play" installation with minimal chance of wiring errors.


Engineering & Installation Guide

  • Load Management: The 0.1 A rating per point is designed for logic signals and small solenoids. If you need to drive high-current loads (e.g., large contactors or motors), always use an external interposing relay board. Exceeding the 0.1 A limit can cause thermal damage to the internal transistor arrays.

  • External Power Supply: Ensure a stable 24 VDC power supply is connected to the external power terminals of the module. Since the module drives 64 points, a voltage drop on the external line can cause erratic behavior of the connected field devices. Use a dedicated industrial-grade power supply for I/O loads.

  • Hot-Swap Safety: When hot-swapping the AH64AN02P-5C, ensure the latched connector is fully disengaged before pulling the module from the rack. When inserting the new module, press firmly until the locking tabs click into place to ensure a solid connection to the AH500 high-speed backplane.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Branco Acinzentado
Country of origin
Estados Unidos
Power source
Energia CC

Recently Viewed Products

Technical knowledge

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...

Configuração de Controle de Movimento de Eixo Único com Drives Servo CMZ

Este tutorial explora a comissionamento de um sistema de movimento servo de eixo único usando um drive CMZ SBD, abrangendo a configuração de hardware, escala do eixo, configuração de homing e...