BECKHOFF BX8000 BX Series RS232/RS485 Bus Terminal Controller

BECKHOFF BX8000 BX Series RS232/RS485 Bus Terminal Controller

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: BX8000

  • País de origem:Alemanha

  • Tipo de Produto: Bus Terminal Controllers

  • Pagamento: T/T, Western Union

  • Peso: 250g

  • Dimensões: 61 mm x 100 mm x 90 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Integrating decentralized execution with flexible communication capabilities, the BECKHOFF BX8000 functions as a high-performance programmable logical controller designed for the Beckhoff Bus Terminal system. This compact controller bridges standard serial communication interfaces (RS232 and RS485) with industrial I/O signals, enabling modular control topologies in complex plant installations. Engineered with 256 kbytes of program memory and 256 kbytes of data memory, it provides robust capabilities for execution tasks configured via the TwinCAT software suite in compliance with the IEC 61131-3 standard.

The unit features a built-in illuminated FSTN character display alongside an integrated navigation joystick, allowing operators to execute diagnostic functions, configure network parameters, and read localized status messages directly at the device. Connectivity is further enhanced by an integrated CANopen-based Smart System Bus (SSB) designed to link additional peripheral modules or subsidiary controller units.

Features

  • Dual integrated serial interfaces: COM1 configured as dedicated RS232; COM2 configurable as RS232 or RS485.
  • Direct connection for up to 64 local Bus Terminals, expandable to a maximum of 255 modules utilizing K-bus extension technology.
  • Illuminated FSTN display showing 2 lines of 16 characters for customized status tracking and system diagnostics.
  • IEC 61131-3 compatible programming support with capability for online program alterations.
  • Battery-backed integrated real-time clock for system time-stamping and scheduling tasks.
  • Integrated power contacts rating of up to 24 V DC at 10 A max.

Applications

  • Distributed machinery control and local pre-processing.
  • Serial-to-fieldbus gateway execution in infrastructure monitoring.
  • HVAC and building automation networks using Modbus RTU protocols.
  • Remote telemetry and processing stations requiring local status displays.

Technical Specifications

Technical ParameterSpecification Value
Manufacturer BECKHOFF
Part Number / Model BX8000
Programming System TwinCAT (via programming interface or fieldbus)
Program Memory 256 kbytes
Data Memory 256 kbytes
Remanent Data 2 kbytes
Persistent Data 1 kbyte
Programming Languages IEC 61131-3 (IL, LD, FBD, SFC, ST)
Serial Interfaces COM1: 1 x RS232; COM2: 1 x RS232 or RS485
Data Transfer Rates 300 baud to 115 kbaud
Subsidiary Bus (SSB) CANopen-based expansion bus
Local I/O Capacity 64 Bus Terminals (up to 255 with K-bus extension)
Power Supply 24 V DC (-15% / +20%)
Input Current 140 mA + (total K-bus current)/4, max 500 mA
K-bus Current Supply 1450 mA
Electrical Isolation 500 V (power contact / supply voltage)
Display FSTN illuminated, 2 lines x 16 characters
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, non-condensing
Protection Rating IP20
Dimensions (W x H x D) 61 mm x 100 mm x 90 mm
Weight approx. 250 g

Connections and Interfaces

Interface PortDescription & Functionality
COM1 Dedicated RS232 connection for configuration and diagnostics
COM2 Selectable RS232 or RS485 serial communication port
SSB CANopen-based interface for external peripheral extension
K-bus Power Contacts Internal connection delivering up to 1450 mA to adjacent I/O cards

Installation Guidelines

  • Mounting: Mount horizontally on standard 35 mm DIN rail (conforming to EN 60715) using the integrated locking mechanism.
  • Wiring: Connection terminals utilize tool-actuated spring clamps. Solid conductors (0.08 to 2.5 mm squared) and flexible conductors with wire-end ferrules (0.14 to 1.5 mm squared) should be stripped to a length of 8 to 9 mm prior to insertion.
  • Shielding & Grounding: Ensure a low-impedance connection to the functional earth terminal to safeguard against serial interface EMC disturbances.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

How is the BECKHOFF BX8000 programmed?

The BX8000 is programmed via the Beckhoff TwinCAT system, using standard IEC 61131-3 programming languages such as Instruction List (IL), Ladder Diagram (LD), Function Block Diagram (FBD), Sequential Function Chart (SFC), and Structured Text (ST).

What serial communication standards does the BX8000 controller support?

The controller features two serial interfaces: COM1 is configured as a dedicated RS232 port, while COM2 can be configured as either an RS232 or an RS485 interface, supporting baud rates ranging from 300 baud up to 115 kbaud.

What is the maximum expansion capacity for local Bus Terminals?

Directly, the BX8000 supports up to 64 local Bus Terminals. This can be expanded up to 255 terminals by utilizing a K-bus extension system.

What are the physical dimensions of the BX8000?

The compact controller housing measures 61 mm in width, 100 mm in height, and 90 mm in depth, with a weight of approximately 250 grams.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...