1 de 1

Beckhoff CX1020-0123 CX Series Basic CPU Module

Beckhoff CX1020-0123 CX Series Basic CPU Module

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: CX1020-0123

  • País de origem:Alemanha

  • Tipo de Produto: Basic CPU Modules

  • Pagamento: T/T, Western Union

  • Peso: 500g

  • Dimensões: 96 mm x 112 mm x 99 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Executing complex automation tasks requiring dedicated industrial performance, the Beckhoff CX1020-0123 acts as the central execution engine of the modular CX control system. Driven by an Intel Celeron M ULV processor operating at a stable 1 GHz clock frequency, this embedded controller delivers high-speed deterministic control and connectivity in a compact, DIN-rail mounted footprint. The unit is optimized for integrated PC-based control, featuring an execution architecture designed directly for TwinCAT 2 NC I environments. Complete with dual Ethernet RJ45 ports and modular expansion interfaces, this Basic CPU Module ensures seamless integration with standard Beckhoff I/O terminals and power delivery units.

Features

  • Intel Celeron M Processor: Ultra-Low Voltage (ULV) processor architecture running at 1 GHz for fanless, energy-efficient operation.
  • Modular Memory Configuration: Features 256 MB of high-speed DDR RAM alongside a dedicated external Compact Flash Type I+II slot with eject mechanism.
  • Dual Ethernet Routing: Outfitted with 2 x RJ45 10/100 Mbit/s ports connected via an internal switch for linear or star physical network topologies.
  • TwinCAT Integration: Factory pre-installed with Windows Embedded Standard 2009 supporting the TwinCAT 2 NC I runtime for coordinated point-to-point motion execution.
  • Flexible I/O Interface: Connects to Beckhoff E-bus or K-bus I/O systems dynamically through compatible CX1100-xxxx series power supply modules.

Applications

  • Multi-axis coordinated motion control and packaging machinery.
  • Centralized plant automation systems requiring deterministic EtherCAT execution.
  • Embedded visualization, human-machine interface (HMI), and data gateway applications.
  • Test benches and laboratory automation setups requiring sub-millisecond task times.

Technical Specifications

Parameter Value
Manufacturer Beckhoff Automation
Model / Article Number CX1020-0123
Processor Type Intel Celeron M ULV (1 GHz, 1 Core)
Main Memory 256 MB DDR RAM (expandable)
Flash Memory Compact Flash Slot (128 MB CF card included)
Interfaces 2 x RJ45 10/100 Mbit/s (internal switch)
Diagnostics Power, LAN link/activity, TC status, flash access
Expansion Slot 1 x Compact Flash Type I + II with eject mechanism
System Bus Connection 16-bit ISA (PC/104)
Operating System Windows Embedded Standard 2009
Control Software TwinCAT 2 NC I runtime
Power Supply Via system bus (through external CX1100-xxxx module)
Max. Power Consumption 11 W
Dimensions (W x H x D) 96 mm x 112 mm x 99 mm
Operating Temperature 0 to +50 degC (no condensation)
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
Protection Rating IP20
Net Weight 550 g
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Port / Interface Type Function Assignment
LAN 1 (X101) RJ45 (10/100 Mbit/s) Industrial Ethernet / TwinCAT Real-time communication (Port 1)
LAN 2 (X102) RJ45 (10/100 Mbit/s) Industrial Ethernet / TwinCAT Real-time communication (Port 2)
Compact Flash Slot CF Type I+II Insert System drive storage / Non-volatile registry and application file storage
System Bus (Right Side) 16-Bit PC/104 ISA Direct communication and power bus link to CX1100 power supply module

Alternative Models & Compatibility

The CX1020-0123 CPU module requires a corresponding power supply module from the CX1100 series (e.g., CX1100-0001 for K-bus or CX1100-0003 for E-bus/EtherCAT terminals) for direct bus communication. Replacing older, non-switch Ethernet CX series models requires updating system configurations within TwinCAT. Note that the memory options (256 MB vs. 1 GB) and OS variant (Windows Embedded Standard 2009 vs. Windows CE) must be matched carefully if migrating existing control programs to prevent execution faults.

Application Pitfalls & Engineering Notes

This system relies on convective cooling. Horizontal mounting is strictly forbidden as it disrupts thermal airflow, leading to localized heating and automatic hardware thermal throttling. When designing control cabinets, verify that at least 30 mm of free spatial clearance is left above and below the CX module. To ensure flash memory longevity, always enable the Enhanced Write Filter (EWF) or File-Based Write Filter (FBWF) within the OS to redirect unnecessary log-writes away from the Compact Flash card.

Commissioning & Wiring Tips

Before powering up the system for the first time, ensure the Compact Flash card is firmly seated with its locking mechanism closed. Do not hot-swap or eject the card while the green disk-access LED is lit, as this can result in total system drive corruption. Always complete physical bus configurations (connecting K-bus or E-bus terminals) when the entire rack is fully de-energized.

Installation Guidelines

CRITICAL WARNING

Disconnect all power sources and verify that no residual voltage remains on the system bus before installing or removing modules. Failure to de-energize the assembly can cause permanent electrical damage to the PC/104 system bus, the main CPU, and connected I/O terminals.

1

Mount the CX1020-0123 CPU module onto a standard 35 mm DIN rail (EN 60715) with vertical orientation.

2

Push the CPU module firmly to the left along the rail to lock its integrated PC/104 system bus connector into the adjacent CX1100 power supply module.

3

Insert the formatted Compact Flash card into the dedicated front expansion slot, ensuring it snaps securely into place.

4

Connect network and communication lines to the RJ45 interfaces, ensuring proper shield grounding on the cables.

Loading product navigation…

Can this CPU module run standalone without a power supply module?

No. The CX1020-0123 requires a system-connected CX1100 series power supply module (such as CX1100-0001, -0002, or -0003) to power the internal PC/104 bus and interface with standard I/O blocks.

How do I prevent file system corruption on the Compact Flash card?

You should enable the OS-integrated Enhanced Write Filter (EWF) or File-Based Write Filter (FBWF). This minimizes write fatigue by redirecting temporary file alterations directly to system RAM.

What software environment does this CPU support?

This module comes preconfigured with Windows Embedded Standard 2009 and is designed to host the TwinCAT 2 NC I runtime control software.

What mounting orientation is required for proper thermal performance?

It must be mounted vertically on a standard 35 mm DIN rail. Horizontal mounting is prohibited as it blocks the internal convective cooling airflow, resulting in thermal throttling.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...