1 de 1

Beckhoff CX2550-0179 CX2000 Series USB Extender Transmitter Module

Beckhoff CX2550-0179 CX2000 Series USB Extender Transmitter Module

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: CX2550-0179

  • País de origem:Alemanha

  • Tipo de Produto: USB Extender Modules

  • Pagamento: T/T, Western Union

  • Peso: 500g

  • Dimensões: 24 mm x 99 mm x 54.5 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Providing extended local system expansion directly from the CX2000 Embedded PC series, the Beckhoff CX2550-0179 functions as a high-reliability transmitter module for USB signals. This unit transmits USB 1.1 data packets over extensive plant floor runs, facilitating a secure link between the central processor and a remote operator interface such as the CP69xx-xxxx-0000 series control panels. By utilizing the proprietary USB Extended technology, it eliminates the need for active signal repeaters while maintaining deterministic communication.

Key Features

  • Direct physical and electrical integration with the left-side system connection of CX20xx Embedded PCs.
  • Transmission of USB 1.1 signals up to a maximum distance of 50 meters.
  • Utilizes standard, cost-effective Cat.5E shielded twisted-pair cabling for physical transport.
  • Integrated RJ45 connection socket designed for high mechanical retention in high-vibration panels.
  • Zero-configuration operation via system bus power routing, requiring no external power supply wiring.
  • Four diagnostic LEDs providing direct status visibility for Power, Speed, +15 V, and Suspend states.

Applications

  • Decentralized visualization panels (CP69xx-xxxx-0000) mounted on machine swing arms.
  • Remote human-machine interfaces (HMI) located away from high-noise electrical cabinets.
  • Long-range peripheral configuration and diagnostic ports in assembly lines.

Technical Specifications

Specification Parameter Value / Details
Manufacturer Beckhoff Automation
Model Number CX2550-0179
Interface Type 1 x USB Extended 1.1 Transmitter
Physical Connection RJ45 Shielded Socket
Transmission Distance Max. 50 m via Cat.5E cable
Power Supply Via system bus (powered through CX2100-0xxx power supply modules)
LED Diagnostics 1 x Power, 1 x Speed, 1 x +15 V, 1 x Suspend
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Dimensions (W x H x D) 24 mm x 99 mm x 54.5 mm
Net Weight 190 g
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Empirical Engineering Insights

Alternative Models & Compatibility

The CX2550-0179 is designed exclusively as a USB 1.1 transmitter. If your target peripheral or remote HMI requires USB 2.0 speeds (e.g., for external storage, heavy file transfers, or modern touch controllers requiring USB 2.0 bandwidth), the CX2550-0079 should be used instead. Note that the transmitter module must always match the capability of the receiver card built into the CP69xx control panel series.

Application Pitfalls & Engineering Notes

When calculating thermal dissipation inside compact, unventilated electrical cabinets, factor in the 190 g modules continuous heat output alongside the main CX CPU module. To ensure consistent signal integrity, avoid parallel routing of the Cat.5E connection cable with high-voltage AC motor drives or heavy contactor supply lines. While the unit complies with EN 61000-6-2 industrial immunity standards, severe electromagnetic fields can trigger transient packet drops, causing the 'Suspend' LED to toggle.

Commissioning & Wiring Tips

Always utilize STP (Shielded Twisted Pair) Cat.5E cabling with fully metal-shielded RJ45 plugs. Ensure the metal shielding on the cable makes direct contact with the grounding shroud of the RJ45 socket on both the CX2550-0179 transmitter and the receiver unit. If the grounding path is compromised, electrostatic build-up may cause communication interruptions or require a cold reboot of the CX20xx controller.

Installation Guidelines

CRITICAL WARNING:

Do not install or remove the CX2550-0179 transmitter module while the central control system is powered. Ensure the primary CX2100-0xxx power supply module is completely de-energized and wait at least 30 seconds for all residual capacitance to bleed down before mechanical mounting. Failure to comply can result in permanent damage to the multi-pin PC/104 system bus interface.

1
Disconnect all power from the main control panel and verify that the system is safe to touch.
2
Align the CX2550-0179 guide pins with the left-hand expansion connector of the CX20xx CPU module.
3
Press the two units together gently until the locking mechanism fully clicks, verifying a gap-free fit.
4
Insert the shielded Cat.5E patch cable into the RJ45 port until it locks in place, ensuring the cable strain relief is secure.
5
Re-energize the power supply module. Confirm the Power and diagnostic LEDs light up, indicating communication initialization with the TwinCAT platform.
Loading product navigation…

What is the maximum cable distance supported by the CX2550-0179?

The CX2550-0179 transmitter module supports a maximum transmission distance of up to 50 meters when using a standard high-quality Cat.5E or higher shielded copper Ethernet cable.

Does this module support USB 2.0 or USB 3.0 devices?

No, this module is strictly designed for USB 1.1 protocol rates. For applications requiring USB 2.0 standard bandwidth and speeds, you must utilize the CX2550-0079 module.

Does the CX2550-0179 require a dedicated external power supply wiring?

No, the module is powered directly from the internal system bus of the host controller, drawing its working current through the integrated connection interface of the CX2100 power supply.

What do the diagnostics LEDs indicate on the front panel of the module?

The module features four active status LEDs: 'Power' indicates general internal voltage presence, 'Speed' reflects active data transmission, '+15 V' confirms correct voltage supply to the interface circuitry, and 'Suspend' illuminates when the connected USB device enters low-power standby mode.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...