1 de 1

Beckhoff CX5140-N031-0004 CX5100 Series Embedded PC

Beckhoff CX5140-N031-0004 CX5100 Series Embedded PC

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: CX5140-N031-0004

  • País de origem:Alemanha

  • Tipo de Produto: Embedded PC Modules

  • Pagamento: T/T, Western Union

  • Peso: 500g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Engineered for high-performance automation tasks requiring compact DIN-rail mounting, the Beckhoff CX5140-N031-0004 represents an industrial-grade controller equipped with an Intel Atom quad-core processor. This unit integrates a dedicated N031 RS422/RS485 serial option interface, allowing full-duplex communication endpoints directly from the processor assembly. Designed to operate without a fan, the device leverages passive cooling architecture to deliver robust execution of TwinCAT control tasks, making it ideal for high-speed PLC, motion control, and communication gateway applications.

Key Features

  • Intel Atom Quad-Core Processor: Delivers high-speed, multi-core computational power optimized for real-time automation sequences and deterministic control loops.
  • N031 Serial Interface: Standard 9-pin D-sub female socket configured for RS422/RS485 operation as a terminated full-duplex end point.
  • Dual Gigabit Ethernet Ports: Dual independent RJ45 interfaces supporting 10/100/1000 Mbps for separated network topologies and control communication.
  • Universal I/O Connectivity: Automatic detection and bus-switching support for either EtherCAT Terminals (E-bus) or standard Bus Terminals (K-bus).
  • Robust Maintenance-Free Design: Fanless operations with solid-state storage media compatibility, minimizing mechanical failure risks in harsh environments.

Industrial Applications

  • High-Speed Packaging Machinery: Serves as the primary motion control platform coordinating multi-axis synchronized drives via EtherCAT.
  • Process Control Gateways: Bridges legacy field networks utilizing the RS422 serial interface to modern EtherCAT or TCP/IP enterprise layers.
  • Wind Energy & Power Generation: Performs deterministic turbine control and structural monitoring under broad temperature variances.
  • Distributed Building Automation: Coordinates lighting, HVAC, and subsystem integration across expansive physical facilities.

Technical Specifications

Specification Parameter Value / Description
Manufacturer Beckhoff
Model Number CX5140-N031-0004
Processor Intel Atom (1.91 GHz, Quad-Core)
Memory Config 4 GB DDR3 RAM (Internal, non-expandable)
Serial Interface (N031) RS422 / RS485 (9-pin D-sub, female)
Ethernet Interfaces 2 x RJ45 (10/100/1000 Mbit/s, independent)
USB Ports 4 x USB 2.0
Display Interface 1 x DVI-D
Bus System Connection E-bus (EtherCAT) or K-bus (standard terminal bus) automatic detection
Operating Voltage 24 V DC (-15% / +20%)
Operating Temperature -25 degC to +60 degC
Shipping Weight (Calculated) 3.00 kg

Connections and Interfaces

The N031 option provides a serial interface configured for full-duplex RS422 end point operation with internal termination resistors engaged. The connection is made via a 9-pin D-sub female connector with the following pin assignments:

D-sub Pin Signal Assignment (RS422 Full Duplex)
Pin 2 TxD+ (Transmit Data +)
Pin 3 RxD+ (Receive Data +)
Pin 5 GND (Signal Ground)
Pin 7 TxD- (Transmit Data -)
Pin 8 RxD- (Receive Data -)

Empirical Engineering Insights

Alternative Models & Compatibility

The CX5140-N031-0004 can direct-replace standard CX5140-0004 systems, provided that any system-level application profiles are updated in TwinCAT System Manager to map the virtual COM port allocated to the N031 serial chip. Note that changing physical terminal bus attachments from standard K-bus to E-bus does not require manual hardware switching, as the internal controller automatically queries and initiates the correct physical layer driver upon boot.

Application Pitfalls & Engineering Notes

Because the N031 interface features non-switchable internal terminating resistors, adding external termination blocks at the controller end of the RS422 bus segment will result in excessive signal loading. Double-termination at the local node can degrade communication signal margins, resulting in sporadic CRC or framing errors, particularly when operating at high baud rates over long distances.

Commissioning & Wiring Tips

When routing serial links beside high-voltage motor cables, verify that the 9-pin D-sub metallic hood makes robust, continuous 360-degree connection to the cable shield. Ensure that shield ground is connected only at a single ground bus reference inside the primary enclosure to block ground loop currents from traversing the communication lines.

Installation Guidelines

CRITICAL WARNING

Isolate and completely shut down all primary and auxiliary 24 V DC power sources before mounting or dismounting the CPU block. Attempting to couple or uncouple bus terminals (E-bus/K-bus) with power applied will generate transient voltage spikes that can permanently ruin the electronic backplane logic.

1
Mount the device onto a standard 35 mm DIN rail (EN 60715) by pressing the integrated locking tab downwards, positioning the unit against the rail, and letting the tab latch back into position securely.
2
Align adjacent E-bus/K-bus terminals to the right-hand interface, pushing them together until the physical interlocking lock latches click.
3
Establish the power system and serial connections using insulated 24 V DC power cables with a nominal wire cross-section of at least 1.0 mm² to limit transmission drop voltage under high CPU loads.
Loading product navigation…

What is the function of the N031 option code on this Embedded PC?

The N031 option designates an integrated serial port configured as an RS422/RS485 interface via a 9-pin D-sub socket. It operates as a full-duplex end point with internal termination enabled.

Which software environments are compatible with this CX5140 module?

This hardware revision is optimized for the TwinCAT 3 runtime environment under Windows Embedded Compact 7, enabling real-time control, PLC, and motion control configurations.

How does the unit handle I/O terminal connections?

The controller features a direct backplane interface that automatically detects and communicates with either EtherCAT Terminals (E-bus) or Bus Terminals (K-bus).

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...