1 de 1

Beckhoff EL1918-2200 TwinSAFE EtherCAT Terminal 8-channel Digital Input

Beckhoff EL1918-2200 TwinSAFE EtherCAT Terminal 8-channel Digital Input

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: EL1918-2200

  • País de origem:Alemanha

  • Tipo de Produto: TwinSAFE Safety Terminals

  • Pagamento: T/T, Western Union

  • Peso: 2000g

  • Dimensões: 12 mm x 100 mm x 68 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed to integrate directly into the EtherCAT I/O system, the Beckhoff EL1918-2200 is an ultra-compact TwinSAFE terminal engineered for the decentralized connection of safety-related sensors. This 8-channel digital input module transmits safe signals via Safety over EtherCAT (FSoE) to a TwinSAFE Logic-capable component, enabling reliable execution of safety functions in complex industrial automation architectures. Featuring 1-wire or 2-wire connection technology, the module combines high-density packaging with robust processing diagnostics to meet strict global safety metrics.

Key Features

  • 8 Fail-Safe Digital Inputs: Supports direct connection of safe sensors and contacts.
  • FSoE Protocol Integration: Operates seamlessly via TwinSAFE / Safety over EtherCAT communication.
  • Flexible Wiring: Compatible with both 1-wire and 2-wire termination schemes.
  • High-Density Housing: 12 mm width optimizes valuable DIN rail footprint.
  • Status Diagnostics: Dedicated LED status indicators on the front panel for bus communication and error tracking.

Applications

  • Automotive Assembly Lines: Interlocking safety gates, light curtains, and emergency stop circuits.
  • Robotic Cells: Processing safe position feedback and functional safety signals.
  • Material Handling Systems: Distributed emergency-off systems over extended physical networks.
  • Packaging Machinery: Multi-axis safety zone management and guard monitoring.

Technical Specifications

Parameter Value / Specification
Manufacturer Beckhoff
Model Number EL1918-2200
Safety Standards EN ISO 13849-1:2015 (Cat. 4, PL e), EN 61508:2010 (SIL 3)
Protocol TwinSAFE / Safety over EtherCAT (FSoE)
Number of Safe Inputs 8
Connection Technology 1-/2-wire
Fault Response Time ≤ watchdog time (parameterizable)
E-bus Current Consumption typ. 165 mA
Power Contacts Current Load max. 10 A
IP Protection Rating IP20
Housing Material Polycarbonate (HD housing)
Solid Wire Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Stranded Wire Cross-Section 0.25 to 1.5 mm² (AWG 22 to 16)
Ferrule Wire Cross-Section 0.14 to 0.75 mm² (AWG 26 to 19)
Stripping Length 8 to 9 mm
Net Weight approx. 50 g
Shipping Weight (Calculated) 0.15 kg (single unit packaging)
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm

Empirical Engineering Insights

Alternative Models & Compatibility

While the standard EL1908 offers 8 digital inputs, the EL1918-2200 variant utilizes high-density termination for complex safety mapping and features optimized processing logic parameters. Note that this terminal requires a valid TwinSAFE Logic master (such as an EL6910 or a TwinCAT safety PLC configuration) to execute safe logic functions. Compatibility requires TwinCAT 3.1 or higher for optimal parameter configuration and FSoE protocol handling.

Application Pitfalls & Engineering Notes

A major deployment hazard involves E-bus power budgeting. The EL1918-2200 consumes typically 165 mA from the E-bus. In large nodes populated with multiple safety or analog slices, the internal 5V supply line can quickly saturate. Always recalculate your E-bus current draw in TwinCAT System Manager; insert an EL9410 power supply terminal if the total current exceeds the couplers capacity (typically 2A for standard EtherCAT couplers).

Commissioning & Wiring Tips

When wiring the High Density (HD) spring connections, ensure that ferrules are crimped square and do not exceed 0.75 mm². Use a specialized flat-blade screwdriver to actuate the spring contacts for stranded conductors without pre-crimped ferrules. Keep the stripping length strictly between 8 and 9 mm to avoid exposing bare copper or preventing full contact seating, which can cause intermittent safety channel faults.

Installation Guidelines

CRITICAL WARNING: De-energize the entire control cabinet before inserting or removing the terminal. Failure to do so can cause permanent damage to the internal E-bus transceiver and could initiate unintended safety-system activations or system faults.
1
Mount the terminal onto a standard 35 mm DIN rail (conforming to EN 60715). Align the integrated double slot-and-key connection with adjacent terminals and press down until you hear a secure click.
2
Secure the terminal assembly horizontally using an end bracket to prevent lateral shifting during operation under high vibration.
3
Connect safe sensors using either 1-wire or 2-wire architectures. Standard solid-core wires can be pushed directly into the contact terminal without tool actuation.
4
Power up the system and verify the status LEDs. Configure safety addresses, watchdog parameters, and input mapping via TwinCAT Safety Editor before operational commissioning.
Loading product navigation…

What is the primary function of the Beckhoff EL1918-2200 terminal?

The terminal is an 8-channel digital fail-safe input module designed for decentralized sensor evaluation. It transfers safety-relevant digital signals via FSoE (Safety over EtherCAT) to a TwinSAFE logic controller.

Does the EL1918-2200 require external logic to execute safety functions?

Yes. The module acts purely as an input terminal. It must communicate with a safety logic master, such as an EL6910 TwinSAFE Logic terminal or a software-based safety PLC, to process safety logic.

What are the E-bus current consumption requirements for this safety module?

The module typically consumes 165 mA from the E-bus. Ensure your EtherCAT coupler or auxiliary power terminal (such as an EL9410) has sufficient current headroom.

Which safety standards are supported by this digital input terminal?

It is certified for applications requiring safety performance levels up to Category 4, PL e according to EN ISO 13849-1:2015, and SIL 3 in compliance with EN 61508:2010.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Transformaram a Mineração Subterrânea

Desde compressores CC acionados por corda até carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como...