Description

Facilitate seamless bidirectional data transmission between serial devices and high-level control architectures using the Beckhoff EL6002 EtherCAT terminal. This 2-channel serial communication interface enables the direct connection of up to two serial RS232 devices to the standard EtherCAT network. It integrates smoothly into decentralized systems, permitting flexible configuration of transmission parameters such as baud rate, parity, and stop bits directly via the EtherCAT master controller, eliminating the need for manual DIP switch configurations.

The unit features 500 V electrical isolation between the E-bus backplane and the RS232 signal lines to prevent ground loop damage and signal degradation in demanding industrial settings. Packaged in a compact housing, this module contains internal data buffers to ensure reliable asynchronous data transfer even under heavy system load.

Features

  • Two independent serial RS232 communication channels.
  • Standard 9-pin D-sub connectors for reliable physical terminal interface connections.
  • Flexible data transfer rates ranging from 300 to 115,200 baud.
  • Integrated data buffer with 864 bytes of receive buffer and 128 bytes of transmit buffer.
  • Direct power supply routing through the E-bus backplane.
  • Compact 24 mm housing with built-in signal status LEDs for simplified on-site diagnostic checks.

Applications

  • Integrating serial barcode readers, weight scales, and labeling machines.
  • Connecting legacy human-machine interfaces (HMIs) to EtherCAT systems.
  • Interfacing custom manufacturing instruments and specialized process sensors.
  • Decentralized industrial automation and general machinery control.

Technical Specifications

Manufacturer Beckhoff
Part Number/Model EL6002
Connection Technology 9-pin D-sub
Number of Channels 2
Interfaces 2 x RS232
Data Transfer Rates 300 to 115,200 baud (Default: 9600 baud, 8 data bits, no parity, 1 stop bit)
Cable Length Max. 15 m
Power Supply Via the E-bus
Current Consumption E-bus Typically 170 mA
Electrical Isolation 500 V (E-bus / signal voltage)
Data Buffer 864 bytes receive buffer, 128 bytes transmit buffer
Configuration No address setting required; configuration via the controller
Material Polycarbonate
Housing Design Compact terminal housing with signal LEDs
Dimensions (W x H x D) 24 mm x 100 mm x 52 mm
Weight Approx. 55 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable

Connections and Interfaces

Connector Pin Standard RS232 Function (Typical Configuration)
Pin 1 DCD (Data Carrier Detect)
Pin 2 RxD (Receive Data)
Pin 3 TxD (Transmit Data)
Pin 4 DTR (Data Terminal Ready)
Pin 5 GND (Signal Ground)
Pin 6 DSR (Data Set Ready)
Pin 7 RTS (Request to Send)
Pin 8 CTS (Clear to Send)
Pin 9 RI (Ring Indicator)

Installation Guidelines

  • Mount the module onto a standard 35 mm DIN rail conforming to EN 60715 using the locking mechanism.
  • Ensure proper side-by-side terminal mounting by utilizing the double slot and key connection mechanics.
  • Observe IP20 protection guidelines; prevent moisture, excessive dust, and conductive particles from entering the enclosure.
  • Prior to wiring or installation, isolate the electrical system from all live power sources.

Compliance and Certifications

  • CE
  • UL
  • ATEX
Loading product navigation…

What data transfer rates are supported by the Beckhoff EL6002?

The EL6002 supports baud rates ranging from 300 to 115,200 baud. The default setting is 9600 baud, 8 data bits, no parity, and one stop bit.

How is the EL6002 module powered?

The module is powered internally through the E-bus backplane of the Beckhoff EtherCAT system, consuming a typical current of 170 mA.

What is the physical connection interface used by the EL6002?

It features two standard 9-pin D-sub connectors (RS232 interface) for direct and secure physical connection.

Is electrical isolation provided on this serial interface?

Yes, the EL6002 features 500 V of electrical isolation between the E-bus and the RS232 signal lines to prevent damage from potential differences.

What certificates does the EL6002 hold?

The module complies with CE, UL, and ATEX standards for industrial deployment.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...