1 de 1

Beckhoff EL9222-4433 EtherCAT Terminal 2-Channel Overcurrent Protection Module

Beckhoff EL9222-4433 EtherCAT Terminal 2-Channel Overcurrent Protection Module

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: EL9222-4433

  • País de origem:Alemanha

  • Tipo de Produto: Overcurrent Protection Terminals

  • Pagamento: T/T, Western Union

  • Peso: 2000g

  • Dimensões: 12 mm x 100 mm x 68 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed to safeguard critical 24 V DC control circuits within EtherCAT industrial networks, the Beckhoff EL9222-4433 provides precise electronic overcurrent protection for dual channels rated at 3 A each. Operating directly within the standard EtherCAT terminal segment, this module dynamically monitors load currents, offering rapid electronic shutdown in the event of an overload or short circuit, thereby limiting system downtime. It features integrated status LEDs and physical push-buttons on the housing for immediate channel-level diagnostics and manual reset capability, while feeding complete diagnostic telemetry back to the controller via the E-bus interface.

Features

  • Dual-Channel Monitoring: Two independent 24 V DC distribution paths, limiting maximum current to 3 A per channel.
  • Hardware Redundancy: Integrated 4 A slow-blow fail-safe backup fuses provide hardware-level backup protection.
  • E-Bus Telemetry: Seamless configuration, current monitoring, and diagnostic reporting directly through TwinCAT.
  • Local Interactivity: Dedicated LED push-buttons on the terminal face allow for direct manual reset and instant physical status feedback.
  • High Packing Density: Compact 12 mm modular housing width minimizes DIN-rail footprint in control panels.

Applications

  • Sensor/Actuator Power Distribution: Safe current-limited supply routing for decentralized field sensors and valve terminals.
  • Control Cabinet Sub-Circuit Protection: Isolation of critical low-voltage hardware to prevent system-wide voltage collapses during single-point field faults.
  • EtherCAT Segment Protection: Protection of downstream auxiliary power contacts across I/O nodes.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model / Article Number EL9222-4433
Nominal Operating Voltage 24 V DC
Number of Channels 2
Rated Current 3 A per channel
Max. Input Supply Current 10 A
Current Consumption (E-bus) 80 mA typical
Electrical Isolation 500 V (E-bus to signal voltage)
Backup Fail-Safe Element 4 A slow-blow (T) / 4 A slow-blow (T)
Overvoltage Cut-off >= 32 V DC
Hold After Trip-Out >= 10 s
Advance Load Warning Threshold 90 percent of rated channel load
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Enclosure Protection Rating IP20
Housing Material Polycarbonate
Physical Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Weight 55 g
Shipping Weight (Calculated) 2.0 kg
Certifications and Approvals CE, cULus, cURus

Connections & Interface Terminal Guide

Terminal Contact Wiring Specifications & Signal Mapping
Solid Conductor Range 0.08 to 2.5 mm² (AWG 28 to 14) via screwdriver spring actuation
Stranded Conductor Range 0.08 to 2.5 mm² (AWG 28 to 14)
Conductor with Ferrule (f) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Depth 8 to 9 mm
Power Contact Rating Imax: 10 A (Output 1 utilizes internal power contact path)

Empirical Engineering Insights

Alternative Models & Compatibility

The EL9222-4433 is optimized for 3 A fixed current limits per channel. For variable current configurations, look to the adjustable EtherCAT terminals (such as the EL9224). When inserting this module into an existing I/O stack, ensure that your TwinCAT EtherCAT XML Device Description (ESI) files are updated to match the specific firmware revision. If replacing an older EL9222-0000, verify that your E-bus current budget can handle the 80 mA load of the EL9222-4433.

Application Pitfalls & Engineering Notes

The absolute maximum capacity of the power contact rail is 10 A. Continuous heavy loads across multiple downstream modules must be calculated to prevent overload of the power contacts. If your segment exceeds 10 A total, you must insert an EL9100 or EL9110 power feed terminal directly upstream to segment the power contacts and prevent local terminal overheating.

Commissioning & Wiring Tips

To avoid intermittent faults, adhere strictly to the 8 to 9 mm stripping length. Under-stripping causes insecure mechanical tension clamp engagement, while over-stripping risks exposing bare wire to adjacent, closely-spaced terminals. When commissioning from TwinCAT, remember to map the CoE (CanOverEtherCAT) objects to read historical trip data and clear fault states remotely.

Installation Guidelines

CRITICAL WARNING:

De-energize the entire segment and isolate all 24 V DC power feeds before installing or removing the overcurrent protection terminal. Failure to do so may damage the E-bus connection pins, disrupt network communications, or lead to accidental arc discharges across adjacent contacts.

1
Align the EL9222-4433 terminal with the 35 mm DIN rail (conforming to EN 60715) alongside the existing EtherCAT segment. Ensure the slot and key guides line up correctly.
2
Press the terminal firmly onto the DIN rail until you hear the locking latch snap into position, securing the E-bus connections.
3
Using a standard terminal screwdriver, actuate the spring-actuated clamp connections to insert conductors stripped to 8-9 mm. Re-verify the wire cross-section conforms to AWG 28-14 (solid/stranded) or AWG 26-16 (ferrule).
4
Apply 24 V DC control power, boot the TwinCAT system, and verify that the front status LEDs illuminate green, indicating normal channel conditions.
Loading product navigation…

What is the primary function of the LED buttons on this terminal?

The integrated LED buttons serve a dual purpose: they physically display channel status (overload, tripped, or normal) and allow for direct local manual channel resetting during troubleshooting or maintenance.

Does this module require a separate power feed terminal?

The module uses standard 24 V DC power contacts. If the total cumulative current of your EtherCAT segment's power contacts exceeds 10 A, an upstream feed module like the EL9100 must be integrated to isolate and protect the bus.

Can I configure custom trip currents for the channels?

No, the EL9222-4433 features preset, hardware-defined tripping curves configured for a maximum of 3 A per channel. For adjustable configurations, look to programmable alternatives like the EL9224.

What is the required hold time after an overcurrent trip before resetting?

To prevent immediate thermal stress, there is a built-in thermal cooldown lockout requiring at least 10 seconds after a channel switches off before a reset can be triggered.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...