Beckhoff EPP2008-0022 EtherCAT P Box 8-channel Digital Output Module

Beckhoff EPP2008-0022 EtherCAT P Box 8-channel Digital Output Module

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: EPP2008-0022

  • País de origem:Alemanha

  • Tipo de Produto: EtherCAT P Modules

  • Pagamento: T/T, Western Union

  • Peso: 500g

  • Dimensões: 180 x 120 x 80 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Direct field connection of decentralized actuators is managed reliably by the Beckhoff EPP2008-0022, an IP67-rated EtherCAT P Box engineered for high-performance automation networks. By integrating control signal data and power (both system voltage Us and auxiliary peripheral voltage Up) into a single, specialized cable, this module eliminates the need for external distribution enclosures. The unit features eight independent digital outputs delivering 24 V DC to handle ohmic, inductive, and lamp loads, making it ideal for severe industrial processing environments.

Features

  • One-Cable Automation: Combines high-speed EtherCAT communication and power supply over a single P-coded M8 connector interface.
  • High Channel Density: 8 digital outputs housed in a compact, ruggedized field module.
  • Individual Channel Protection: Every output channel is individually short-circuit proof with immediate overload detection.
  • Robust Load Compatibility: Capable of switching resistive (ohmic), inductive, and lamp loads up to 0.5 A per channel.
  • Environmental Resilience: Hermetically sealed IP65, IP66, and IP67 protective rating allows direct machine mounting without protective enclosures.

Applications

  • Decentralized robotics assembly cells and end-of-arm tooling.
  • Conveyor systems and high-speed material handling sortation networks.
  • Pneumatic valve manifold control and solenoid actuator switching.
  • Automotive assembly lines requiring direct tool-mounted IP67-rated I/O distribution.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Number EPP2008-0022
Communication Protocol EtherCAT
Bus Interface 2 x M8 socket, shielded, screw-type, P-coded
Number of Outputs 8 digital outputs
Output Connections M12 x 1, 5-pin, A-coded (1 output per M12 connector)
Nominal Output Voltage 24 V DC (-15 percent / +20 percent)
Max. Output Current 0.5 A per channel (individually short-circuit proof, total sum limit 3.0 A)
Short-Circuit Current Limit Max. 1.5 A
Switching Times Typical TON: 60 us, typical TOFF: 300 us
Current Consumption (Us) Typical 100 mA
Auxiliary Current (Up) Typical 20 mA + load current
Electrical Isolation 500 V
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Conformity Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals CE, UL
Unit Weight Approx. 250 g
Shipping Weight (Calculated) 2.0 kg
Package Dimensions (Calculated) 180 x 120 x 80 mm

Connections and Interfaces

Port / Connector Interface Type Pin Mapping & Assignment
EtherCAT P Input M8, female, 4-pin, P-coded Pin 1: Tx+ / Us+ | Pin 2: Rx+ / Up+ | Pin 3: Rx- / Up- | Pin 4: Tx- / Us-
EtherCAT P Output M8, male, 4-pin, P-coded Downstream line feed with data forwarding and Us/Up power loop-through
Channels 1 to 8 M12, 5-pin, A-coded Pin 1: Up (+24 V DC auxiliary output) | Pin 3: GND | Pin 4: Output signal | Pins 2 & 5: Functional Earth / Shield

Empirical Engineering Insights

Alternative Models & Compatibility

The EPP2008-0022 utilizes EtherCAT P technology, combining data and power. It is fundamentally different from standard EP2008 series boxes, which run on standard EtherCAT and require independent 24 V DC auxiliary power lines. Note that integration within your TwinCAT development environment requires TwinCAT 3.1 Build 4022 or higher. If migrating from older EP modules, verify that your network couplers or master terminals support EtherCAT P physical layers (e.g., EK1300 or EK1322).

Application Pitfalls & Engineering Notes

Because EtherCAT P supplies both the sensor/logic circuit (Us) and peripheral actuator loads (Up) over a single P-coded cable, cumulative current limits must be carefully planned. The absolute continuous current limit for the P-coded M8 bus connector is 3 A. Running eight high-power inductive loads at the full 0.5 A capacity will exceed the loop-through rating of downstream units, causing severe voltage drops and thermal stress on downstream boxes.

Commissioning & Wiring Tips

Always use fully shielded, industrial-grade M8 P-coded cabling to ensure electromagnetic immunity in noisy motor-drive environments. When terminating M12 ports, utilize a calibrated torque wrench to ensure tight sealing to 0.6 Nm; over-tightening or loose installation compromises the IP67 integrity and will lead to moisture ingress. Utilize TwinCAT's built-in EtherCAT P diagnostics window to monitor live voltage drops for both Us and Up power branches during full load operation.

Installation Guidelines

CRITICAL WARNING: De-energize all primary, auxiliary, and network power sources before initiating installation. Failure to disconnect system (Us) and peripheral (Up) power prior to wiring or module removal can result in hardware destruction or unexpected physical operation of associated field actuators.
1
Mount the EPP2008-0022 directly to the machine structure using M3 mounting bolts tightened to a maximum torque of 0.5 Nm. Ensure the mounting surface is flat to avoid structural strain on the housing.
2
Connect the incoming EtherCAT P M8 line to the "EtherCAT P In" port and verify the physical P-coding alignment key to avoid forcing the pins.
3
Route outgoing digital actuator lines using M12 cables. Plug unused M12 and M8 ports with genuine industrial sealing caps to guarantee the overall IP67 protection rating.
Loading product navigation…

What is the primary difference between Beckhoff EP2008 and EPP2008-0022?

The EPP2008-0022 uses EtherCAT P technology, combining communications and power (both Us and Up) on a single M8 cable. Standard EP2008 modules require separate power cables for communications and field IO power.

Can I mix standard EtherCAT and EtherCAT P modules on the same segment?

No, you cannot connect them directly on the same branch. You must use an EtherCAT P junction box, such as the EP9224-0037 or EK1310, to bridge standard EtherCAT networks to EtherCAT P segments.

What is the maximum total output current allowed for the EPP2008-0022?

While each of the 8 channels can switch up to 0.5 A, the total sum current across all outputs must not exceed 3.0 A due to physical terminal limits.

How does the short-circuit protection behave under overload conditions?

Each channel is individually protected. If a short-circuit occurs on a channel, it will limit the current to approximately 1.5 A and diagnostic status bits will flag the error state in your controller.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...