1 de 1

Beckhoff EPP3744-0041 EtherCAT P Box 4-Channel Pressure and 6-Channel Digital Input Module

Beckhoff EPP3744-0041 EtherCAT P Box 4-Channel Pressure and 6-Channel Digital Input Module

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: EPP3744-0041

  • País de origem:Alemanha

  • Tipo de Produto: EtherCAT P I/O Modules

  • Pagamento: T/T, Western Union

  • Peso: 500g

  • Dimensões: 150 x 60 x 40 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver informações completas

Integrating pneumatic diagnostics directly into the field level, the Beckhoff EPP3744-0041 EtherCAT P Box provides a decentralized interface for both digital signals and direct air pressure measurement. This rugged, IP67-rated module combines four relative pressure inputs, six digital inputs, and two digital outputs into a single compact housing, eliminating the need for protective control enclosures and reducing field wiring complexity.

Key Features

  • Unified Power and Data: EtherCAT P technology integrates high-speed communication and dual 24 V DC power supplies (Us for system/sensors and Up for actuators) into a single M8 P-coded connection.
  • Direct Pneumatic Interface: Four integrated pressure sensors with 6 mm push-in fittings for direct machine-mount air pressure monitoring.
  • Flexible Digital I/O: Six digital inputs (EN 61131-2, Type 1/3) and two short-circuit proof 0.5 A digital outputs handle localized sensor and actuator connections.
  • Distributed Clocks: High-precision synchronization support for time-critical industrial automation processes.
  • Environmental Resilience: Fully encapsulated IP65/66/67 housing designed to withstand extreme vibration, shock, and wet industrial environments.

Industrial Applications

  • Pneumatic System Diagnostics: Real-time pressure drop monitoring and leak detection in localized valve manifolds.
  • Robotic End-of-Arm Tooling (EOAT): Lightweight, decentralized I/O and vacuum/pressure sensing directly on robotic arms.
  • Packaging and Assembly Lines: Distributed sensor collection and pneumatic cylinder control without localized terminal boxes.
  • Material Handling: Vacuum gripper monitoring and localized conveyor control in sorting facilities.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation GmbH & Co. KG
Model / Article Number EPP3744-0041
Protocol EtherCAT P
Bus Interface 2 x M8 socket, shielded, screw type, P-coded
Number of Inputs 4 x pressure inputs, 6 x digital inputs
Number of Outputs 2 x digital outputs
Connection Method (I/O) Digital: 4-pin M8; Pressure: 6 mm push-in fitting
Measuring Range -1 to 1 bar (-15 to 15 psi) / 0 to 1 bar (0 to 15 psi) relative pressure
Resolution 1 mbar per digit
Measurement Uncertainty 3 percent of full scale
Conversion Time approximately 3.5 ms
Nominal Voltage 24 V DC (-15 percent / +20 percent)
Current Consumption (Us) 100 mA typical
Max. Output Current 0.5 A per channel (short-circuit proof)
Electrical Isolation 500 V
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Approvals CE, UL
Country of Origin Germany
Shipping Weight (Calculated) 0.35 kg (Net: 0.15 kg)
Package Dimensions (Calculated) 150 x 60 x 40 mm

Connections and Interfaces

Connector / Terminal Pin / Connection Function / Circuit Assignment
EtherCAT P (M8 P-coded) Pin 1 Us+ (24 V DC system and sensor supply)
Pin 2 Up+ (24 V DC peripheral voltage for actuators)
Pin 3 Us- (GND for system and sensor supply)
Pin 4 Up- (GND for peripheral voltage)
Digital I/O (M8 4-pin) Pin 1 +24 V DC sensor supply (derived from Us)
Pin 2 Input / Output Channel B
Pin 3 GND
Pin 4 Input / Output Channel A
Pneumatic Ports Ports 1 to 4 6 mm push-in fittings for relative air pressure measurement

Empirical Engineering Insights

Alternative Models & Compatibility

The EPP3744-0041 is an EtherCAT P device and must not be connected to standard EtherCAT (EP series) ports without an intermediate junction or injector module (such as the EP9224-0002). Standard EtherCAT uses D-coded M8 connectors, whereas EtherCAT P utilizes P-coded M8 connectors to prevent accidental cross-wiring of combined power and data lines.

Application Pitfalls & Engineering Notes

When deploying the module in high-humidity environments, ensure that the compressed air supplied to the 6 mm pneumatic fittings is thoroughly dried and filtered. Liquid condensation or oil mist entering the internal silicon pressure sensors will cause calibration drift, measurement offsets, or permanent sensor element failure.

Commissioning & Wiring Tips

Always calculate the total current draw of the EtherCAT P segment in TwinCAT 3 before physical commissioning. The combined current for Us and Up must not exceed 3 A per branch. If voltage drops below 20.4 V DC at the end of a daisy chain, install an EP9224 power feed-in box to boost the supply.

Installation Guidelines

CRITICAL WARNING

Disconnect all electrical power sources (Us and Up) and completely depressurize the pneumatic lines before mounting, wiring, or servicing this module. Failure to do so can result in equipment damage, unexpected actuator movement, or physical injury from high-velocity pneumatic tubing ejection.

1

Mount the module to a flat, vibration-resistant machine surface using two M3 screws. Torque to 0.8 Nm.

2

Insert clean, square-cut 6 mm pneumatic tubing into the push-in fittings until it bottoms out securely.

3

Connect the M8 P-coded EtherCAT P cables. Tighten the screw connections to 0.4 Nm to guarantee the IP67 environmental seal.

4

Connect digital sensors and actuators to the M8 I/O ports using shielded cables to minimize electromagnetic interference.

Loading product navigation…

What is the difference between EPP3744-0041 and EP3744-0041?

The EPP3744-0041 utilizes EtherCAT P, which integrates both communication and 24 V DC power (Us and Up) into a single M8 P-coded connector. The EP3744-0041 uses standard EtherCAT with separate power and data connections.

How do I prevent moisture damage to the pressure sensors?

Ensure the compressed air supply is dry and filtered. Use upstream coalescing filters and water separators to prevent condensation from entering the 6 mm pneumatic fittings and damaging the internal silicon sensors.

What is the maximum current capacity for the digital outputs?

Each digital output channel supports a maximum current of 0.5 A. The outputs are individually short-circuit proof to protect the module from field wiring faults.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...