1 de 1

BECKHOFF IL2300-B518 Fieldbus Box CANopen Coupler Box

BECKHOFF IL2300-B518 Fieldbus Box CANopen Coupler Box

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: IL2300-B518

  • País de origem:Alemanha

  • Tipo de Produto: Fieldbus Coupler Boxes

  • Pagamento: T/T, Western Union

  • Peso: 500g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

The Beckhoff IL2300-B518 is a high-performance, decentralized Fieldbus Box designed to establish direct communication between a CANopen network and extension IP67 I/O modules. Engineered for rugged industrial environments, this coupler box eliminates the need for protective control cabinets by offering a fully sealed housing. It supports automatic baud rate detection and efficiently manages decentralized digital and analog signals. The integrated T-connector design simplifies network looping and minimizes cabling complexity on the factory floor.

Features

  • High-Capacity Expansion: Connects up to 120 extension modules, managing up to 128 bytes of input and 128 bytes of output data.
  • Robust Signal Handling: Directs up to 960 digital inputs/outputs and up to 60 analog inputs/outputs.
  • Advanced CANopen Support: Built-in support for up to 16 send and 16 receive Process Data Objects (PDOs), node guarding, life guarding, emergency objects, variable mapping, and store/restore parameters.
  • Flexible Configuration: Easily configurable via the Beckhoff KS2000 software suite or directly through the controller using Service Data Objects (SDOs).
  • Industrial-Grade Housing: Sealed structure certified to IP65/66/67 ratings for complete protection against dust, water jets, and temporary immersion.

Applications

  • Automated assembly lines and material handling systems.
  • Machine tool manufacturing and decentralized robotics controls.
  • Harsh wet-room applications including food and beverage processing.
  • Automotive manufacturing plants and heavy machinery.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model / Part Number IL2300-B518
Fieldbus Interface CANopen
Data Transfer Rates 10 kbaud to 1 Mbaud (automatic detection)
Bus Connection 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) (integrated T-connector)
Control Voltage 24 V DC (-15% / +20%)
Load Voltage Determined by connected I/O type
Power Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Current Consumption 45 mA + sensor current (max. 0.5 A)
Electrical Isolation 500 V (control voltage / fieldbus)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Compatibility Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Connector Type Pin Count Function
M12 Plug (Inlet) 5-pin CANopen fieldbus input
M12 Socket (Outlet) 5-pin CANopen fieldbus downstream loop
M8 Male Socket 4-pin 24 V DC power feed input
M8 Female Socket 4-pin 24 V DC downstream power connection

Installation Guidelines

  • Mounting: Mount in any physical orientation using the integrated mounting holes. Ensure the surface is flat to prevent mechanical stress on the housing.
  • Grounding: Ensure the mounting surface or grounding connection is properly bonded to functional earth to maximize EMC performance and shield integrity.
  • IP Rating Maintenance: Securely tighten all unused M12 and M8 ports with protective caps to maintain the IP65/66/67 rating.
  • Cabling: Keep signal cables and power cables separated when routing to avoid electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the maximum number of I/O modules supported by the Beckhoff IL2300-B518?

The IL2300-B518 supports up to 120 extension modules, handling a maximum of 128 bytes of input data and 128 bytes of output data.

What fieldbus protocol does this coupler box utilize?

This module operates on the CANopen protocol and features automatic baud rate detection from 10 kbaud up to 1 Mbaud.

Does this module require an external enclosure or cabinet?

No, with an IP65/66/67 protection rating, the IL2300-B518 is designed for direct mounting on machines and in harsh environments without an extra control cabinet.

What are the power requirements for the IL2300-B518?

The module requires a 24 V DC control voltage (-15% / +20%) supplied via a 4-pin M8 connector.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...