Designed for direct, machine-mount distributed deployment, the Beckhoff IP2002-B518 coordinates high-density localized outputs without the footprint or cost of protective control enclosures. This decentralized fieldbus box integrates 8 digital outputs operating at 24 V DC, utilizing CANopen protocol communications to optimize real-time control architectures. With integrated M12 T-junction connectors, this device enables clean line-topology bus configurations directly on physical machine frames. Wrapped in a ruggedized polyamide housing, it delivers reliable IP67 protection against moisture, dust, and continuous industrial vibrations.

Features

  • 8 Digital Outputs: Delivers up to 0.5 A per channel, fully compatible with resistive, inductive, and lamp load setups.
  • Integrated T-Connector: Built-in M12 5-pin male and female connectors enable straightforward physical looping of the CANopen bus.
  • Short-Circuit Diagnostics: Individual output channels feature electronic short-circuit protection to insulate localized faults.
  • Flexible Power Distribution: Dedicated M8 connections isolate control logic power (Us) from physical load power (Up).
  • Aggressive Environmental Rating: Rated for IP65/66/67 operation, securing signal paths in high-spray washdown zones.

Applications

  • Pneumatic Valve Block Control: Direct switching of manifold pilot valves on moving gantry assemblies.
  • Material Handling Conveyors: Localized routing of sorting diverters, stop gates, and indicator lights.
  • Automotive Assembly Tooling: Robotic end-effector output distribution where control enclosure space is non-existent.
  • Packaging and Bottling Machinery: Multi-station actuator triggering in high-moisture production zones.

Technical Specifications Table

Parameter Value / Specification
Manufacturer Beckhoff
Model Number IP2002-B518
Module Type 8-Channel Digital Output Fieldbus Box
Protocol / Interface CANopen (16 Tx / 16 Rx PDOs supported)
Supported Baud Rates 10 kbaud to 1 Mbaud (automatic detection)
Number of Outputs 8 (single-wire connection)
Nominal Output Voltage 24 V DC (-15 % / +20 %)
Max. Output Current 0.5 A per channel (individually short-circuit proof)
Electrical Isolation 500 V (Control voltage to fieldbus)
Control Voltage Supply (Us) 24 V DC, typical 45 mA current consumption
Fieldbus Connection 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) (Integrated T-Connector)
Power Supply Feed 1 x M8 male (4-pin); Downstream loop: 1 x M8 female (4-pin)
Housing Material Polyamide PA6 (XXL housing)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Class IP65 / IP66 / IP67 (conforms to EN 60529)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector / Interface Pin Number Signal Assignment
CANopen Fieldbus (M12) Pin 1 CAN_SHLD (Shield)
Pin 2 V+ (Optional External Power)
Pin 3 CAN_GND (Ground)
Pin 4 CAN_H (Signal High)
Pin 5 CAN_L (Signal Low)
Power Supply Feed (M8) Pin 1 Us +24 V DC (Control Voltage for Electronics)
Pin 2 Up +24 V DC (Load Voltage for Digital Outputs)
Pin 3 GNDs (Control Ground)
Pin 4 GNDp (Load Ground)

Empirical Engineering Insights

Alternative Models & Compatibility

The B518 variant serves as an drop-in optimization over legacy B510 fieldbus boxes. Because the IP2002-B518 integrates the T-connector directly within its molded housing, it completely replaces the requirement for external "Z1001" network splitter adapters, decreasing field cabling clutter and potential points of ingress failure.

Application Pitfalls & Engineering Notes

While each individual channel features short-circuit current protection peaking at approximately 1.5 A under fault conditions, the cumulative load across all 8 output channels must not exceed the maximum current rating of the feeding M8 terminal (typically capped at 4 A total across Up). Ensure appropriate current-budget configurations are calculated for simultaneously active inductive loads.

Commissioning & Wiring Tips

To access the decimal rotary node-ID configuration switches, remove the protective cover plate using a small flat screwdriver. Ensure this plate is re-seated with its sealing gasket completely flush to preserve the IP67 integrity. Additionally, note that this module does not integrate internal CAN termination resistors; a physical M12 termination plug must be added at the terminal physical drop-point of the network.

Installation Guidelines

CRITICAL WARNING: Ensure all power distribution lines (Us and Up) are fully de-energized prior to connecting or disconnecting any M8 or M12 cables. Connecting active power lines to IP-series modules can result in contact-arc damage and compromise internal diagnostic logic.
1
Mechanical Mounting: Mount the module directly onto a flat machinery support structure using the two 3.5 mm diameter fixing points using M3 screws. Ensure no torsional stress is applied to the PA6 housing.
2
Configure Node ID: Unscrew the protective cover. Using a rotary switch tool, set the correct CANopen Node ID. Verify the baud rate setting is configured correctly (defaulting to auto-detection). Re-seal the cover.
3
Bus & I/O Connections: Connect the M12 fieldbus lines to the integrated T-connector ports. Tighten the knurled metal collars hand-tight (0.6 Nm torque recommended) to guarantee environmental protection.
4
Power Integration: Hook up the incoming 4-pin M8 feed. If multiple boxes are in line, loop from the downstream M8 female connector to the subsequent device.
Loading product navigation…

What is the function of the integrated T-connector on the IP2002-B518?

The integrated T-connector consists of an M12 plug and an M12 socket, allowing the CANopen fieldbus cable to loop through the module directly. This eliminates the need for separate external T-splitters on the line.

Are the control and load voltages electrically isolated?

Yes, there is 500 V electrical isolation between the control voltage electronics (Us) and the CANopen fieldbus network, reducing the risk of ground loops and signal interference.

How do you set the CANopen node address on this module?

The address is set manually using two decimal rotary switches located under a protective screw-retained cover plate on the front of the polyamide housing.

What happens if a single digital output channel is short-circuited?

Each of the 8 digital outputs is individually short-circuit proof. If a fault occurs, the module limits the current to typically 1.5 A and isolates the fault locally without shutting down the entire block.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...