Description

Designed for direct decentralised installation on machinery without requiring protective control cabinets, the Beckhoff IP2041-B318 digital output module interfaces binary control signals with the PROFIBUS DP network. This Fieldbus Box accommodates eight digital outputs, each handling high load currents up to 2 A (with a total combined module current capacity of 12 A). The module uses space-saving M8 screw-type connectors for secure I/O coupling, and features an integrated B-coded M12 T-connector to simplify PROFIBUS loop-through cabling.

The IP2041-B318 supports DP-V1 extensions and can be configured through the KS2000 software suite or directly via the master controller. Its robust polyamide construction is sealed to IP67 standards, making it highly resilient against moisture, dust, and mechanical stress in demanding production environments.

Features

  • Eight independent 24 V DC digital outputs rated for resistive, inductive, and lamp loads.
  • Individually short-circuit proof outputs with a nominal channel capacity of 2 A.
  • High total power handling, supporting up to 12 A total current across output groups.
  • Integrated M12 B-coded T-connector (1x plug, 1x socket) for direct PROFIBUS network distribution.
  • Automatic fieldbus baud rate detection up to 12 Mbaud.
  • IP65, IP66, and IP67 dust and moisture ingress protection.
  • Configuration accessibility via the KS2000 commissioning tool or the host controller.

Applications

  • Machine tool and processing center integration
  • Conveyor and material handling automation
  • Packaging and bottling plants
  • Assembly lines and robotics platforms

Technical Specifications

Manufacturer Beckhoff
Part Number / Model IP2041-B318
Protocol / Interface PROFIBUS DP
Number of Outputs 8 digital outputs
Nominal Output Voltage 24 V DC (-15% / +20%)
Max. Output Current 2 A per channel (total max. 12 A; Channel 0 to 3: sum 4 A, Channel 4 to 5: sum 4 A, Channel 6 to 7: sum 4 A)
Short-Circuit Current typical 4 A
Data Transfer Rates Automatic detection up to 12 Mbaud
Bus Connection 1 x M12 socket (5-pin), 1 x M12 plug (5-pin), B-coded, integrated T-connector
Power Feed Connections 2 x M8 male socket, 4-pin (no downstream connection)
Box Supply Current 85 mA + sensor current consumption (max. 0.5 A)
Auxiliary Power Current typical 50 mA per channel
Housing Type XXL housing
Housing Material PA6 (polyamide)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP65, IP66, IP67 (conforms to EN 60529)

Connections and Interfaces

Interface Type Connector Style Function / Pin Assignment
PROFIBUS DP M12 (1x socket, 1x plug), B-coded Incoming and outgoing bus loop (integrated T-connector)
Outputs (0 to 7) M8, screw-type Actuator / output channel connections
Power Supply Feed 2x M8 male socket, 4-pin Control voltage and load voltage inputs

Installation Guidelines

  • Mount the module directly to the machinery frame using the two 3.5 mm diameter fixing holes intended for M3 screws.
  • Ensure all unused M8 and M12 ports are sealed with approved IP67-rated protective caps to maintain environmental sealing.
  • Route communication cables separately from high-voltage power lines to minimize potential electromagnetic interference.
  • Ensure grounding connection is properly made to the machine body to guarantee EMC compliance and system stability.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the maximum output current limit of the Beckhoff IP2041-B318?

Each digital output channel can handle up to 2 A. However, the total module current must not exceed 12 A, with a limit of 4 A per group (Channels 0-3, 4-5, and 6-7).

Does the IP2041-B318 require an external T-connector for PROFIBUS?

No, it features an integrated B-coded M12 T-connector with one socket and one plug, allowing you to chain the fieldbus line directly through the module.

What is the environmental ingress protection level of this unit?

The module is rated IP65, IP66, and IP67 when all ports are mated with correct IP67 connectors or sealed with protective caps, making it suitable for direct machine mounting.

Can the IP2041-B318 be configured via software?

Yes, configuration is supported via the Beckhoff KS2000 software tool or directly through the PROFIBUS controller utilizing DP-V1 extensions.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...