Integrating decentralized field signals directly into PROFIBUS DP architectures, the Beckhoff IP3112-B318 functions as a highly robust Fieldbus Box designed for harsh operational environments. This module enables direct connection of physical industrial sensors and actuators without the need for an additional protective control cabinet. Operating seamlessly on PROFIBUS systems, it supports dynamic configuration options and handles data rates up to 12 Mbaud with automatic detection. The fully sealed housing delivers excellent dust and water ingress protection, making it suitable for direct machine mounting in heavy manufacturing environments.

Features

  • Direct integration with PROFIBUS DP networks supporting DP-V1 extensions.
  • Automatic detection of communication transmission rates up to 12 Mbaud.
  • Standardized B-coded M12 physical bus interface with integrated T-connector.
  • Rugged housing rated for IP65, IP66, and IP67 protection classes.
  • M8 power supply connectors supporting simple daisy-chaining to downstream modules.
  • Flexible configuration possibilities via KS2000 software or directly through the main controller.

Applications

  • Cabinet-free automation architectures in automotive production lines.
  • Material handling, sorting, and conveyor systems requiring localized physical inputs.
  • Heavy industrial plants subject to high vibration, moisture, and fine particulates.
  • Process industries requiring decentralized data collection over extended distances.

Technical Specifications

Specification Parameter Value / Detail
Manufacturer Beckhoff
Model Number / SKU IP3112-B318
Protocol / Interface PROFIBUS DP (with DP-V1 extensions support)
Data Transfer Rates Up to 12 Mbaud (automatic detection)
Control Voltage Supply 24 V DC (-15% / +20%)
Box Current Consumption 85 mA + sensor current (maximum 0.5 A)
Electrical Isolation Control voltage to fieldbus: No; Control voltage to I/O: according to I/O type
Operating Temperature 0 to +55 degC (Celsius)
Storage Temperature -25 to +85 degC (Celsius)
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals CE, UL
Country of Origin Germany
Shipping Weight (Calculated) 2.00 kg
Package Dimensions (Calculated) 126 x 30 x 27 mm

Connections and Interfaces

Connection Type Hardware Interface Pin Allocation / Purpose
Fieldbus Input 1 x M12 plug (B-coded) 5-pin PROFIBUS DP connection with integrated tee-connector
Fieldbus Output 1 x M12 socket (B-coded) 5-pin downstream PROFIBUS DP connection
Power Feed 1 x M8 male socket 4-pin control voltage input (24 V DC)
Power Downstream 1 x M8 female socket 4-pin control voltage pass-through for downstream modules

Alternative Models & Compatibility

The IP3112-B318 belongs to the Beckhoff Fieldbus Box family. It is physically and electrically drop-in compatible with standard PROFIBUS DP networks utilizing B-coded M12 cabling. Parameters can be assigned using the standard GSD configuration file provided by the manufacturer or the specialized KS2000 configuration tool interface. Ensure firmware versions in your master controller support standard DP-V1 acyclic read/write data records for diagnostic access.

Application Pitfalls & Engineering Notes

When daisy-chaining multiple IP-series modules using the M8 power distribution interfaces, calculate total cumulative current draw meticulously. The M8 connectors are rated for a maximum total feed current of 4 A. Exceeding this thermal threshold will cause permanent damage to the internal power plane. To prevent voltage drops across complex topologies, execute a fresh power feed loop injection whenever the maximum sensor load approaches 4 A.

Commissioning & Wiring Tips

Always utilize shielded twisted-pair copper cabling specifically rated for PROFIBUS DP transmission (typically 2 x 0.25 mm2 with a characteristic impedance of 150 ohms). To guarantee structural integrity of the IP67 seal rating, tighten all M8/M12 connectors using a calibrated torque wrench set to exactly 0.4 Nm for M8 and 0.6 Nm for M12. Unused connector sockets must be capped using certified industrial sealing plugs.

Installation Guidelines

CRITICAL WARNING

Do not perform hot-plugging or wiring modifications while the 24 V DC power network is live. Ensure all power supplies are de-energized and locked out before initiating the mounting or cable mating process. Improper grounding of the shield line can lead to communication degradation and physical hardware damage due to ground loops.

1

Mount the Fieldbus Box directly to the machine structure using the integrated mounting flanges. Ensure the mounting plane is flat to avoid structural tension on the housing body.

2

Establish the physical PROFIBUS connection using the B-coded M12 connectors, verifying that the integrated T-connector is correctly seated for continuous line topology.

3

Connect the 24 V DC control voltage line to the M8 feed connector. Ensure correct polarity to prevent reverse bias currents.

4

Secure all unused ports with screw-on IP67 caps. Turn on power, configure the device address using the master controller software, and perform logical validation.

Loading product navigation…

Can I configure the IP3112-B318 fieldbus box without the KS2000 software interface?

Yes, configuration parameters and operating modes can be defined directly through the master controller using GSD configuration file integration, or acyclically via DP-V1 mechanisms.

What happens if I exceed the 4 A feed current limit on the M8 power distribution loops?

Exceeding 4 A will cause overheating and thermal stress on the internal power routing tracks of the fieldbus box, leading to hardware failure. Introduce external power feed injections to keep lines below 4 A.

Is the PROFIBUS line terminated internally in the IP3112-B318 module?

No, there is no integrated termination resistor inside the module. If the IP3112-B318 is located at the physical end of the PROFIBUS segment, you must install an external M12 termination resistor.

Does this module support both control voltage and load voltage isolation?

Electrical isolation between control voltage and fieldbus is not present, while isolation between control voltage and inputs or outputs depends on the specific hardware I/O sub-type of the box.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...