Beckhoff IP5109-B520 Fieldbus Box

Beckhoff IP5109-B520 Fieldbus Box

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: IP5109-B520

  • País de origem:Alemanha

  • Tipo de Produto: Fieldbus Boxes

  • Pagamento: T/T, Western Union

  • Peso: 2000g

  • Dimensões: 2 x 2 x 0.25 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed for decentralized automation architecture, the Beckhoff IP5109-B520 Fieldbus Box establishes reliable distributed I/O connection in harsh manufacturing environments. Operating directly on DeviceNet networks, this robust module eliminates the need for protective control cabinets by providing high ingress protection against dust and liquid exposure. The module features integrated intelligence to detect network transmission speeds dynamically and offers extensive diagnostic functions to minimize plant downtime.

The IP5109-B520 integrates seamless physical layer interfaces using industry-standard M12 and M8 connections. It facilitates flexible communication types, including bit strobe, polling, cyclic, and change-of-state (COS) messaging, ensuring efficient data distribution to high-level controllers. System engineers can configure the module parameters easily through the Beckhoff KS2000 software suite or directly via explicit messaging from the master controller.

Features

  • Cabinet-Free Installation: Rugged design allows direct machine mounting, optimizing wiring paths and reducing installation footprint.
  • Automatic Baud Rate Detection: Automatically senses and adapts to communication speeds up to 500 kbaud.
  • Advanced Diagnostics: Comprehensive diagnostic LEDs provide local visibility into bus status, supply errors, and operational performance.
  • Flexible Communication Protocols: Supports a variety of DeviceNet I/O communication configurations, including polling, bit strobe, cyclic, and change of state.
  • Robust Power Isolation: Provides 500 V electrical isolation between control voltage and fieldbus components.

Applications

  • Automotive assembly and robotic welding lines
  • Material handling and conveyor sortation systems
  • Machine tool and manufacturing line integration
  • Heavy industrial packaging equipment
  • Water and wastewater treatment installations

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model IP5109-B520
Fieldbus Protocol DeviceNet
Data Transfer Rates Automatic detection up to 500 kbaud
Bus Interface Connection 1 x M12 plug, 5-pin
Transmission Medium Shielded copper cable with power supply (typically 2 x 2 x 0.25 mm²)
Control Voltage Power Supply 24 V DC (-15% / +20%)
Power Connection (Feed) 1 x M8 male connector, 4-pin
Power Connection (Downstream) 1 x M8 female connector, 4-pin
Internal Box Supply Current 45 mA + sensor consumption (maximum 0.5 A total)
Electrical Isolation 500 V (control voltage / fieldbus)
Max Station Distance 500 m / 250 m / 100 m (dependent on baud rate and cable type)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Class IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals CE, UL
Shipping Weight 2.0 kg

Connections and Interfaces

Connector / Pin Function Description
M12 Bus Pin 1 Shield (drain wire)
M12 Bus Pin 2 V+ (DeviceNet power supply)
M12 Bus Pin 3 V- (DeviceNet power supply reference)
M12 Bus Pin 4 CAN_H
M12 Bus Pin 5 CAN_L
M8 Power Supply Feed Pin 1 Control Voltage +24 V DC (Us)
M8 Power Supply Feed Pin 2 Load Voltage +24 V DC (Up)
M8 Power Supply Feed Pin 3 GNDs (Control Voltage reference)
M8 Power Supply Feed Pin 4 GNDp (Load Voltage reference)

Installation Guidelines

  • Mounting: Attach the box securely using the integrated mounting flanges on a flat, vibration-free surface. Direct metal contact assists with heat dissipation and structural stability.
  • Grounding: Ensure a low-resistance RF grounding connection to the machine chassis via the metallic mounting surfaces or dedicated grounding tabs.
  • Cabling Shielding: Use pre-assembled, shielded DeviceNet cabling to prevent electromagnetic interference from surrounding industrial equipment.
  • Connector Sealing: Tighten all M12 and M8 connectors to their specified torque limits. Cover any unused female sockets with IP67-rated protective caps to maintain the integrity of the enclosure seal.

What fieldbus protocol does the Beckhoff IP5109-B520 use?

The IP5109-B520 operates on the DeviceNet industrial protocol.

How is the communication speed configured on this module?

The module features automatic baud rate detection, allowing it to self-configure on the network up to a maximum transmission speed of 500 kbaud.

What ingress protection rating does this Fieldbus Box offer?

The IP5109-B520 is rated at IP65, IP66, and IP67, protecting internal electronics from heavy dust, water jets, and temporary immersion.

Which software tool is used to parameterize the Beckhoff IP5109-B520?

Configuration can be executed through the Beckhoff KS2000 software interface or directly via the network master utilizing explicit messaging protocols.

What are the power requirements for this device?

The module utilizes a 24 V DC control voltage (with a tolerance range of -15% to +20%) connected via a 4-pin M8 interface.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Transformaram a Mineração Subterrânea

Desde compressores CC acionados por corda até carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como...