Beckhoff KL4022 Bus Terminal 2-Channel Analog Output Module

Beckhoff KL4022 Bus Terminal 2-Channel Analog Output Module

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: KL4022

  • País de origem:Alemanha

  • Tipo de Produto: Analog Output Modules

  • Pagamento: T/T, Western Union

  • Peso: 1000g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed for integration into standard K-bus networks, the Beckhoff KL4022 enables high-precision processing of current loop control signals. This terminal converts 12-bit digital values from the automation controller into isolated analog current outputs within the standard 4 to 20 mA range. Its single-ended topology, compact housing, and low conversion latency make it highly suitable for demanding industrial actuator control, valve positioning, and motor drive setpoint configuration.

Features

  • Dual-channel analog output configuration utilizing single-ended common ground architecture.
  • Robust 12-bit digital-to-analog conversion delivering dependable loop precision.
  • High-integrity electrical isolation of 500 V between the internal K-bus and field signals.
  • Rapid internal conversion sequence with a typical processing time of 1.5 milliseconds.
  • Efficient power distribution leveraging integrated 24 V DC power contacts on the backplane.

Applications

  • Electro-pneumatic and electro-hydraulic proportional valve positioners.
  • Frequency inverter and variable speed drive (VSD) speed references.
  • Distributed SCADA and process control instrumentation interfaces.
  • Industrial boiler and heating element loop controller feedback.

Technical Specifications

Parameter Value / Rating
Manufacturer Beckhoff Automation
Model Number KL4022
Signal Range 4 to 20 mA
Number of Channels 2
Resolution 12-bit
Load Impedance Less than 500 Ohm
Conversion Time approx. 1.5 ms
Output Error Less than +/- 0.1% (relative to full-scale value)
Power Supply 24 V DC via power contacts (or 15 V DC via KL9515 supply terminal)
K-Bus Current Consumption typ. 75 mA
Electrical Isolation 500 V (K-bus / signal voltage)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Country of Origin Germany
Weight approx. 80 g
Shipping Weight (Calculated) 0.25 kg

Connections and Interfaces

Terminal Point Signal Assignment Description
1 OUT 1 Analog Output Channel 1 (+)
5 0V (1) Analog Output Channel 1 ground (-)
2 OUT 2 Analog Output Channel 2 (+)
6 0V (2) Analog Output Channel 2 ground (-)
3 +24 V Power Contact Connection (+24 V DC)
7 0 V Power Contact Connection (0 V DC)
4 Shield Shield contact point (connected to DIN rail)
8 Shield Shield contact point (connected to DIN rail)

Empirical Engineering Insights

Alternative Models & Compatibility

The KL4022 utilizes Beckhoff's legacy K-bus backplane communication system. If transitioning to an EtherCAT infrastructure, the direct equivalent is the EL4022. Note that EL-series terminals utilize the E-bus and cannot reside on standard KL-series couplers (e.g., BK9000, BK3120) without active E-bus/K-bus converter couplers.

Application Pitfalls & Engineering Notes

Since the KL4022 is a single-ended terminal sharing a common internal ground loop, noise injected into the 0 V signal reference on one loop can cause cross-talk or offset drift on the secondary channel. For field installations with significant ground potential differences, isolated signal conditioning barriers must be installed between the KL4022 and the end-actuator to prevent loop degradation.

Commissioning & Wiring Tips

Ensure that shielding is correctly terminated. Terminal points 4 and 8 are connected to the mounting rail. To guarantee sufficient noise rejection, the standard 35 mm DIN rail must be connected to the central control cabinet ground with low-impedance copper braided strap. Ensure K-bus power contacts are adequately populated with 24 V DC; voltage drops below 18 V DC will cause conversion errors or terminal fault signals within TwinCAT.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Isolate and lock out all power supplies to the system before inserting or removing K-bus components. Modifying the physical configuration or terminal assembly while the power is active can induce voltage spikes, resulting in damage to the internal bus driver circuitry or physical terminal contacts.

1

Mount the terminal onto the 35 mm DIN rail (EN 60715) by sliding the terminal's rear slot onto the rail guide until the locking tab audibly clicks.

2

Align the terminal laterally with the adjacent Bus Terminal block to engage the tongue-and-groove joint and establish continuous electrical contact via the side-mounted gold contacts.

3

Insert field connection cables into the cage-clamp connectors using an appropriate industrial screwdriver. Release the mechanism to secure wire connection.

4

Connect the analog loop shielding directly to contacts 4 or 8 to guarantee direct path grounding through the DIN rail structure.

Loading product navigation…

What is the key difference between the KL4022 and EL4022 modules?

The KL4022 operates on the K-bus backplane protocol for classic bus couplers, whereas the EL4022 communicates via E-bus for EtherCAT networks. They cannot be placed on the same terminal strip without a dedicated converter terminal.

Does this terminal require an external loop power supply for the current signal?

The KL4022 extracts its power from the integrated 24 V DC power contacts. If the power Contacts are not energized, or if isolation is required, you must insert a power supply terminal like the KL9100 or KL9200 immediately to its left.

How is the 12-bit resolution represented inside the controller software?

The 12-bit value is loaded into a 16-bit register as a left-aligned integer. The remaining 4 least-significant bits are ignored by the internal digital-to-analog converter.

Are the two output channels of the KL4022 electrically isolated from each other?

No, both channels share a common internal ground reference (0 V) and are single-ended. However, they are both electrically isolated up to 500 V from the K-bus logic circuitry.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...