The Bently Nevada 140482-01 is a Prox/Velom I/O module with external terminations designed for signal interfacing between transducers and the 3500/42M Proximitor Seismic Monitor or 3500/72M Recip Rod Position Monitor. The module routes input signals from Proximitor, accelerometer, Velomitor, or HTVS transducers located in the field through the rear slot of a 3500 system rack directly into the main monitor board. It conditions incoming signals and delivers power supply outputs while maintaining signal integrity for 4-channel vibration and position monitoring operations.

Features

  • Accepts inputs from Proximitor, accelerometer, Velomitor, or HTVS transducers
  • External termination interface design for off-rack field wiring connection
  • Supports multi-channel signal routing to the 3500/42M and 3500/72M monitor main boards
  • Occupies 1 full-height rear slot in the 3500 system rack

Applications

  • Machinery protection and condition monitoring
  • Hydro-turbines, gas turbines, and steam turbines
  • Reciprocating compressor rod position and drop monitoring
  • Industrial pumps, fans, and motor assemblies

Ordering Information

Part / Option Description
140482-01 Prox/Velom I/O Module with External Terminations
125808-08 Proximitor / Velomitor External Termination Block (Euro Style Connectors)
128015-08 Proximitor / Velomitor External Termination Block (Terminal Strip Connectors)
129525-AAAA-BB 3500 Transducer XDCR signal to External Termination Block Cable
00561941 3500/42M Prox/Velom I/O Module 10-pin connector shunt

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (a Baker Hughes Company)
Model 140482-01
Module Type Prox/Velom I/O Module with External Terminations
Compatible Transducers Prox/Accel, Velomitor, HTVS
Supply Parameters (Prox/Accel) U = 23.9 V, I = 45.5 mA, P = 1.09 W
Supply Parameters (Velomitor) U = 23.9 V, I = 45.5 mA, P = 1.09 W
Rack Space Requirement 1 full-height rear slot
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Humidity 95%, noncondensing
Dimensions (H x W x D) 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Weight 0.20 kg (0.44 lb)

Installation Guidelines

  • Install the module into 1 full-height rear slot corresponding to the associated front monitor module in the 3500 rack.
  • Connect the external termination block to the rear module using the designated 129525 external termination cable.
  • Ensure proper field wiring connection on the external termination block with supported transducer types.
  • Do not attempt to use external termination blocks with internal termination I/O modules.

Compliance and Certifications

Category Standard / Certification
EMC EN 61000-6-2, EN 61000-6-4 (Directive 2014/30/EU)
Electrical Safety EN 61010-1 (Directive 2014/35/EU)
RoHS Directive 2011/65/EU; China RoHS EFUP 15 years (SJ/T 11364-2024)
Hazardous Area (cNRTLus) Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D (T4 @ Ta= -20 degC to +65 degC)
Hazardous Area (ATEX/IECEx) II 3 G Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta= -20 degC to +65 degC)
Maritime ABS-Marine and Offshore Applications; DNV GL Rules for Classification
Loading product navigation…

Where is the I/O module installed in the 3500 system rack?

The module installs in 1 full-height rear slot directly behind the matching monitor module.

Which transducer types can connect to this external termination module?

The device accepts Proximitor, accelerometer, Velomitor, and HTVS transducer inputs.

What cable is used to connect the module to the external termination block?

The module connects via the 129525 transducer signal to external termination block cable.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendemos mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Aceitamos devoluções de produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso site oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Color pattern
Prata
Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Modernização das IHMs Bailey INFI 90 Symphony executadas no OpenVMS Alpha

Um guia prático para substituir estações de operação Bailey Symphony antigas que rodam no OpenVMS Alpha. Ele compara a emulação de Alpha, a migração para OpenVMS x86, a reimplantação em OPC e a...

Por que os dados de manutenção são essenciais para a confiabilidade industrial

Os dados de manutenção conectam ordens de serviço, sinais de sensores, histórico de ativos, custos e conhecimento dos técnicos. Quando bem utilizados, melhoram o planejamento, a confiabilidade, a...

Atuadores elétricos projetados para substituir sistemas de energia fluida: um guia prático de automação industrial

Este artigo explica como atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações matemáticas usando o OpenPLC para aplicações de automação industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas fundamentais, como adição, subtração, multiplicação, divisão, módulo e exponenciação, na automação industrial. Ele mostra como...