1 de 3

Bently Nevada 3500/04-01 136719-01 Earthing I/O Module

Bently Nevada 3500/04-01 136719-01 Earthing I/O Module

Apenas 4 item(ns) restante(s) em estoque
  • Fabricante: Bently Nevada

  • Nº do Produto: 136719-01

  • País de origem:Estados Unidos

  • Tipo de Produto: Earthing I/O Module

  • Código de barras: 8537101190

  • Pagamento: T/T, Western Union

  • Peso: 400g

  • Dimensões: 241 mm x 24.4 mm x 103.1 mm (H x W x D)

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

The Bently Nevada 136719-01 (part of the 3500/04-01 assembly) is an Earthing I/O Module designed for intrinsically safe (IS) ground reference management within the 3500 Machinery Protection System. Installed directly into the rear of the 3500 system rack, the 136719-01 provides the essential intrinsically safe earth connection through the 3500 system backplane to interface with internal barrier monitor I/O modules. This configuration enables safe, direct interconnection with approved field transducers—such as 3300 XL Proximitor sensors, Velomitor sensors, thermocouples, and RTDs—operating in hazardous environments without requiring external barriers or compromising system performance.

Features

  • Provides the intrinsically safe ground connection for internal barrier I/O modules via the 3500 system backplane.
  • Installs in a dedicated monitor position within the standard 3500 Machinery Protection System rack.
  • Fully integrated backplane routing eliminates the need for external zener or galvanic isolation barrier units.
  • Supports combined rack layouts hosting both internal barrier modules and standard I/O modules.

Applications

  • Intrinsically safe field wiring grounding for 3500 Machinery Protection Systems in hazardous industrial areas.
  • Turbomachinery vibration, speed, position, and temperature monitoring systems requiring IS loop protection.

Ordering Information

Part Number / Option Code Description
3500/04-AA-BB 3500/04 Internal Barrier System
A: I/O Module Type 01 Earthing I/O Module
B: Agency Approval

00 None

01 North American Hazloc

02 Multi (CSA, ATEX, IECEx)

136719-01 Earthing I/O Module (Spare Part)
138257-01 Earthing Module Front Panel (Spare Part)

Technical Specifications

Specification Category Parameter / Value
Manufacturer Bently Nevada
Module Type Earthing I/O Module (3500/04 IS Earthing Module)
Dimensions (H x W x D) 241 mm x 24.4 mm x 103.1 mm (9.50 in. x 0.96 in. x 4.06 in.)
Weight 0.201 kg (0.443 lb.)

Installation Guidelines

  • Rack Slot Allocation: The 136719-01 IS Earthing Module requires a dedicated monitor position in the rack, which limits a standard 19-inch rack to 13 monitor positions.
  • Positioning: Locate the IS Earthing Module in a rack position that allows easy access for routine online maintenance. When positioned between internal barrier I/O modules, allow a minimum of two rack positions to facilitate online access.
  • Requirement: Any 3500 rack containing internal barrier I/O modules must be equipped with a 3500/04-01 IS Earthing Module to provide the backplane IS earth path.
  • Wiring Separation: Route hazardous area field wiring above the 3500 rack and safe area wiring below to maintain a minimum physical separation of 50 mm (2 in).

Compliance and Certifications

Standard / Approval Type Certificate / Standard Level
FCC Complies with Part 15 of FCC Rules
EMC Directive European Community Directive 2014/30/EU; EN 61000-6-2, EN 61000-6-4
Electrical Safety European Community Directive 2014/35/EU; EN 61010-1
Marine Classification DNV GL rules for classification; ABS Rules Part 1
cNRTLus Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC
ATEX / IECEx II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/04-01 136719-01 Earthing I/O Module

Which chassis slot does the earthing module occupy in the rack?

The module installs into a dedicated monitor position on the 3500 rack backplane, reducing available monitor slots to 13.

Does the earthing module require software configuration?

The module acts as a passive backplane ground reference interface and does not require independent software programming.

Can standard and internal barrier modules coexist in the same chassis?

Standard and internal barrier modules can reside in the same chassis provided the earthing module establishes backplane IS ground.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendemos mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Aceitamos devoluções de produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso site oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Color pattern
Prata
Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Modernização das IHMs Bailey INFI 90 Symphony executadas no OpenVMS Alpha

Um guia prático para substituir estações de operação Bailey Symphony antigas que rodam no OpenVMS Alpha. Ele compara a emulação de Alpha, a migração para OpenVMS x86, a reimplantação em OPC e a...

Por que os dados de manutenção são essenciais para a confiabilidade industrial

Os dados de manutenção conectam ordens de serviço, sinais de sensores, histórico de ativos, custos e conhecimento dos técnicos. Quando bem utilizados, melhoram o planejamento, a confiabilidade, a...

Atuadores elétricos projetados para substituir sistemas de energia fluida: um guia prático de automação industrial

Este artigo explica como atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações matemáticas usando o OpenPLC para aplicações de automação industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas fundamentais, como adição, subtração, multiplicação, divisão, módulo e exponenciação, na automação industrial. Ele mostra como...