1 de 1

Delta Electronics DOP-B10S615 DOP-B Series Touch Panel Human Machine Interface

Delta Electronics DOP-B10S615 DOP-B Series Touch Panel Human Machine Interface

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: Delta Electronics

  • Nº do Produto: DOP-B10S615

  • País de origem:Estados Unidos

  • Tipo de Produto: Touch Panel HMIs

  • Pagamento: T/T, Western Union

  • Peso: 8000g

  • Dimensões: 272 x 200 x 61 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver informações completas

Description

Engineered to provide high-resolution visualization and stable operator control in complex industrial environments, the Delta Electronics DOP-B10S615 is a premium 10.1-inch widescreen Touch Panel Human Machine Interface. This unit leverages a high-performance 32-bit RISC micro-controller running Delta's proprietary Real Time Operating System to deliver rapid response times, instant boot sequences, and dependable process monitoring. Equipped with a bright, widescreen TFT LCD, the DOP-B10S615 provides clear display readability for machine builders and system integrators. Integrated memory modules, including 128 MB Flash ROM and 64 MB SDRAM, ensure ample storage capacity for advanced graphic elements, multi-language recipes, and extensive alarm logs.

Features

  • High-Resolution Display: 10.1-inch widescreen TFT LCD with 1024 x 600 pixel resolution and reliable LED backlighting.
  • Dual USB Interfaces: Features one USB Host Ver 1.1 port for flash drives or peripherals and one USB Slave Ver 2.0 port for high-speed program uploads and downloads.
  • Robust Memory Architecture: 128 MB NOR Flash ROM and 64 MB SDRAM, with an additional 16 MB of dedicated backup memory.
  • SDHC Expansion: Integrated SD card slot supports high-capacity SDHC cards for long-term data logging, trend tracking, and recipe storage.
  • Acoustic Feedback: Multi-tone onboard buzzer operating between 2 kHz and 4 kHz with an 85 dB output level for operator alerts.

Applications

  • Discrete Manufacturing: Local operator station interface for packaging, textile, and assembly line machinery.
  • Process Control: Real-time process variable monitoring in water treatment facilities and chemical dosing plants.
  • Building Automation: Centralized interface panel for commercial HVAC, lighting, and environmental control systems.

Technical Specifications Table

Specification Parameter Value / Rating
Manufacturer Delta Electronics
Model Number DOP-B10S615
Display Size & Type 10.1-inch Widescreen TFT LCD
Display Dimensions 226 x 128.7 mm
Resolution 1024 x 600 Pixels
Backlight Type LED Backlight
Operating System Delta Real Time OS
Processor (MCU) 32-bit RISC Micro-controller
NOR Flash ROM 128 MB (30MB OS / 16MB Backup / 82MB User Application)
SDRAM 64 MB
Backup Memory 16 MB
Input Power Voltage 24 VDC (-10% to +15%)
Power Consumption 12 W
Backup Battery 3V Lithium Battery (CR2032 x 1)
Module Dimensions (W x H x D) 272 x 200 x 61 mm
Net Weight 1.52 kg
Shipping Weight (Calculated) 2.50 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The DOP-B10S615 belongs to Delta's legacy DOP-B widescreen series. When planning system retrofits or migrations to newer DOP-100 series panels, ensure you review physical cabinet cutout dimensions, as modern variants may utilize different bezel arrangements. Program configurations created in ScreenEditor for older DOP panels can be imported directly into Delta DOPSoft software for migration with minor adjustments to communication driver addressing.

Application Pitfalls & Engineering Notes

To maximize the operational life of the internal Flash memory, avoid setting up continuous high-frequency write operations (such as sub-second logging intervals) directly to the system Flash. Instead, utilize the integrated SDHC slot or direct data registers within a connected PLC. In high-temperature electrical panels, ensure there is at least 100mm of free space around the HMI chassis to prevent thermal throttling of the 32-bit RISC processor.

Commissioning & Wiring Tips

Always ground the Functional Ground (FG) terminal of the power input plug to a low-impedance ground source to prevent static charge buildup and high-frequency communication interference. When powering the screen, verify that the 24VDC supply lines remain within the specified range (-10% to +15%), as voltage dips below 21.6VDC during heavy inductive motor startups can lead to unexpected HMI reboots.

Installation Guidelines

CRITICAL SAFETY WARNING

Isolate and verify the de-energized state of all 24 VDC supply lines before making physical connections to the terminal block. Ensure that polarity (+ and -) is precisely aligned with the terminal layout markings on the HMI housing. Reversing power polarity or hot-swapping power terminals can lead to catastrophic damage to the internal mainboard.

1
Prepare the panel mounting cutout using the dimensions of 272 x 200 mm, ensuring the edges are smooth and free of metal burrs.
2
Ensure the waterproof sealing gasket is flat and correctly seated in the bezel groove before inserting the HMI into the cabinet cutout.
3
Install all provided mounting clamps into the HMI side slots and tighten the tension screws evenly to secure a dust-tight and moisture-resistant IP65 seal.
Loading product navigation…

What software program is used to configure the DOP-B10S615 HMI?

The DOP-B10S615 HMI is programmed using Delta's proprietary DOPSoft software, which supports screen layout design, variable tag database configuration, and system communication protocol setups.

What is the recommended power input range for stable operation?

This HMI requires a nominal 24VDC power input, with an allowable voltage range of 21.6VDC to 27.6VDC (DC24V -10% to +15%). Power consumption is rated at 12 Watts.

Can I use external memory cards with this unit?

Yes, the DOP-B10S615 is equipped with an SD card slot that fully supports standard SDHC formats, allowing for extended trend logging, receipt storage, and screen file backups.

How do I replace the battery on the DOP-B10S615?

The HMI utilizes a standard 3V CR2032 lithium coin cell battery located behind a rear access hatch. It is recommended to perform replacements while power is applied to prevent memory loss, or immediately after a fresh system backup.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...