EL3011 BECKHOFF EtherCAT Terminal 1-Channel Analog Input

EL3011 BECKHOFF EtherCAT Terminal 1-Channel Analog Input

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3011

  • Country of origin:Alemanha

  • Product Type: EtherCAT Terminal

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantidade
Ver informações completas

Product Overview

The EL3011 (EL3011) is a high-precision EtherCAT Terminal designed for capturing analog current signals within a 0 to 20 mA range. As part of the modular BECKHOFF I/O system, this 1-channel differential input module utilizes advanced 12-bit resolution technology to deliver accurate data acquisition for demanding industrial processes. Whether deployed in power generation, chemical processing, or high-speed manufacturing, the EL3011 provides the electrical isolation and signal integrity required to interface sensitive sensors with centralized control systems. Its compact 12 mm housing optimizes cabinet space while the EtherCAT protocol ensures ultra-low latency communication across the E-bus.

Differential Signal Processing and Filtering

The EL3011 stands out through its differential input technology, which effectively suppresses common-mode interference—a critical requirement in electrically noisy environments. With a default conversion time of 0.625 ms and an internal input filter limit frequency of 1 kHz, the module balances speed with signal stability. Engineers can further refine data quality using the module’s activatable FIR/IIR filters and integrated limit value monitoring. This allows for real-time preprocessing of signals, reducing the computational load on the primary PLC and ensuring that only clean, actionable data enters the process image.

Technical Specifications

Attribute Specification Details
Model EL3011
Brand BECKHOFF
Input Type 1-Channel Analog Input (Differential)
Signal Range 0 to 20 mA
Resolution 12 bit (16 bit presentation)
Conversion Time 0.625 ms (Default, Configurable)
Measuring Error < ±0.3 percent (Relative to full scale)
Internal Resistance typ. 85 Ohm + diode voltage
Electrical Isolation 500 V (E-bus/signal voltage)
Operating Temp -25 to +60 Celsius
Dimensions 12 mm x 100 mm x 68 mm
Weight approx. 55 g

Engineering FAQ & Diagnostics

How does the 12-bit resolution translate to the 16-bit process image?

The EL3011 hardware captures data at a 12-bit depth. For software compatibility within the EtherCAT ecosystem, this value is mapped into a 16-bit integer format (sign-extended). This ensures that the PLC receives a standardized data width while maintaining the specific accuracy of the 12-bit hardware converter.

What are the benefits of the integrated FIR/IIR filters?

These digital filters allow users to suppress specific frequency interference (like 50 Hz or 60 Hz line noise). By activating these filters via the CoE (CanOpen over EtherCAT) directory, you can achieve a significantly higher signal-to-noise ratio in environments with heavy electromagnetic motor interference.

What happens if the input current exceeds 20 mA?

The module features a surge voltage resistance of 35 VDC. However, sustained current significantly above the 20 mA threshold may saturate the 12-bit converter. The integrated limit value monitoring can be configured to trigger an error bit in the process image to alert the operator of an over-range condition.


Field Wiring and Installation Guide

  • Differential Connection Integrity: To maximize the benefits of the differential input, ensure that both signal wires (positive and negative) are twisted together and shielded. Connect the shield to the designated ground terminal on the terminal block or the DIN rail via a shield bus to drain high-frequency noise.

  • Spring-Loaded Termination: The EL3011 utilizes a screwless tension spring connection. Use a standard flat-head screwdriver to actuate the spring. Ensure the stripping length is exactly 8 to 9 mm; exposed copper outside the terminal or insulation trapped inside the spring will lead to intermittent signal loss or increased resistance.

  • E-Bus Power Planning: This module consumes typically 130 mA from the E-bus. When designing your terminal island, calculate the total current draw of all connected EL-series modules to determine if an additional EK1110 or EL9410 power supply terminal is required to maintain E-bus voltage stability.

Technical Advantages and Robustness

Designed for global deployment, the EL3011 carries ATEX and UL certifications, making it suitable for hazardous areas (Ex nA IIC T4 Gc). Its polycarbonate construction and IP20 rating provide a rugged shell that conforms to EN 60068 standards for vibration and shock resistance. The module’s ability to operate in temperatures as low as -25 Celsius makes it an ideal candidate for outdoor control cabinets in infrastructure and energy sectors.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Branco Acinzentado
Country of origin
Alemanha

Recently Viewed Products

Technical knowledge

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...

Configuração de Controle de Movimento de Eixo Único com Drives Servo CMZ

Este tutorial explora a comissionamento de um sistema de movimento servo de eixo único usando um drive CMZ SBD, abrangendo a configuração de hardware, escala do eixo, configuração de homing e...