Description

Designed for seamless integration into Fail Safe Control (FSC) safety systems, the Honeywell 10006/2/1 serves as a reliable diagnostic and battery module (DBM). This unit, also referenced under part number 3400310, provides an engineered, cost-effective interface for diagnosing system health, executing runtime checks, and maintaining memory registers.

The module is equipped with an integrated real-time clock displaying minimal drift and a dedicated backup battery circuit to ensure continuous operation of critical system registers during power cycles. Engineered specifically for high-availability environments, variants bearing the 08801 suffix code feature enhanced electromagnetic noise immunity, making them highly suitable for electrically noisy industrial settings.

Features

  • Provides a dedicated diagnostics interface for Honeywell FSC safety systems.
  • Integrated real-time clock with an exceptionally low drift rate of less than 1 second per day.
  • Onboard 0.5 Ah backup battery capacity to safeguard system configuration data.
  • Enhanced noise immunity on units designated with suffix code 08801.
  • Standard 3U height and 8 HP width form factor for simple rack integration.
  • Compatible with FSC software versions 2.90 and higher.

Applications

  • Emergency Shutdown Systems (ESD)
  • Burner Management Systems (BMS)
  • Fire and Gas Detection Systems
  • Critical Process Safety control in Oil & Gas and Petrochemical plants

Technical Specifications

ManufacturerPart Number / ModelSystem CompatibilityModule TypeRequired Software VersionPower SupplyCurrent ConsumptionRipple ContentBack-up Battery CapacityTime Clock DriftModule Width (Space Requirement)Module Height (Space Requirement)Weight
Honeywell
10006/2/1 (3400310)
Honeywell Fail Safe Control (FSC) System
Diagnostic and Battery Module (DBM)
>= 2.90
5 Vdc
300 mA
< 50 mV p-p
0.5 Ah
< 1 second per day
8 TE / HP
3 HE / U
0.24 kg

Installation Guidelines

  • Electrostatic Discharge (ESD) Protection: Always wear an approved grounding wrist strap when handling the card to prevent ESD damage to delicate static-sensitive CMOS components.
  • Chassis Mounting: Ensure the FSC rack chassis is powered down prior to inserting or removing the module to avoid diagnostic communication interruptions or backplane bus faults.
  • Alignment: Slide the module carefully along the guide rails of the designated 3U subrack slot until the rear DIN connector is completely mated with the backplane. Secure the front panel using the integral retaining screws.
  • Battery Commissioning: Check battery connection jumpers or software register states upon initial startup to verify that the 0.5 Ah backup circuit is fully engaged.

Compliance and Certifications

  • CE Compliant
  • TÜV Certified for Functional Safety
  • UL Listed
Loading product navigation…

What is the primary function of the Honeywell 10006/2/1 module?

The Honeywell 10006/2/1 is a Diagnostic and Battery Module (DBM) designed for FSC safety systems. It provides a diagnostic interface for system troubleshooting, runs the system clock, and uses a 0.5 Ah backup battery to maintain memory parameters during power losses.

What is the significance of the 08801 suffix code on this DBM module?

Modules carrying the suffix code 08801 are manufactured with upgraded components that provide improved electromagnetic noise immunity, preventing interference from disturbing diagnostic operations in heavy industrial fields.

What software version is required to use this module?

The 10006/2/1 Diagnostic and Battery Module is compatible with Honeywell FSC system software versions 2.90 and higher.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...