1 de 1

Honeywell 51304419-150 MC-IOLX02 Standard I/O Link Extender Card

Honeywell 51304419-150 MC-IOLX02 Standard I/O Link Extender Card

Apenas 2 item(ns) restante(s) em estoque
  • Fabricante: Honeywell

  • Nº do Produto: 51304419-150

  • País de origem:Estados Unidos

  • Tipo de Produto: DCS I/O Modules

  • Pagamento: T/T, Western Union

  • Peso: 2000g

  • Dimensões: 310 mm x 240 mm x 50 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Providing critical signal extension and isolation within Honeywell Distributed Control Systems (DCS), the Honeywell 51304419-150 is a conformally coated MC-IOLX02 Standard I/O Link Extender Card designed to extend the physical range of redundant I/O Link communication paths. This module ensures stable, deterministic data transmission between local Process Manager I/O (PMIO) cabinets and remote I/O files. To survive harsh processing facilities, the assembly features a specialized conformal coating layer protecting the circuitry against humidity, moisture, and corrosive atmospheric pollutants.

Features

  • Conformal Coating: Provides certified environmental protection against high humidity and active chemical gases, maintaining electrical insulation integrity over long operational lifespans.
  • I/O Link Extension: Extends communication distances for standard PMIO links, allowing flexible field placement of I/O cabinets.
  • Redundancy Compatible: Engineered to function in matched pairs to ensure high-availability control system topologies without a single point of failure.
  • CE Compliant Design: Designed and manufactured to meet modern European electromagnetic compatibility (EMC) and electrical safety directives.

Applications

  • Honeywell TDC 3000 and Experion PKS PMIO architectures.
  • Remote physical expansion of Honeywell High-Performance Process Manager (HPM) systems.
  • Environments with ISA Class G3 harshness levels, such as petrochemical plants, chemical refineries, and pulp and paper mills.

Technical Specifications

Parameter Specification Value
Manufacturer Honeywell
Part Number / SKU 51304419-150
Model Number MC-IOLX02
Module Type Standard I/O Link Extender Card
Conformal Coating Yes (Fully coated assembly)
CE Compliance Yes (Compliant)
Compatibility Honeywell TDC 3000 / Experion PKS PMIO Carriers
Shipping Weight (Calculated) 2.0 kg
Packaging Dimensions (Calculated) 310 mm x 240 mm x 50 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The CE-compliant 51304419-150 directly replaces older, non-CE compliant variations of the MC-IOLX02 module line. Ensure that all redundant link extender pairs feature matching firmware/revision levels to avoid signal synchronization or communication dropouts during failover events.

Application Pitfalls & Engineering Notes

In older HPM installations, improper routing of coax and fiber cables associated with link extenders can cause signal attenuation. Ensure that bend radii for communication media conform to Honeywell site planning guidelines to prevent packet loss. The MC-IOLX02 must reside on compatible PMIO carriers designed to support the specific current draw of the extender circuitry.

Commissioning & Wiring Tips

During commissioning, verify the grounding path of the I/O Link shields. High common-mode noise on the link cabling can degrade communication speed and trigger redundant switchovers. Check the integrity of the coaxial connectors using an appropriate RF power or network analyzer if intermittent Link Error flags occur in the Experion System Status Display.

Installation Guidelines

CRITICAL WARNING

Always isolate power from the card carrier before inserting or extracting the 51304419-150 card. Hot-plugging in non-rated environments can cause electrical arcs, transient damage to adjacent modules, and CPU faults.

1

Perform a controlled shutdown of the target I/O Link branch if a redundant pair is not actively available to handle field operations.

2

Wear a calibrated ESD wrist strap grounded directly to the cabinet framework before removing the card from its protective packaging.

3

Align the card with the carrier guide rails and push firmly until the card connector is completely seated and locked into the backplane.

4

Power up the carrier, observe the card initialization LED diagnostic sequence, and verify correct system diagnostic status via the Experion PKS console.

Loading product navigation…

What is the primary role of the Honeywell 51304419-150 card?

It acts as an I/O Link Extender (MC-IOLX02) designed to extend standard high-speed communication lines between Honeywell PMIO backplanes and remote I/O files.

Does the 51304419-150 feature conformal coating?

Yes, this model features complete conformal coating protection, safeguarding internal components from corrosion due to humidity and chemical exposure.

Can I replace an older non-CE extender card with the 51304419-150?

Yes, this CE-compliant model is designed as a direct replacement for older, non-compliant configurations on standard Honeywell I/O Link environments.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...