1 de 1

Honeywell C7076D1027/U C7076 Series Mechanical Shutter with Coil

Honeywell C7076D1027/U C7076 Series Mechanical Shutter with Coil

Apenas 3 item(ns) restante(s) em estoque
  • Fabricante: Honeywell

  • Nº do Produto: C7076D1027/U

  • País de origem:Estados Unidos

  • Tipo de Produto: Flame Detector Accessories

  • Pagamento: T/T, Western Union

  • Peso: 500g

  • Dimensões: 160 mm x 160 mm x 135 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed directly for integration into high-reliability dynamic self-checking flame monitoring systems, the Honeywell C7076D1027/U provides essential safety-critical mechanical modulation for flame detection setups. This industrial shutter assembly periodically blocks the sensor's line of sight, allowing the burner controller to verify the integrity of the ultraviolet sensor and detection circuitry during run conditions. Engineered with a robust 1-inch NPT connection and explosion-proof NEMA 7 housing, it delivers continuous, failsafe performance in severe-duty environments without compromising system uptime.

Features

  • Robust Connection: Standard 1-inch NPT mechanical threading for direct, secure integration into burner housings.
  • Explosion-Proof Housing: Built to meet strict NEMA 7 protection standards, ensuring safe deployment in classified hazardous locations.
  • Dynamic Self-Checking: Allows continuous checking of UV sensor response to prevent false-flame safety hazards.
  • Broad Temperature Range: Rated for reliable operation in extreme ambient temperatures ranging from -40 degC to 71 degC.
  • Industrial Coil Design: Features a high-duty cycle solenoid shutter coil optimized for 120 VAC systems.

Applications

  • Industrial boiler and burner systems requiring dynamic self-checking flame detection.
  • Hazardous-area installations including oil refineries, chemical processing plants, and power generation facilities.
  • Multi-burner combustion setups integrated with Honeywell C7076 flame detector systems.

Technical Specifications

Parameter Specification Value
Manufacturer Honeywell
Model Number C7076D1027/U
Product Type Mechanical Shutter with Coil
Mechanical Connection 1 inch NPT
Supply Voltage 110-120 VAC (Shutter coil: 120 V only)
Frequency 50/60 Hz
Protection Class NEMA 7 (Explosion-proof)
Ambient Temperature Range -40 degC to 71 degC (-40 degF to 160 degF)
Approvals Approved for use in USA only
Shipping Weight (Calculated) 2.2 kg / 4.85 lbs
Package Dimensions (Calculated) 160 mm x 160 mm x 135 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The C7076D1027/U shutter is built specifically for Honeywell C7076 ultraviolet flame detector systems. Verify your controller's dynamic self-checking cycle timing (typically a few cycles per second) to guarantee correct matching with this heavy-duty 120V coil. If retrofitting older installations, ensure your local regulatory codes permit units restricted to USA-only approval standards.

Application Pitfalls & Engineering Notes

Continuous, rapid cycling of the mechanical shutter generates magnetic and thermal stress within the solenoid coil. If ambient temperatures consistently border the maximum limit of 71 degC, install high-quality insulation barriers or instrument-air cooling lines to avoid premature coil degradation. A stuck shutter will trigger a false-flame failure lockout on the safety burner management controller, interrupting operation.

Commissioning & Wiring Tips

When routing the 120 VAC power line to the shutter coil, use a dedicated conduit path separated from high-sensitivity flame signal coaxial cabling. This physical isolation prevents induction of electromagnetic noise that can distort low-microamp flame feedback signals, ensuring clean flame verification pulses during active self-check routines.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all electrical power sources driving the combustion control loops and the detector shutter coil before commencing installation. Ensure the installation atmosphere is fully cleared of flammable gases to prevent ignition hazards during mechanical and conduit connection operations.

1 Inspect the 1-inch NPT connection threads on both the shutter assembly and the flame detector housing to ensure they are free of debris and damage.
2 Apply high-temperature, industrial-grade pipe thread sealant to the male NPT threads, taking care not to contaminate the optical path of the shutter opening.
3 Thread the shutter assembly securely onto the mounting port. Tighten until mechanically sealed, ensuring correct orientation for the conduit connection.
4 Terminate the 120 VAC coil connections within the certified NEMA 7 junction box, maintaining strict compliance with national and local explosion-proof conduit sealing codes.
Loading product navigation…

What is the primary function of the C7076D1027/U shutter?

The mechanical shutter periodically interrupts the optical path of the Honeywell C7076 flame detector, allowing the burner safety controller to dynamically self-check the sensor's functional responsiveness while the system is firing.

What power rating does the solenoid coil require?

The solenoid shutter coil is designed for 110-120 VAC supply voltage at 50/60 Hz, with optimal performance rated at 120 V.

In what atmospheres can this mechanical shutter be installed?

It features a NEMA 7 explosion-proof protection rating, making it suitable for hazardous locations where combustible gases or vapors may be present, within its approved operating limits.

Are there regional approval restrictions for the C7076D1027/U?

Yes, this specific product model variant is certified and approved for industrial installations within the United States only.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Operações Matemáticas Usando a Plataforma OpenPLC

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...