1 de 1

Honeywell FS-PSU-240516 CC V1.1 Safety Manager Power Supply Unit

Honeywell FS-PSU-240516 CC V1.1 Safety Manager Power Supply Unit

Apenas 8 item(ns) restante(s) em estoque
  • Fabricante: Honeywell

  • Nº do Produto: FS-PSU-240516 CC V1.1

  • País de origem:Estados Unidos

  • Tipo de Produto: PLC Power Supply Modules

  • Pagamento: T/T, Western Union

  • Peso: 3000g

  • Dimensões: 21.2 cm x 3.52 cm x 17.6 cm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed for seamless integration into high-integrity safety architectures, this Honeywell FS-PSU-240516 CC V1.1 power supply module converts and regulates input power to sustain demanding system logic loads. Purpose-built for the Honeywell Safety Manager and Fail Safe Controller (FSC) systems, it provides stabilized 24 Vdc and 5 Vdc outputs with a combined capacity of 16 A. The CC designation denotes conformal coating, providing superior resistance against moisture, dust, and corrosive industrial atmospheric agents.

Key Features

  • Conformal Coated (CC): Enhanced circuit board protection for installation in harsh, corrosive Class G3 environments.
  • Dual-Output Capabilities: Delivers concurrent power regulation for 24 Vdc safety loops and 5 Vdc internal chassis logic.
  • Robust Low Inrush Design: Restricts inrush current to less than 5 A at nominal 24 Vin to prevent upstream breaker tripping.
  • Critical Fault Tolerance: Engineered to provide immediate power bridging during brief mains disruptions.

Applications

  • Emergency Shutdown Systems (ESD) and Fire and Gas (F&G) monitoring networks.
  • Burner Management Systems (BMS) in chemical processing facilities and power generation plants.
  • Critical infrastructure process control loops requiring certified SIL-rated safety architectures.

Technical Specifications

Manufacturer Honeywell
Model / SKU FS-PSU-240516 CC V1.1
Nominal Output Voltage 24 Vdc and 5 Vdc
Maximum Rated Current 16 A
Input Supply Range 24 Vdc (-15% to +30%)
Inrush Current Less than 5 A at 24 Vin
Hold-up Time Less than 1 ms
Conformal Coating Yes (CC version)
Operating Temperature -5 degC to +70 degC (+23 degF to +158 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Relative Humidity 10% to 95% (non-condensing)
Dimensions (L x W x H) 21.2 cm x 3.52 cm x 17.6 cm
Net Weight 0.85 kg
Shipping Weight (Calculated) 3.00 kg
System Certifications CE, TUV, UL, CSA, FM

Empirical Engineering Insights

Alternative Models & Compatibility

This model replaces standard non-conformal coated variations (FS-PSU-240516). Systems requiring backward compatibility with firmware Safety Manager R120 or earlier must verify card-carrier physical clearances and revision profiles, as version 1.1 features an optimized heat-sink footprint.

Application Pitfalls & Engineering Notes

When housing multiple FS-PSU modules within a tightly enclosed safety panel, thermal stratification can lead to accelerated component aging. Maintain a minimum vertical spacing clearance of 50 mm above and below the card chassis to permit convection airflow and ensure the ambient local temperature remains below +70 degC.

Commissioning & Wiring Tips

Always verify feed circuit supply integrity. The input tolerance allows 24 Vdc input variations from -15% to +30%, but keeping the incoming voltage at a stable nominal 24 Vdc optimizes internal regulator efficiency and minimizes excessive heat dissipation within the module's enclosure.

Installation Guidelines

CRITICAL WARNING: SAFETY FIRST

Isolate and lockout all active primary power feeds prior to physical module replacement. Working on energized components in safety-instrumented systems poses severe risks of accidental ESD system trip, electrical shock, and hardware degradation.

1 Ensure the power supply card frame is securely connected to the system functional earth ground network.
2 Align the backplane guide pin connectors carefully before pushing the FS-PSU module into the rack slot.
3 Tighten the retaining screws securely to a torque of 0.5 Nm to prevent vibration-induced contact resistance.
Loading product navigation…

What does the 'CC' designation indicate in this Honeywell power supply?

The 'CC' code indicates Conformal Coating. The printed circuit board is coated with an engineering polymer to protect the electronics from harsh environmental hazards such as industrial moisture, dust, and Class G3 corrosive gases.

Can this unit be used in SIL-3 safety loops?

Yes. The FS-PSU-240516 CC V1.1 is designed and certified as part of Honeywell's Safety Manager system, which is certified for use in Emergency Shutdown and fire and gas safety applications up to SIL-3.

What is the maximum output current limit for this power supply module?

This module provides a dual-rail output of 24 Vdc and 5 Vdc with a combined maximum continuous output rating of 16 A.

How does the FS-PSU-240516 CC handle startup inrush current?

It features an engineered low-inrush circuit limiting the startup peak current to less than 5 A at a nominal input of 24 Vin, minimizing potential disturbances on the upstream distribution bus.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...