Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: Mitsubishi Electric

  • Nº do Produto: FR-A840-00380-2-60

  • País de origem:Estados Unidos

  • Tipo de Produto: Frequency Inverters

  • Pagamento: T/T, Western Union

  • Peso: 9300g

  • Dimensões: 220 mm x 300 mm x 190 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed for precise, high-performance motor control, the FR-A840-00380-2-60 is a variable frequency drive belonging to the premium Mitsubishi Electric FR-A800 series. This three-phase inverter provides dynamic vector control and high torque capability, making it well-suited for demanding heavy-duty industrial applications. Operating on a 400/415V AC input voltage, it features dual rating capabilities to maximize operating efficiency depending on load characteristics.

The unit incorporates an integrated Mitsubishi L-Series PLC with up to 6K steps of program memory, allowing users to implement decentralized control schemes directly within the drive. Backwards compatibility with the legacy FR-A700 series ensures minimal system downtime during upgrades. For communication and commissioning, the drive features a built-in USB Type A port, standard support for SSCNet, and direct plug-and-play interfacing with Mitsubishi GOT2000 HMIs.

Features

  • Real Sensorless Vector Control and Closed-Loop Vector Control up to 400 Hz.
  • Built-in Mitsubishi L-Series PLC functionality with up to 6K steps program memory.
  • Dual-rating system optimized for both Constant Torque and Variable Torque loads.
  • Optimum Excitation Control technology, reducing motor energy consumption by up to 12%.
  • Integrated temperature sensor for continuous thermal monitoring and preventative maintenance.
  • Support for external 24V DC control circuit power to maintain diagnostics and communications during main line isolation.
  • Equipped with an integrated brake chopper for effective regenerative braking up to 55kW.
  • Password-protected parameter configurations and PLC programs to safeguard intellectual property.

Applications

  • Winding and unwinding machinery requiring high-precision tension control.
  • Crane hoisting, gantry, and travel drives.
  • Machine tool spindles and high-speed positioning units.
  • Conveyor networks and continuous material handling equipment.

Technical Specifications

Parameter Value
Manufacturer Mitsubishi Electric
Model Number FR-A840-00380-2-60
Series FR-A800
Input Voltage Range Three-phase 380 to 500 V AC, 50/60 Hz
Nominal Motor Power Rating 15 kW (ND / Heavy Duty) / 18.5 kW (LD / Normal Duty)
Rated Current Output 31 A (ND) / 38 A (LD)
Inverter Type Variable Frequency Drive (VFD)
Control Methods V/F Control, Real Sensorless Vector Control, Closed-Loop Vector Control, PM Sensorless Vector Control
Enclosure Protection Class IP20
External 24V DC Input Supported (Control circuit only)
Dimensions (W x H x D) 220 mm x 300 mm x 190 mm
Approximate Shipping Weight 9.3 kg

Installation Guidelines

When mounting the FR-A840-00380-2-60, ensure it is oriented vertically on a flat, non-flammable surface. Maintain a minimum vertical clearance of 100 mm above and below the unit, and 50 mm clearance on either side to allow proper heat dissipation from the cooling fans. Wiring must be routed inside dedicated, grounded metallic conduits to minimize electromagnetic interference (EMI). Always ensure a solid, low-impedance system ground is connected directly to the drive ground terminal.

Compliance and Certifications

  • Functional Safety: PLd (EN ISO 13849-1) and SIL2 (IEC 61508) as standard.
  • CE compliant.
  • UL listed and cUL certified.
Loading product navigation…

What is the power rating of the FR-A840-00380-2-60 inverter?

The FR-A840-00380-2-60 has a nominal power rating of 15 kW for constant torque / normal duty applications, and up to 18.5 kW for variable torque / light duty applications.

Can the control logic of this VFD be kept alive when the main power is turned off?

Yes, an external 24V DC power supply can be connected directly to the control terminals. This allows the user to access parameters, maintain communication networks, and perform safety maintenance without 400V AC main power applied.

Is there a built-in PLC in the Mitsubishi FR-A800 series?

Yes, the FR-A840-00380-2-60 features a built-in Mitsubishi L-Series PLC supporting up to 6K steps of program memory for customized local control sequences.

What is the environmental protection class of this drive?

This module features an IP20 open-chassis protection rating and must be installed inside an appropriate industrial enclosure to protect against dust and liquid ingress.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...