1 de 1

Mitsubishi Electric FX2N-128MT-ES/UL MELSEC FX2N Series PLC Main Unit

Mitsubishi Electric FX2N-128MT-ES/UL MELSEC FX2N Series PLC Main Unit

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: Mitsubishi Electric

  • Nº do Produto: FX2N-128MT-ES/UL

  • País de origem:Estados Unidos

  • Tipo de Produto: PLC CPU Modules

  • Pagamento: T/T, Western Union

  • Peso: 2800g

  • Dimensões: 365 mm x 125 mm x 110 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver informações completas

Designed for high-speed machine control and extensive local I/O integration, the Mitsubishi Electric FX2N-128MT-ES/UL serves as a high-density processing core within the MELSEC FX2N Series PLC family. This main unit features a combined total of 128 local I/O points, utilizing transistor source outputs and highly configurable sink/source inputs to manage complex automation sequences in demanding industrial environments.

Key Technical Features

  • High-Density I/O Configuration: Equipped with 64 digital inputs and 64 transistor outputs (source format) integrated into a single compact chassis.
  • Advanced Processing Speed: Executes basic instructions at 0.08 microseconds per instruction, ensuring rapid response times for critical control loops.
  • Flexible Memory Architecture: Features an 8,000-step internal RAM (battery-backed) with expansion capabilities up to 16,000 steps via memory cassettes.
  • Integrated High-Speed Counters: Supports up to 6 channels of high-speed inputs with counting frequencies up to 60 kHz for precise positioning and encoder feedback.
  • Dual-Axis Positioning: Built-in independent 2-axis pulse output (up to 20 kHz) for direct control of stepper and servo drive systems.

Industrial Applications

  • Multi-Axis Packaging Machinery: Controls high-speed wrapping, sealing, and labeling systems requiring synchronized pulse outputs.
  • Material Handling & Conveyor Systems: Manages complex sorting, routing, and tracking configurations across extensive conveyor networks.
  • Assembly and Pick-and-Place Stations: Interfaces directly with pneumatic actuators, sensors, and variable frequency drives.
  • Specialized Machine Tooling: Provides reliable logic control for custom drilling, cutting, and metal-forming machinery.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Mitsubishi Electric
Model Number FX2N-128MT-ES/UL
Product Series MELSEC FX2N
Rated Supply Voltage 100 to 240V AC (50/60 Hz)
Power Consumption 65W
Internal 24V DC Service Power 460mA or less
Digital Inputs 64 points (Sink/Source selectable, DC24V +/- 10%)
Digital Outputs 64 points (Transistor / Source type, 5 to 30V DC)
Output Current Rating 0.5A per point (0.8A per 4-point common, 1.6A per 8-point common)
Input Impedance 3.3k Ohm (X000 to X007), 4.3k Ohm (X010 and higher)
Isolation Method Photocoupler isolation
Connection Type Removable terminal blocks (M3 screws)
Country of Origin Japan
Shipping Weight (Calculated) 1.80 kg
Package Dimensions (Calculated) 365 mm x 125 mm x 110 mm

Connections and Interfaces

Terminal / Port Functional Assignment
L, N, Ground Main AC Power Input (100 to 240V AC) and Protective Earth
24V, 0V DC24V Service Power Output (for powering external sensors/switches)
S/S Sink / Source selection terminal for digital input circuits
X000 to X077 64 Digital Input Channels (Octal numbering system)
Y000 to Y077 64 Transistor Source Output Channels (Octal numbering system)
+V0 to +V7 External DC Power supply inputs for transistor output groups

Empirical Engineering Insights

Alternative Models & Compatibility

The FX2N-128MT-ES/UL is the global standard model featuring transistor source outputs. It directly replaces older Japanese-market sink-only models (such as the FX2N-128MT-D) in systems where field wiring has been updated to source logic. When migrating legacy applications to the modern MELSEC FX3U series (e.g., FX3U-128MT/ESS), program conversion can be executed via GX Works2, though physical depth and terminal block spacing must be cross-referenced to ensure panel layout compatibility.

Application Pitfalls & Engineering Notes

Ensure that the cumulative current drawn from the 24V DC service power terminals does not exceed 460mA. Overloading this internal supply will cause thermal shutdown or erratic CPU behavior. Additionally, because the transistor outputs are rated for a maximum of 0.5A per single point, inductive loads such as heavy solenoids or magnetic contactors must be suppressed using external flyback diodes to prevent premature output degradation.

Commissioning & Wiring Tips

For high-speed counter inputs (X000 to X007), always use shielded twisted-pair cabling. Route these signal lines completely separate from high-voltage AC power lines and VFD motor cables to prevent electromagnetic interference from corrupting pulse counts. If using the built-in pulse output functions (Y000 and Y001) for positioning, verify that the external load impedance is high enough to limit current draw to 0.3A on these specific high-speed channels.

Installation Guidelines

CRITICAL WARNING:

Disconnect all external power sources before attempting installation, wiring, or module replacement. Residual charges in the internal capacitors can cause electrical shock or damage sensitive internal CMOS components. Ensure the protective earth terminal is connected to a dedicated class-D ground point.

1

Mount the controller vertically on a standard 35mm DIN rail or directly to the backplate using the integrated mounting holes. Maintain at least 50mm of clearance above and below the unit for natural convection cooling.

2

Wire the AC power supply to the L and N terminals using minimum 1.25 mm² (AWG 16) conductors. Install a 5A slow-blow fuse on the hot line prior to the terminal block.

3

Configure the S/S terminal according to your field sensor logic: connect S/S to 24V for NPN (sink) input configurations, or to 0V for PNP (source) input configurations.

4

Secure all terminal screws to a torque rating of 0.5 to 0.8 N-m to prevent loose connections and potential thermal faults during operation.

What is the difference between the ES/UL and the ESS/UL models?

The ES/UL suffix designates standard AC power, sink/source inputs, and transistor source outputs. It is fully compliant with European and UL standards, making it the standard choice for global machinery exports.

Can I use the FX2N-128MT-ES/UL to control servo drives directly?

Yes. The unit features 2 independent axes of pulse output (Y000 and Y001) capable of delivering up to 20 kHz pulse trains, which can directly control stepper or servo drives in positioning applications.

What battery is required to maintain the program memory on this PLC?

The unit uses a built-in lithium battery (typically model FX2N-BAT) to back up the 8,000-step RAM memory, internal relays, and data registers when the main power is disconnected.

How do I switch the digital inputs between sink and source modes?

The input mode is determined by the wiring of the S/S terminal. Connecting the S/S terminal to the 24V terminal configures the inputs for sink (NPN) sensors. Connecting S/S to 0V configures them for source (PNP) sensors.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...