Description

Designed to execute high-precision motion profiles within the MELSERVO-J3 system architecture, the Mitsubishi Electric MR-J3-60B AC servo amplifier offers high-speed control loops and synchronized multi-axis coordination. Equipped with a digital SSCNET III fiber-optic communication interface, this drive integrates directly into complex industrial automation configurations to minimize latency and ensure noise-free signal transmission. It operates with high-resolution feedback systems to guarantee positioning accuracy, making it ideal for processes requiring tight speed constancy and dynamic performance.

Features

  • SSCNET III Bus Interface: High-speed, noise-immune synchronous optical fiber network communication for precise multi-axis positioning and coordination.
  • High-Resolution Feedback compatibility: Seamless processing of 18-bit absolute/incremental encoder signals providing 262,144 pulses per revolution.
  • Adaptive Vibration Suppression: Advanced filtration system designed to minimize mechanical resonance and structural oscillations during rapid deceleration or acceleration.
  • Real-Time Auto Tuning: Automatic adjustment of gain settings to optimize response according to the real-time load inertia ratio.
  • Integrated Diagnostic Port: Direct USB connection for configuration, monitoring, and trend analysis using MR Configurator software.

Applications

  • Multi-axis CNC milling, routing, and precision grinding machines.
  • Pick-and-place robots and electronic component assembly systems.
  • High-speed packaging, filling, and continuous labeling machinery.
  • Semiconductor handling machinery and wafer positioning systems.

Technical Specifications

Parameter Value
Manufacturer Mitsubishi Electric
Model Number MR-J3-60B
Series MELSERVO-J3
Rated Output Capacity 0.6 kW (600W)
Main Circuit Power Supply 3-phase or 1-phase 200 to 230 VAC, 50/60 Hz
Control Circuit Power Supply 1-phase 200 to 230 VAC, 50/60 Hz
Communication Interface SSCNET III (High-speed synchronous network)
Control Method Sine-wave PWM control / Current control system
Ambient Operating Temperature 0 to 55 degC (non-freezing)
Dynamic Brake Built-in
Cooling Method Natural cooling
Shipping Weight (Calculated) 2.1 kg

Connections and Interfaces

Connector / Terminal Function / Circuit Assignment
CN1A / CN1B SSCNET III network connection ports (Optical fiber duplex connectors)
CN2 Encoder feedback connection for the HF or HC series servo motor
CN3 Digital input/output signal interface (interlock, emergency stop, limit switches)
CN5 USB communication port for PC tool setup and online diagnostics
L1, L2, L3 Main power circuit input terminal block
L11, L21 Control power circuit input terminal block
U, V, W 3-phase power output connection to servo motor windings

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating a system from the MR-J2S-60B series, note that the SSCNET III optical fiber connector format differs physically from the original SSCNET configuration. The MR-J3-60B requires specialized high-speed optical fiber cables (such as MR-J3BUS) which utilize standard locking tabs. Intermixing old and new optical connection configurations is not possible without an optical media converter or controller-level interface card replacement.

Application Pitfalls & Engineering Notes

To avoid high thermal loading in enclosed electrical cabinets, design layout spacing strictly: maintain at least 10 mm clearance on either side of the chassis, and 40 mm clearance above and below. If routing SSCNET III fiber optic cables, enforce a minimum bending radius of 25 mm. Exceeding this limit will result in optical signal attenuation, manifesting as communication timeouts or non-specific "AL.37 Parameter Error" fault triggers.

Commissioning & Wiring Tips

If configuring the absolute position detection system, always insert an active MR-BAT or MR-J3BAT battery pack before starting the system calibration. Loss of control voltage without an active battery backup instantly clears the stored encoder home coordinates, requiring manual re-homing procedures upon subsequent control system re-initialization.

Installation Guidelines

CRITICAL WARNING: Verify all AC input power feeds are completely isolated, disconnected, and locked out prior to handling any terminals. Wait a minimum of 15 minutes after power-down to allow internal high-voltage capacitors to bleed energy safely. Check that the internal red charge LED is completely extinguished before initiating any dynamic resistance or terminal verification tests.
1
Mount the servo amplifier vertically to a rigid, metallic panel surface. Secure the chassis via the mounting holes to ensure optimal heat dissipation and ground contact.
2
Wire the control circuit supply voltage terminals (L11, L21) and main input terminals (L1, L2, L3) using appropriate gauge wire, adhering to correct regional fuse/breaker guidelines.
3
Connect the motor output lines (U, V, W) to the corresponding terminals on the motor. Pay absolute attention to match phases precisely—reversing phase wiring here will trigger a run-away feedback condition and cause damage.
4
Insert the fiber optic cables securely into the CN1A and CN1B ports. Listen for an audible click confirming the mechanical locks have engaged correctly.
Loading product navigation…

What is the primary communication protocol used by this servo amplifier?

This amplifier communicates with the motion controller using the high-speed optical fiber SSCNET III protocol, ensuring deterministic, synchronous control.

Can I operate this drive with single-phase power supply parameters?

Yes, it supports both single-phase and three-phase input power between 200 and 230 VAC for the main power loop.

How do I resolve communication errors over the optical bus network?

Ensure the optical cables are clean and do not exceed the minimum bending radius of 25 mm. Check that optical fiber connectors are securely locked into CN1A or CN1B.

Does this amplifier feature dynamic braking capabilities?

Yes, the dynamic brake function is integrated into the hardware to provide auxiliary stopping force during unexpected emergency shut-down events.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Transformaram a Mineração Subterrânea

Desde compressores CC acionados por corda até carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como...