Description

Integrating seamlessly into high-speed industrial networks, the QJ71GF11-T2 serves as a high-performance communication interface within the MELSEC-Q automation platform. This module enables deterministic, high-capacity data exchange by functioning as either a master or local station on a CC-Link IE Field network. Operating at a transmission speed of 1 Gbps, it manages extensive digital and analog I/O points across distributed automation architectures, ensuring synchronized control and rapid diagnostic capabilities.

The unit supports versatile physical layouts including line, star, and ring network topologies, which can be combined to suit complex factory floor environments. Its integration within the MELSEC-Q series allows for straightforward configuration via GX Works software, reducing engineering overhead and optimizing data throughput for heavy industrial processing.

Features

  • High-Speed Communication: Operates at a physical layer speed of 1 Gbps for rapid data transmission.
  • Flexible Topologies: Supports line, star, and ring network configurations, including hybrid line/star systems.
  • Dual-Role Capability: Configurable as either a network Master Station or a Local Station.
  • Token Passing Method: Implements a deterministic token-passing communication scheme to prevent network collisions.
  • Massive Data Capacity: Handles up to 16,384 RX/RY points and 8,192 RWr/RWw words per network.
  • Extended Distances: Supports up to 100 meters between stations and up to 12,100 meters total loop distance in ring configurations.

Applications

  • Automotive assembly and robotic welding lines
  • High-speed packaging and sorting machinery
  • Water and wastewater treatment distribution systems
  • Material handling and automated warehousing systems
  • Distributed PLC-to-PLC communication links in processing plants

Technical Specifications

Manufacturer Mitsubishi Electric
Part Number / Model QJ71GF11-T2
Module Type CC-Link IE Field Network Master/Local Module
Communication Speed 1 Gbps
Station Types Master Station, Local Station
Communication Method Token passing method
Maximum RX Points 16,384 points
Maximum RY Points 16,384 points
Maximum RWr Points 8,192 points
Maximum RWw Points 8,192 points
Connection Cable Type Category 5e or higher (Double-shielded, STP) straight cable
Max Station-to-Station Distance 100 m (Compliant with ANSI/TIA/EIA-568-B Category 5e)
Max Total Distance (Line) 12,000 m (1 master and 120 slave stations)
Max Total Distance (Ring) 12,100 m (1 master and 120 slave stations)
Occupied I/O Points 32 points (I/O assignment: Intelligent 32 points)
Internal Current Consumption (5 VDC) 0.85 A
Dimensions (W x H x D) 27.4 mm x 98 mm x 115 mm
Weight 0.18 kg

Connections and Interfaces

Port Label Connector Type Functional Description
PORT1 RJ45 Primary CC-Link IE Field connection port (1000BASE-T)
PORT2 RJ45 Secondary CC-Link IE Field connection port for ring, line, or star daisy-chaining

Installation Guidelines

  • Mounting: Place the module into the standard slot of a MELSEC-Q series main or extension base unit. Secure the unit with the module fixing screw to prevent vibration-induced disconnections.
  • Cabling Requirements: Use only double-shielded, Category 5e or higher STP straight cables. Standard unshielded twisted pair (UTP) cables should not be used due to noise sensitivity at 1 Gbps speeds.
  • Noise Abatement: Route communication cables away from high-voltage cables and motor drive lines by a minimum of 100 mm to avoid electromagnetic interference.
  • Grounding: Ensure the base unit's functional ground (FG) terminal is connected to a dedicated class D ground (grounding resistance of 100 ohms or less).
Loading product navigation…

Can the QJ71GF11-T2 module be used in a CC-Link IE Control network?

No. The QJ71GF11-T2 is designed specifically for CC-Link IE Field networks and is not compatible with CC-Link IE Control networks.

Does this module support star topologies, and are hubs required?

Yes, star topologies are supported. When building a star topology, a compatible industrial switching hub (1000BASE-T compliant) is required.

What happens if a cable breaks in a ring topology setup?

In a ring topology configuration, the network will automatically perform a loopback function to keep communication active among the remaining operational stations.

How many I/O points does the QJ71GF11-T2 occupy on the PLC base unit?

The module occupies 32 points, configured as an Intelligent module within the PLC I/O assignment settings.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...