1 de 1

Omron CJ1W-DA041 CJ Series Analog Output Unit

Omron CJ1W-DA041 CJ Series Analog Output Unit

Apenas 5 item(ns) restante(s) em estoque
  • Fabricante: Omron

  • Nº do Produto: CJ1W-DA041

  • País de origem:Japão

  • Tipo de Produto: Analog Output Units

  • Pagamento: T/T, Western Union

  • Peso: 150g

  • Dimensões: 31 x 90 x 65 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed for precise digital-to-analog signal conversion within industrial automation systems, the CJ1W-DA041 serves as a high-performance analog output module for the Omron CJ series. This module enables programmable controllers to interface directly with analog control devices by converting digital process values into corresponding voltage or current signals.

Equipped with four high-accuracy channels, the CJ1W-DA041 supports standard industrial output ranges including 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, and 4 to 20 mA. It features a removable 18-point terminal block that facilitates direct wiring and convenient system maintenance, minimizing downtime during module replacement.

Features

  • Four independent, configurable analog output channels.
  • Supports multiple voltage and current output ranges for broad instrument compatibility.
  • Fast digital-to-analog conversion period of 1.0 ms per point.
  • Photocoupler isolation between backplane controller signals and output circuits.
  • Configurable output hold function to maintain, clear, or maximize output signal states during PLC stop or error conditions.
  • Removable 18-point M3 screw terminal block for streamlined installation and wiring.

Applications

  • Proportional valve positioning and control systems.
  • Variable frequency drive (VFD) speed regulation.
  • Process controllers, chart recorders, and remote indicators.
  • Multi-axis motion profiling and industrial heating control loops.

Technical Specifications

Parameter Value
Manufacturer Omron
Part Number/Model CJ1W-DA041
Module Type Analog Output Unit (CJ-series Special I/O Unit)
Number of Analog Outputs 4
Output Signal Range (Voltage) 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V
Output Signal Range (Current) 4 to 20 mA
Output Impedance (Voltage) 0.5 ohm max.
Maximum Output Current (Voltage) 12 mA
Maximum Permissible Load Resistance (Current) 600 ohm
Resolution 4,000 (16-bit binary set data)
D/A Conversion Period 1.0 ms per point
Accuracy (at 25 degC) Voltage: +/-0.3% of F.S. | Current: +/-0.5% of F.S.
Accuracy (at 0 degC to 55 degC) Voltage: +/-0.5% of F.S. | Current: +/-0.8% of F.S.
Isolation Photocoupler between I/O and Controller signals (No isolation between individual I/O channels)
Power Consumption 140 mA max. at 5 VDC
External Power Supply Requirements 24 VDC, 200 mA max. (Inrush current: 20 A max., pulse width: 1 ms min.)
External Terminals 18-point detachable terminal block (M3 screws)
Dimensions 31 x 90 x 65 mm (W x H x D)
Weight 150 g max.

Installation Guidelines

  • Always disconnect the power supply to the CJ-series PLC rack before mounting or removing the analog output module.
  • To prevent electromagnetic noise, use shielded twisted-pair cables for all analog output connections and ground the shield only at the receiving end.
  • Route analog signal wires through dedicated conduits separate from high-voltage cables and AC power lines.
  • Ensure the external 24 VDC power supply complies with the startup inrush current specifications (20 A peak) to prevent power drops during module initialization.
Loading product navigation…

What is the conversion speed of the CJ1W-DA041?

The D/A conversion period for the CJ1W-DA041 is 1.0 ms per point.

Does the CJ1W-DA041 support individual channel isolation?

No. While the module features photocoupler isolation between the I/O signals and the controller logic, there is no isolation between the individual output channels.

What happens to the analog outputs when the PLC controller stops?

The module features an output hold function. Depending on your configuration, it can hold the last state, clear the output (CLR), or set the output to maximum values (MAX).

Can the CJ1W-DA041 output both voltage and current simultaneously?

Yes, each of the 4 channels can be configured independently for either voltage (e.g., 0 to 10 V) or current (e.g., 4 to 20 mA) output ranges.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...