1 de 1

Omron CJ2M-CPU34 CJ2M Series CPU Unit with Built-in EtherNet/IP

Omron CJ2M-CPU34 CJ2M Series CPU Unit with Built-in EtherNet/IP

Apenas 2 item(ns) restante(s) em estoque
  • Fabricante: Omron

  • Nº do Produto: CJ2M-CPU34

  • País de origem:Japão

  • Tipo de Produto: PLC CPU Modules

  • Pagamento: T/T, Western Union

  • Peso: 190g

  • Dimensões: 90 mm x 75 mm x 62 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

To deliver high-speed logic execution and integrated factory network communications, the Omron CJ2M-CPU34 functions as a core processing module within the modular CJ2M Series PLC architecture. Engineered for high-speed industrial automation, this CPU supports 30K steps of program memory and up to 160K words of data memory. It features an integrated EtherNet/IP port alongside a dedicated USB programming port, eliminating the need for specialized external communication adapters. Its exceptionally fast 0.04 us LD instruction execution speed makes it highly suitable for demanding motion, packaging, and process sequencing tasks.

Key Features

  • High-Speed Processing: Logic execution speed of 0.04 us for basic instructions and 0.06 us for double-precision instructions.
  • Integrated Communication: Built-in EtherNet/IP port for seamless tag data links, message communications, and FINS TCP/IP connections.
  • Expandable Architecture: Supports up to 2,560 local digital I/O points and up to 40 I/O modules across 3 expansion racks.
  • Flexible Memory Allocations: 30K steps program capacity and 160K words of data memory, featuring DM and multiple EM banks.
  • Direct Programming Access: Standard high-speed USB 2.0 peripheral port on the front panel for rapid software monitoring and updates.

Applications

  • Packaging and Labeling: Synchronized operations with multi-station control and high-speed registration.
  • Material Handling: Distributed sorting conveyor networks, automated storage and retrieval systems (AS/RS).
  • Assembly and Testing: Precision electronic assembly machines, pick-and-place stations, and diagnostic instrumentation.
  • Process Control Integration: Remote telemetry, environmental monitoring, and factory-wide SCADA data aggregation.

Technical Specifications

Manufacturer Omron
Model CJ2M-CPU34
Series CJ2M (Built-in EtherNet/IP) CPU Units
Program Capacity 30K steps
Data Memory Capacity 160K words (DM: 32K words, EM: 32K words x 4 banks)
LD Instruction Execution Time 0.04 us
Max Local I/O Points 2,560 points
Mountable Units (Expansion Racks) 40 Units (Maximum 3 Expansion Racks)
Current Consumption (5 VDC) 0.7 A
Interfaces EtherNet/IP (RJ45), USB (Type-B), Option Board Slot
CPU Unit Dimensions 90 mm x 75 mm x 62 mm
Weight 0.19 kg
Shipping Weight (Calculated) 1.50 kg

Connections and Interfaces

Port / Connector Function / Cable Specification
EtherNet/IP Port RJ45, 100Base-TX/10Base-T. Supports Tag Data Links, FINS messages, and FTP server functions.
USB Port USB 2.0 Type-B connection. High-speed engineering connection for CX-Programmer upload/download.
Serial Option Slot Accepts optional RS-232C (CP1W-CIF01) or RS-422A/485 (CP1W-CIF11/CIF12-V1) serial option boards.

Empirical Engineering Insights

Alternative Models & Compatibility

The CJ2M-CPU34 is a direct fit-form-function replacement for legacy CJ1M-series installations, offering greater execution speed and native EtherNet/IP capabilities. Programs from CJ1M platforms can be systematically imported using CX-Programmer, though variables allocated to specific legacy registers should be verified against the extended EM banks of the CJ2M.

Application Pitfalls & Engineering Notes

While the integrated EtherNet/IP port supports heavy traffic, the internal processor prioritizes logic execution over network task allocation. High tag data link rates (over 3200 PPS cumulative) can lead to microsecond fluctuations in task cycle times. If high cyclic network throughput is expected alongside intense floating-point math, segmenting communications onto a dedicated CJ1W-EIP21 module is highly recommended.

Commissioning & Wiring Tips

The node address of the integrated EtherNet/IP interface is assigned via physical rotary switches located on the front panel of the CPU. If the IP address does not resolve, check that these hardware switch settings correspond directly to the host portion of the network IP configuration. Always run Ethernet cables distinct from high-voltage AC motor lines to avoid physical layer noise disruption.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and secondary power distribution systems connected to the CJ-series backplane before inserting or removing the CPU unit. Working on energized backplanes can cause memory corruption, damage internal components, or lead to unexpected plant machinery operation.
1
Align the hooks on the back of the CPU unit with the DIN rail structure and carefully slide the module into position next to the power supply unit.
2
Engage the yellow slider locking clips on both the top and bottom of the unit to lock the assembly firmly to the adjacent modules on the rack.
3
Secure the end plate at the final slot of the assembly to prevent physical lateral drift along the DIN rail.
4
Connect the shielded Ethernet cable (Cat5e or Cat6) to the RJ45 jack and verify the network indicator lamps light up on power-up initialization.
Loading product navigation…

What is the maximum Tag Data Link capacity for the CJ2M-CPU34 built-in EtherNet/IP port?

The built-in EtherNet/IP port on the CJ2M-CPU34 supports up to 3200 PPS (packets per second) for cyclic communication. The maximum number of connection links is 32.

Can I program the CJ2M-CPU34 without a dedicated programming cable?

Yes, the CJ2M-CPU34 features a built-in peripheral USB port (Type-B) that allows direct programming and monitoring via a standard USB-A to USB-B cable using CX-Programmer.

How do I configure the FINS node address for EtherNet/IP communications?

The FINS node address is set via the rotary switches on the front panel of the CPU unit. Ensure the rotary switch value aligns with the host IP address configuration for proper routing.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Transformaram a Mineração Subterrânea

Desde compressores CC acionados por corda até carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como...