1 de 1

Omron F3SJ-E0625P25 F3SJ Series Safety Light Curtain

Omron F3SJ-E0625P25 F3SJ Series Safety Light Curtain

Apenas 4 item(ns) restante(s) em estoque
  • Fabricante: Omron

  • Nº do Produto: F3SJ-E0625P25

  • País de origem:Japão

  • Tipo de Produto: Safety Light Curtains

  • Pagamento: T/T, Western Union

  • Peso: 4000g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Providing reliable hand protection in heavy industrial environments, the Omron F3SJ-E0625P25 safety light curtain functions as a Type 4 safeguarding sensor with a 625 mm protective height. This optoelectronic guard employs an infrared LED array with a 20 mm beam gap and 25 mm detection capability, making it ideal for detecting hands and arms as they approach hazardous machinery. Designed with simple PNP outputs and a pre-configured, non-complex functional profile (Easy Type), this unit integrates directly into safety PLC or safety relay circuits without requiring complex software setups.

Features

  • Type 4 Safety Sensor: Meets rigorous global functional safety standards for PL e (ISO 13849-1) and SIL3 (IEC 61508) architectures.
  • High-Density Beam Array: Uses 30 optical beams to maintain precise detection resolution across the entire active field.
  • Long Operating Range: Covers scanning distances from 0.2 m up to 7 m, accommodating both compact machine envelopes and wider perimeter entries.
  • Robust Environmental Sealing: Rated to IP65, providing defense against dust ingress and low-pressure water jets.
  • Simplified Wiring: Features built-in mutual interference prevention to ensure stability when multiple units are mounted in close proximity.

Applications

  • Robotic Workstations: Surrounds automated robotic arms to immediately interrupt operation if an operator breaches the working envelope.
  • Stamping and Power Presses: Protects hand and arm access zones during manual workpiece loading/unloading sequences.
  • Packaging and Conveyor Lines: Safeguards automated sorting and palletizing equipment from accidental human contact.
  • Material Handling Systems: Manages entry-exit zones where hazardous mechanical action must be paused during manual intervention.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Code F3SJ-E0625P25
Sensor Classification Type 4 (IEC 61496-1) / Category 4, PL e (EN ISO 13849-1)
Protective Height 625 mm
Detection Capability 25 mm (diameter)
Number of Beams 30
Beam Pitch (Gap) 20 mm
Operating Range 0.2 m to 7 m
Output Type 2 x PNP semiconductor outputs (OSSD)
Power Supply Voltage 24 VDC +/-20% (SELV/PELV, ripple p-p 10% max.)
Current Consumption (Emitter) 57 mA maximum (30 beams)
Current Consumption (Receiver) 47 mA maximum (30 beams)
Light Source (Wavelength) Infrared LED (870 nm)
Enclosure Protection IP65 (IEC 60529)
Net Weight 2.2 kg
Shipping Weight (Calculated) 4.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The F3SJ-E (Easy Type) serves as a streamlined alternative to the F3SJ-A (Advanced) and F3SJ-B (Basic) series. Note that the F3SJ-E features fixed functions and does not support software configurations, auxiliary outputs, or series-connection cascading. If your application demands blanking, muting, or series-linking of multiple curtains, you must transition to the F3SJ-A series, as the F3SJ-E hardware is physically incompatible with these configurations.

Application Pitfalls & Engineering Notes

Because this model utilizes fixed mutual interference prevention, mounting two F3SJ-E pairs back-to-back can cause optical cross-talk if not separated by an opaque physical barrier or oriented with opposing emitter/receiver directions. Ensure the safety distance calculation (S) complies with EN ISO 13855, accounting for the 25 mm resolution (which dictates a minimum intrusion depth factor, d, of 80 mm in the standard calculation formula).

Commissioning & Wiring Tips

Always route the OSSD output cables in separate conduits from high-power AC motor lines and Variable Frequency Drive (VFD) cabling. Inductive coupling on the OSSD feedback loops can trigger intermittent fault codes (flanking red LED diagnostics on the receiver). Ensure the 24 VDC power supply is a dedicated SELV/PELV source to prevent transient voltage spikes from damaging the internal output transistors.

Installation Guidelines

CRITICAL WARNING

De-energize all primary machine power sources before initiating installation. Verify complete absence of residual voltage in control circuits. Failure to lock out electrical and kinetic energy sources during mounting can result in severe physical injury or equipment damage. This safety light curtain must be installed and tested exclusively by qualified automation personnel in strict accordance with local machinery directives.

1
Mounting and Mechanical Alignment: Fix the mounting brackets securely to a rigid frame. Ensure the emitter and receiver are parallel, with both top and bottom edges perfectly aligned. Check that the indicator LEDs are easily visible to the operator.
2
Electrical Connections: Connect the emitter and receiver cables to the control panel. Connect the dual PNP OSSD outputs directly to a safety monitoring relay or safety PLC input card. Do not parallel the two OSSD channels.
3
Optical Verification: Power up the unit and inspect the LEDs on the receiver. Adjust the physical alignment of the heads until the green alignment indicator lights consistently. Ensure no yellow or red diagnostic error states are active.
4
Commissioning Test: Use the standard 25 mm test piece to verify detection at multiple points along the light curtain path. Ensure that interrupting any part of the field immediately switches the safety outputs to the OFF state.
Loading product navigation…

What is the primary difference between the F3SJ-E and F3SJ-B series?

The F3SJ-E (Easy) is designed for simple, fixed-function applications without muting, blanking, or series-connection features, whereas the F3SJ-B offers basic parameter configurations and modular capabilities.

How do the PNP outputs of the F3SJ-E0625P25 operate?

The unit features two OSSD PNP semiconductor outputs that run self-diagnostics to detect short-circuits and cross-faults, shutting down immediately if an anomaly is identified.

Does this model support auxiliary outputs for external monitoring?

No, the F3SJ-E Easy Type does not include auxiliary outputs or external device monitoring (EDM). The safety relay or safety controller must manage feed-back monitoring independently.

What resolution detection does this safety light curtain provide?

This unit provides a 25 mm resolution (with a 20 mm beam gap), which is specifically rated for hand and arm protection zones.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Transformaram a Mineração Subterrânea

Desde compressores CC acionados por corda até carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como...