Omron G3PE-235B-3N G3PE Series 3-Phase Solid State Relay

Omron G3PE-235B-3N G3PE Series 3-Phase Solid State Relay

Apenas 3 item(ns) restante(s) em estoque
  • Fabricante: Omron

  • Nº do Produto: G3PE-235B-3N

  • País de origem:Japão

  • Tipo de Produto: 3-Phase Solid State Relays

  • Pagamento: T/T, Western Union

  • Peso: 500g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver informações completas

Description

Designed for high-frequency switching of industrial heating elements, the Omron G3PE-235B-3N provides robust 3-phase solid-state control with integrated zero-cross functionality. This solid-state contactor operates with a control input of 12 to 24 VDC and is engineered to switch rated loads up to 240 VAC at an output current of 35 A (at 40 degC ambient temperature). Utilizing phototriac isolation, the device isolates the low-voltage control circuitry from high-voltage transients on the load side, delivering highly reliable thermal management in demanding environments.

Features

  • Integrated heat sink optimizes thermal dissipation, maintaining performance at elevated ambient temperatures.
  • Built-in zero-cross circuit minimizes electromagnetic interference (EMI) and electrical noise during switching transitions.
  • Phototriac isolation provides 100% galvanic separation between input and output channels.
  • Screw terminal construction ensures secure, vibration-resistant terminations for high-current wiring.
  • DIN-rail and panel mounting configurations allow for flexible cabinet integration.

Applications

  • Industrial reflow ovens and packaging machinery heat-sealing bars.
  • Semiconductor manufacturing chamber and deposition heater controls.
  • Plastics extrusion, injection molding, and thermoforming equipment.
  • Environmental testing chambers and industrial climate control systems.

Technical Specifications

Manufacturer Omron
Model / SKU G3PE-235B-3N
Control Input Voltage 12 to 24 VDC
Operating Input Range 9.6 to 30 VDC
Input Current 10 mA max. (at 24 VDC)
Must Operate / Release Voltage 9.6 VDC max. / 1 VDC min.
Rated Load Voltage 100 to 240 VAC
Load Voltage Range 75 to 264 VAC
Load Current 35 A (at 40 degC ambient)
Minimum Load Current 0.5 A
Inrush Current Resistivity 440 A (60 Hz, 1 cycle)
Permissible I²t Value 1260 A²s
Applicable Load Capacity 12.1 kW (at 200 VAC)
Isolation Method Phototriac
Zero Cross Function Equipped
Terminal Structure Screw Terminal
Weight 3.0 kg

Connections and Interfaces

Terminal Group Designation Function / Connection Assignment
Input / Control Terminals A1 (+) Positive DC Control Input (12 to 24 VDC)
A2 (-) Negative DC Control Input (Common / Ground)
Output / Power Line Terminals L1 / L2 / L3 AC Line Inputs for Phase A, B, and C (100 to 240 VAC)
T1 / T2 / T3 AC Load Terminals outputting to heater/load circuits
Ground / PE Protective Earth ground terminal connected to the heat sink block

Empirical Engineering Insights

Alternative Models & Compatibility

The "3N" suffix specifies a model with a built-in heat sink and a 3-phase configuration without a built-in varistor. It directly replaces legacy G3PE configurations that match the 35 A current profile, but panel space requirements must be verified due to the integrated cooling profile. When migrating from 2-phase control systems (such as the G3PE-235B-2N) to 3-phase, ensure that your control PLC program and safety interlocks account for the switching of all three phases to optimize line balance and eliminate floating neutral potentials on delta-connected loads.

Application Pitfalls & Engineering Notes

Thermal derating is the primary failure vector in enclosed industrial cabinets. The 35 A rating is calculated at an ambient temperature of 40 degC or lower. If the internal panel ambient temperature rises to 60 degC, the maximum continuous load current must be derated by approximately 40%. Ensure a minimum vertical clearance of 80 mm and a horizontal clearance of 30 mm between the G3PE-235B-3N and surrounding hardware to maintain convection airflow through the heat sink fins.

Commissioning & Wiring Tips

To prevent localized high resistance and terminal charring, power terminals must be torqued precisely to 1.47 to 1.96 N-m using M5 terminal screws. Do not use tinned wire ends in screw clamp terminals; crimped pin terminals or ring lugs are highly recommended. If switching inductive heating elements rather than purely resistive loads, verify that the load inrush peak remains well within the 440 A (at 60 Hz) non-repetitive rating to prevent internal phototriac degradation.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE RISK

De-energize all 3-phase main power supply feeds and auxiliary control circuits before handling terminals or attempting mounting. Wait at least 5 minutes post de-energization to allow residual charges to bleed down. Verify zero voltage state using a calibrated multi-meter across all lines before executing wiring.

1
Mechanical Mount: Mount the device vertically on a standard 35mm DIN rail or directly to a backplane using the mounting screws. Ensure the cooling fins run vertically to facilitate natural convection.
2
Grounding: Connect the Protective Earth (PE) ground terminal of the heat sink assembly to the main panel grounding bus using a low-impedance copper conductor.
3
Input Wiring: Wire the 12 to 24 VDC control lines to the positive A1 and negative A2 terminals. Ensure polarity is maintained; incorrect polarity will prevent activation.
4
Load Wiring: Connect the 3-phase incoming lines to L1, L2, and L3, and the output heater lines to T1, T2, and T3. Verify that the load balance across all three legs does not exceed 35 A per phase.
Loading product navigation…

What is the purpose of the zero-cross function in the G3PE-235B-3N?

The zero-cross function ensures that the relay switches ON only when the AC load voltage is close to zero. This significantly reduces inrush currents, limits electrical transient noise, and minimizes electromagnetic interference (EMI) on nearby communication networks.

How does ambient temperature affect the current-carrying capacity of this solid-state relay?

The maximum rated current of 35 A is specified at an ambient temperature of 40 degC or below. Above 40 degC, the allowable load current decreases in accordance with the thermal derating curve of the device to prevent internal component damage.

Can the G3PE-235B-3N be used to switch inductive motor loads?

The G3PE-235B-3N is optimized for switching resistive heating loads (AC-51 duty). While it can switch inductive loads, inrush currents must be carefully calculated to ensure they do not exceed the non-repetitive surge rating of 440 A.

What is the recommended torque specification for the power terminal screws?

The power terminals use M5 screw sizes and must be tightened to a precise torque specification of 1.47 to 1.96 N-m to guarantee stable electrical contact and prevent thermal hot spots.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...