Omron G9SX-EX401-RT G9SX Series Flexible Safety Expansion Unit

Omron G9SX-EX401-RT G9SX Series Flexible Safety Expansion Unit

Apenas 5 item(ns) restante(s) em estoque
  • Fabricante: Omron

  • Nº do Produto: G9SX-EX401-RT

  • País de origem:Japão

  • Tipo de Produto: Safety Relay Expansion Modules

  • Pagamento: T/T, Western Union

  • Peso: 1500g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Integrating directly into master safety architectures, the Omron G9SX-EX401-RT expansion module expands the output capabilities of standard safety systems by providing additional instantaneous relay channels. Operating on a 24 VDC supply, this unit features 4 instantaneous safety outputs and 1 auxiliary feedback output, allowing industrial automation systems to scale safety-related control circuits without compromising response speed or diagnostic visibility. Designed with robust screw terminals, it ensures high vibration resistance and secure wiring connections in demanding industrial environments.

Key Features

  • Instantaneous Safety Expansion: Adds 4 highly reliable, instantaneous electromechanical safety outputs to a master controller.
  • Secure Inter-Unit Linking: Connects directly to G9SX-series master modules via safe logical connections.
  • Auxiliary Diagnostic Output: Features 1 auxiliary output for standard PLC monitoring and fault reporting.
  • Industrial-Grade Screw Terminals: RT-designated model incorporates heavy-duty screw terminals for robust field wiring.

Applications

  • Expansion of safety output circuits for light curtains, E-stop loops, and safety door switches.
  • Multi-zone safety system integration in high-capacity manufacturing lines.
  • Automated packaging systems requiring independent or grouped emergency stop zones.

Technical Specifications

Parameter Specification Value
Manufacturer Omron
Model Code G9SX-EX401-RT
Series G9SX Series
Device Type Flexible Safety Expansion Unit
Rated Supply Voltage 24 VDC
Operating Voltage Range -15% to 10% of rated supply voltage
Rated Power Consumption 2 W maximum
Safety Relay Outputs 4 instantaneous outputs (DPST-NO x 2)
Auxiliary Outputs 1 auxiliary semiconductor output
Rated Load 250 VAC, 3 A / 30 VDC, 3 A (resistive load)
Rated Carry Current 3 A
Operating Time (OFF to ON) 30 ms maximum
Response Time (ON to OFF) 10 ms maximum
Mechanical Durability 5,000,000 cycles minimum (switching frequency: 7,200 cycles/hour)
Electrical Durability 100,000 cycles minimum (rated load, switching frequency: 1,800 cycles/hour)
Terminal Type Screw terminals
Product Net Weight 0.165 kg
Shipping Weight (Calculated) 1.50 kg

Empirical Engineering Insights

Alternative Models & Compatibility

This expansion unit must always be matched with a master G9SX unit (e.g., G9SX-AD or G9SX-ADA series). It cannot operate as a standalone safety relay. When replacing older Omron safety expansion modules, verify terminal footprints; the RT model features screw terminals, which differ from spring-cage (RC) variants.

Application Pitfalls & Engineering Notes

When calculating the safety integrity level (SIL) and performance level (PL) for your safety loop, remember to add the 10 ms maximum response time of the expansion unit to the response time of your master G9SX unit. Ignoring this cumulative propagation delay can lead to insufficient safety distances for light curtains and emergency stop stations.

Commissioning & Wiring Tips

Ensure that the cross-unit connection cable is fully locked into place on both sides before applying 24 VDC control power. Powering the system up with a loose or partially inserted communication bus connector will cause the master module to enter a critical system fault mode, requiring a full power cycle to reset.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and auxiliary power sources before handling, mounting, or wiring this device. Failure to completely isolate power can result in electrical shock, unexpected machine startup, or irreversible damage to the internal safety relays.
1
Mount the expansion unit securely onto a standard 35 mm DIN rail immediately adjacent to the master G9SX safety unit.
2
Connect the lateral expansion bus connector from the master controller to the side socket of the expansion unit until it clicks firmly into place.
3
Wire the 24 VDC power supply terminals and individual safety outputs, ensuring that all screw terminals are torqued according to OEM specifications.
Loading product navigation…

Can the G9SX-EX401-RT function as a standalone safety relay?

No. The G9SX-EX401-RT is an expansion module and requires a compatible G9SX master safety controller to provide safety logic processing and power.

What is the differences between the RT and RC models in this series?

The RT version is equipped with standard screw terminal blocks, whereas the RC version features spring-cage tension terminals for toolless wiring.

How does this expansion unit affect the system safety response time?

The G9SX-EX401-RT adds a maximum response time of 10 ms (ON to OFF) which must be added to the response time of the master safety unit for system-wide safety distance calculations.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...