Description

Direct human-machine interface interaction is established through the Omron NS5-MQ11-V2, a reliable monochrome terminal engineered for integration within the Omron NS Series architecture. This unit provides a highly functional visual interface for machine-level monitoring and control, housing a robust display in a durable panel-mount form factor. Configured with dual RS-232C ports, it coordinates seamless communication with host PLCs, temperature controllers, and auxiliary devices. Designed for operational longevity, this model features an ivory bezel that integrates cleanly with classic industrial control cabinets.

Features

  • Monochrome STN Display: Offers clear legibility for alarms, status registers, and process variables at a standard 320 x 240 pixel resolution.
  • Dual Serial Connectivity: Features two independent RS-232C interfaces for multi-device or dual-protocol configurations.
  • Dedicated Programming Interface: Integrated USB slave port allows high-speed screen data transfer and debugging directly from CX-Designer.
  • Memory Expansion Slot: Rear-accessible slot supports standard CompactFlash cards for backup, data logging, and system firmware updates.
  • High-Durability Bezel: IP65F front-panel rating provides robust protection against ingress of moisture and fine particulate matter in harsh environments.

Applications

  • Packaging Machinery: Local machine control panels requiring fast screens, recipe modification, and alarm status tracking.
  • Material Handling: Monitoring conveyor speeds, diverter status, and sorting criteria on localized nodes.
  • Process Subsystems: Interface terminal for localized water treatment, environmental chambers, or basic raw material dosing units.

Technical Specifications

Manufacturer Omron
Model Reference NS5-MQ11-V2
Series NS Series
Display Type STN Monochrome LCD
Display Size 5.7 inches
Resolution 320 x 240 pixels (QVGA)
Input Voltage 24 VDC (Acceptable range: 20.4 to 27.6 VDC)
Power Consumption 15 Watts maximum
Serial Communications 2x RS-232C Ports
USB Ports 1x USB Type-B Slave (USB 1.1)
Case Color Ivory
Operating Temperature 0 to 50 degC
Front Panel Protection IP65F equivalent
Country of Origin Japan
Shipping Weight (Calculated) 1.5 kg
Package Dimensions (Calculated) 24.5 cm x 19.2 cm x 8.5 cm

Connections and Interfaces

Port Reference Connector Type Functional Assignment / Signal Mapping
Serial Port A D-Sub 9-pin Female Host Link / NT Link RS-232C serial connection to PLC CPU.
Serial Port B D-Sub 9-pin Female Auxiliary serial communications (RS-232C), peripheral devices, or temperature controllers.
USB Tool Port USB Type-B (Slave) Dedicated interface for high-speed programming, screen downloads, and online system debugging.
Power Input Terminal M3.5 Screw Terminal Block 24 VDC Power Input along with functional ground (FG) terminal for noise abatement.

Empirical Engineering Insights

Alternative Models & Compatibility

The "V2" suffix represents upgraded internal processing and expanded compatibility with newer runtime versions compared to legacy V1 variants. Note that the NS5-MQ11-V2 (Ivory bezel) is chemically and structurally identical in internal operation to the NS5-MQ11B-V2 (Black bezel), permitting direct drop-in substitution when bezel aesthetics are not critical. Software configuration projects built in CX-Designer can target either color variant without modification.

Application Pitfalls & Engineering Notes

Because this unit utilizes a monochrome STN LCD, viewing angles and response latency can be more pronounced compared to modern TFT equivalents. When designing HMI screens, maintain high-contrast graphic layouts (solid black/white configurations rather than gradient shades) to preserve visibility in direct plant floor lighting. Ensure the rear ventilation slot is unblocked; operation inside enclosures exceeding 50 degC will significantly accelerate CCFL backlight degradation.

Commissioning & Wiring Tips

To protect against communication time-outs and localized ground loop disruption, dedicated 24 VDC supply routing is recommended. Keep serial RS-232C lines isolated from high-voltage motor starters and variable frequency drive cables. Always verify the functional ground terminal is tied back to a solid low-impedance earth connection using a wire size of at least 2.0 mm².

Installation Guidelines

CRITICAL WARNING

Isolate and verify de-energization of the primary power supply source before working on the 24 VDC terminals. Do not service the power connector, change the system configuration, or adjust wiring while voltage is applied to avoid physical shock or severe control system damage.

1 Ensure the panel cutout dimensions conform exactly to the physical specs of 184 mm x 131 mm.
2 Seat the waterproofing gasket completely around the inner bezel lip before inserting the unit into the cutout.
3 Tighten the included mounting brackets evenly to a torque of 0.5 to 0.6 N-m to achieve a proper IP65F seal without cracking the bezel.
4 Terminate the 24 VDC power lines using insulated crimp terminals on the M3.5 screws. Ensure polarity is strictly maintained.
Loading product navigation…

What is the structural difference between the NS5-MQ11-V2 and the NS5-MQ11B-V2?

The only difference is the physical enclosure color. The NS5-MQ11-V2 has an ivory-colored front bezel, whereas the NS5-MQ11B-V2 has a black bezel. Internally, all electrical specifications, software requirements, and communications are identical.

Can I program the NS5-MQ11-V2 via an Ethernet connection?

No, the NS5-MQ11-V2 is a serial-only base terminal. Screen transfer and firmware operations must be performed using either the dedicated USB slave port connected directly to a PC running CX-Designer, or via a formatted CompactFlash card in the expansion slot.

Does this model support direct NT Link communications?

Yes. Both integrated serial ports support high-speed 1:1 and 1:N NT Link protocols, alongside Host Link, for seamless data exchange with compatible Omron Sysmac PLCs.

What software is used to design and download screens for this HMI?

The Omron NS5-MQ11-V2 is configured using the CX-Designer software, which is part of the comprehensive CX-One software suite. It is highly recommended to use CX-Designer version 3.0 or higher.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...