Omron NS5-TQ10B-ECV2 NS-Series Programmable Terminal

Omron NS5-TQ10B-ECV2 NS-Series Programmable Terminal

Apenas 5 item(ns) restante(s) em estoque
  • Fabricante: Omron

  • Nº do Produto: NS5-TQ10B-ECV2

  • País de origem:Japão

  • Tipo de Produto: HMI Operator Terminals

  • Pagamento: T/T, Western Union

  • Peso: 8000g

  • Dimensões: 245 x 195 x 110 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Engineered for distributed machine-level monitoring, the Omron NS5-TQ10B-ECV2 serves as a centralized operator control interface within the premium NS-Series platform. This hardware terminal combines a vibrant 5.7-inch High-Luminance TFT Color LCD with robust communication capabilities, incorporating an integrated 10Base-T Ethernet port and dual serial transceivers. Operating on a standard 24 VDC input, the terminal is designed to withstand harsh factory environments, featuring an IP65f front-face rating and a resilient black protective bezel. With 60 MB of internal memory, it supports complex graphic representations, high-density alarm logging, and seamless CX-Designer configuration integration.

Features

  • High-visibility TFT display supporting up to 32,768 colors for realistic CAD-based machine graphics.
  • Built-in Ethernet port enabling FTP server capabilities, data transfers, and remote monitoring over TCP/IP.
  • Dual independent RS-232C serial ports for direct, simultaneous connections to PLCs, temperature controllers, and barcode readers.
  • Extensive 60 MB memory allocation for substantial screen data storage, system recipes, and historic trend logs.
  • High-durability LED backlight providing long-term illumination consistency without the degradation risks of legacy CCFL lamps.

Applications

  • Automated packaging and cartoning machinery line integration.
  • Pumping stations and local water treatment HMI monitoring panels.
  • Automotive component assembly verification and testing cells.
  • Discrete material handling and sorting system visualization.

Technical Specifications Table

Parameter Specification Value
Manufacturer Omron
Model Number NS5-TQ10B-ECV2
Display Type 5.7-inch High-Luminance TFT Color LCD
Resolution 320 x 240 pixels (QVGA)
Backlight LED (non-replaceable, service life approx. 50,000 hours)
Input Voltage 24 VDC (Acceptable range: 20.4 to 27.6 VDC)
Power Consumption 15 W maximum
Onboard Ethernet 1x RJ-45 Port (10Base-T)
Serial Communications 2x RS-232C Ports (D-sub 9-pin female)
USB Interfaces 1x USB Type B Slave (for programming download)
Internal Project Memory 60 MB Flash Memory
Enclosure Bezel Color Black
Protection Rating IP65f (front panel, panel-mounted)
Operating Temperature 0 to 50 degC
Shipping Weight (Calculated) 1.85 kg
Package Dimensions (Calculated) 245 x 195 x 110 mm

Connections and Interfaces

Port / Terminal Block Physical Form Signal Assignment & Pin Function
Serial Port A (CN1) D-sub 9-pin Female Host Link / NT Link RS-232C communication channel 1
Serial Port B (CN2) D-sub 9-pin Female Host Link / NT Link RS-232C communication channel 2
Ethernet RJ-45 10Base-T network interface (FTP, screen data transfer, FINS communications)
USB (Slave) USB Type B Connection to CX-Designer programming PC for screen development and diagnostics
Power Input M3 Screw Terminals Pin 1: +24 VDC | Pin 2: 0 VDC | Pin 3: Functional Ground (FG)

Empirical Engineering Insights

Alternative Models & Compatibility

The "ECV2" revision represents a major evolutionary step over older NS5-TQ10B-V2 units. The critical distinction lies in the backlight design: the ECV2 employs an integrated solid-state LED configuration, whereas earlier legacy units utilized CCFL tubes driven by high-voltage internal inverters. Project databases generated for older NS5 versions can be converted to run on the ECV2 unit via CX-Designer; simply update the destination hardware designation inside the system properties before transferring. Be aware that color rendering profiles may differ slightly due to the shift from CCFL to LED emission spectrums.

Application Pitfalls & Engineering Notes

Touch-screen matrix degradation is a common physical failure point if these terminals are installed in close proximity to radiant heat sources. While the unit functions up to 50 degC, prolonged internal temperatures exceeding 45 degC inside non-ventilated enclosures can lead to local delamination of the resistive overlay. For panels where ambient internal heat is a constant factor, we recommend installing low-draw convective air systems or cooling fans, maintaining a mandatory 100 mm clearing around the backplate air vents.

Commissioning & Wiring Tips

To prevent grounding-loop failures across serial pathways, ensure the functional ground terminal (FG) is tied back to the main cabinet star-ground point via a heavy-gauge (minimum 2 mm²) stranded green wire. When implementing RS-232C communication lines to CS/CJ-series PLCs, always utilize double-shielded twisted pairs and ground the cable shield on the PLC chassis side only. This layout successfully diverts high-frequency industrial noise away from the NS5 transceiver chips, avoiding intermittent "HMI Communication Timeouts" errors.

Installation Guidelines

CRITICAL WARNING: Isolate the 24 VDC supply and de-energize the entire control panel prior to attempting HMI physical mounting or electrical termination. Executing wiring procedures while power is active can induce voltage spikes, causing permanent logic board destruction.
1
Ensure the panel cutout dimensions measure exactly 184.0 mm (+0.5/-0 mm) wide by 131.0 mm (+0.5/-0 mm) high to achieve an optimal environmental seal.
2
Check that the waterproof rubber sealing gasket is seated uniformly in the front-bezel groove before inserting the HMI terminal into the cutout.
3
Secure the unit into the panel using the provided metal mounting clamps. Tighten the clamping screws evenly to a target torque of 0.5 to 0.6 N-m; over-torqueing may warp the plastic bezel, ruining the IP65f seal.
4
Terminate the 24 VDC lines to the power terminal block, verifying polarity matches the marked terminals before switching on the power.
Loading product navigation…

What is the primary technical difference between the ECV2 and the standard V2 NS5 models?

The ECV2 model incorporates an integrated LED backlight and built-in 10Base-T Ethernet, replacing the CCFL backlights used in standard V2 units, which reduces thermal output and increases operational lifespan.

Does this operator terminal support expansion communication boards?

Yes, the NS5 features a backplate expansion slot that allows the installation of Controller Link or other option boards to integrate with existing network architectures.

Can I download projects to the NS5 terminal without using the USB port?

Yes, screen projects can be transferred directly over the network using the built-in Ethernet interface, or physically using a standard Memory Card in the integrated slot.

What software package is required to configure the screen graphics for this HMI?

Omron CX-Designer, which is part of the comprehensive CX-One software suite, is the native utility used to configure and program the NS-Series terminals.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...