1 de 1

Omron NX-AD2608 NX Series Analog Input Unit

Omron NX-AD2608 NX Series Analog Input Unit

Apenas 4 item(ns) restante(s) em estoque
  • Fabricante: Omron

  • Nº do Produto: NX-AD2608

  • País de origem:Japão

  • Tipo de Produto: Analog Input Modules

  • Pagamento: T/T, Western Union

  • Peso: 70g

  • Dimensões: 12 mm x 100 mm x 71 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed for high-speed and high-precision data acquisition within industrial automation systems, the Omron NX-AD2608 is a high-performance analog input module featuring 2 differential voltage input channels. Operating within the Sysmac platform, this module converts external analog voltage signals ranging from -10 V to +10 V into high-resolution digital values. With a conversion rate of 10 microseconds per point and a high resolution of 1/30000, it is engineered for applications demanding tight process control and rapid response times.

The Omron NX-AD2608 supports switching between synchronous I/O refreshing and Free-Run refreshing, allowing precise synchronization with the controller CPU or communications coupler unit. The module features a compact, space-saving design with a width of just 12 mm, and integrates a screwless clamping terminal block for fast, reliable wiring in high-vibration environments.

Features

  • Two independent differential voltage input channels with a range of -10 to +10 V.
  • Exceptional conversion speed of 10 us per point for high-speed automation loop responsiveness.
  • High measurement resolution of 1/30000 for precise feedback.
  • Flexible I/O refreshing methods: Switching synchronous I/O refreshing and Free-Run refreshing.
  • Integrated screwless clamping terminal block (8 terminals) for simplified wiring and maintenance.
  • Robust isolation via transformer (power) and digital isolator (signal) between inputs and the NX bus.
  • Status indication via a dedicated TS indicator on the front panel.

Applications

  • High-speed motion control and servo system feedback loops.
  • Factory automation and packaging machinery.
  • Precision temperature, pressure, or flow monitoring systems.
  • Data logging and process monitoring in manufacturing lines.

Technical Specifications

Parameter Specification
Manufacturer Omron
Part Number / Model NX-AD2608
Product Type Analog Input Unit (Voltage)
Number of Points 2 inputs
Input Range -10 to +10 V
Input Method Differential input
Resolution 1/30000
Conversion Time 10 us per point
Input Conversion Range -5% to 105% (full scale)
Absolute Maximum Rating +/-15 V
Input Impedance 1 MOhm min.
Overall Accuracy at 25 degC +/-0.1% (full scale)
Overall Accuracy at 0 to 55 degC +/-0.2% (full scale)
I/O Refreshing Method Switching synchronous I/O refreshing / Free-Run refreshing
Isolation Method Between input and NX bus: Transformer (Power), Digital isolator (Signal). No isolation between inputs.
Insulation Resistance 20 MOhm min. between isolated circuits (at 100 VDC)
Dielectric Strength 510 VAC between isolated circuits for 1 minute (leakage current 5 mA max.)
I/O Power Supply Method No supply
NX Unit Power Consumption Connected to CPU/Communication Control Unit: 1.35 W max.
Connected to Communications Coupler Unit: 1.05 W max.
Dimensions (W x H x D) 12 mm x 100 mm x 71 mm
Weight 0.07 kg

Installation Guidelines

  • Mounting: Mount the unit onto a standard 35 mm DIN rail. Ensure the unit clicks securely into place alongside adjacent NX-series I/O modules.
  • Wiring: Use solid wires or stranded wires with ferrules. Insert the wire directly into the screwless clamping terminal block without the use of tools. To remove, press the release button with a flat-head screwdriver.
  • Noise Mitigation: Utilize shielded twisted-pair cables for analog input lines. Keep signal wiring separated from high-voltage power lines and motor drive cables to prevent electromagnetic interference.
  • Grounding: Ensure the functional ground terminal on the DIN rail is properly grounded according to local industrial electrical codes.
Loading product navigation…

What is the input range of the Omron NX-AD2608 module?

The Omron NX-AD2608 supports a differential voltage input range of -10 V to +10 V.

What is the conversion speed and resolution of the NX-AD2608?

The module features a high-speed conversion rate of 10 microseconds per point and a resolution of 1/30000.

Is there electrical isolation between the inputs on this unit?

No, there is no isolation between the individual input channels. However, there is isolation (via transformer for power and digital isolator for signals) between the inputs and the NX bus.

What connection terminal type is used on the NX-AD2608?

It features an 8-terminal screwless clamping terminal block for fast and reliable wiring.

Does the NX-AD2608 require an external I/O power supply?

No, the module does not require or consume power from an external I/O power supply terminal; it is powered via the NX bus.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...